Source author record

Jonathan Correa

Jonathan Correa appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2021arXiv

Single-shot MHz velocity-map-imaging using two Timepix3 cameras

We demonstrate the application of event-driven Timepix3-based detectors in combination with a double-sided velocity-map-imaging spectrometer to record the full 3D momentum of charged particles at the free-electron-laser facility FLASH. We measured the XUV induced fragmentation of $\text{N}_2$ using 250 kHz FLASH bursts with sub-pixel spatial resolution and up to 1.7~ns temporal resolution for photoelectrons. To further demonstrate the capabilities of this camera at even higher repetition rates we measured single-shot images of He($1s$) photoelectrons for bursts with a repetition rate of 1 MHz. Overall, with the Timepix3 camera we overcome limitations of standard-camera technology for advanced-imaging experiments with requirements on high event-rates and high spatio-temporal resolution.

preprint2019arXiv

PymePix: A python library for SPIDR readout of Timepix3

PymePix is a new Python 3 library that provides control and acquisition for the Timepix3-SPIDR hardware. The rich set of data-structures and intuitive routines reduces time and coding effort to quickly configure, acquire, and visualize data from Timepix3. The highly extensible high-performance data-pipeline allows for alteration of the Timepix3 datastream into a form that is convinient for the user. This library is intended to be easily inserted into a standard scientific software stack as well as to allow for more direct interaction of Timepix3 with interactive flavors of Python. Included with the library are two example programs using PymePix: pymepix-acq is a command line control and acquisition program that can capture UDP packets and decode them into pixels and triggers. The second is PymePix-Viewer, an online control and data-acquisition program for general use, but with features geared toward mass-spectroscopy and ion imaging.

preprint2013arXiv

Investigation of gamma-ray sensitivity of neutron detectors based on thin converter films

Currently, many detector technologies for thermal neutron detection are in development in order to lower the demand for the rare 3He gas. Gas detectors with solid thin film neutron converters readout by gas proportional counter method have been proposed as an appropriate choice for applications where large area coverage is necessary. In this paper, we investigate the probability for gamma-rays to generate a false count in a neutron measurement. Simulated results are compared to measurement with a 10B thin film prototype and a 3He detector. It is demonstrated that equal gamma-ray rejection to that of 3He tubes is achieved with the new technology. The arguments and results presented here are also applicable to gas detectors with converters other than solid 10B layers, such as 6Li layers and 10BF3 gas.

preprint2012arXiv

Multi-Grid Boron-10 detector for large area applications in neutron scattering science

The present supply of 3He can no longer meet the detector demands of the upcoming ESS facility and continued detector upgrades at current neutron sources. Therefore viable alternative technologies are required to support the development of cutting-edge instrumentation for neutron scattering science. In this context, 10B-based detectors are being developed by collaboration between the ESS, ILL, and Linköping University. This paper reports on progress of this technology and the prospects applying it in modern neutron scattering experiments. The detector is made-up of multiple rectangular gas counter tubes coated with B4C, enriched in 10B. An anode wire reads out each tube, thereby giving position of conversion in one of the lateral co-ordinates as well as in depth of the detector. Position resolution in the remaining co-ordinate is obtained by segmenting the cathode tube itself. Boron carbide films have been produced at Linköping University and a detector built at ILL. The characterization study is presented in this paper, including measurement of efficiency, effects of the fill gas species and pressure, coating thickness variation on efficiency and sensitivity to gamma-rays.