Source author record

David Pennicard

David Pennicard appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2021arXiv

Single-shot MHz velocity-map-imaging using two Timepix3 cameras

We demonstrate the application of event-driven Timepix3-based detectors in combination with a double-sided velocity-map-imaging spectrometer to record the full 3D momentum of charged particles at the free-electron-laser facility FLASH. We measured the XUV induced fragmentation of $\text{N}_2$ using 250 kHz FLASH bursts with sub-pixel spatial resolution and up to 1.7~ns temporal resolution for photoelectrons. To further demonstrate the capabilities of this camera at even higher repetition rates we measured single-shot images of He($1s$) photoelectrons for bursts with a repetition rate of 1 MHz. Overall, with the Timepix3 camera we overcome limitations of standard-camera technology for advanced-imaging experiments with requirements on high event-rates and high spatio-temporal resolution.

preprint2019arXiv

PymePix: A python library for SPIDR readout of Timepix3

PymePix is a new Python 3 library that provides control and acquisition for the Timepix3-SPIDR hardware. The rich set of data-structures and intuitive routines reduces time and coding effort to quickly configure, acquire, and visualize data from Timepix3. The highly extensible high-performance data-pipeline allows for alteration of the Timepix3 datastream into a form that is convinient for the user. This library is intended to be easily inserted into a standard scientific software stack as well as to allow for more direct interaction of Timepix3 with interactive flavors of Python. Included with the library are two example programs using PymePix: pymepix-acq is a command line control and acquisition program that can capture UDP packets and decode them into pixels and triggers. The second is PymePix-Viewer, an online control and data-acquisition program for general use, but with features geared toward mass-spectroscopy and ion imaging.

preprint2014arXiv

Optimization of radiation hardness and charge collection of edgeless silicon pixel sensors for photon science

Recent progress in active-edge technology of silicon sensors enables the development of large-area tiled silicon pixel detectors with small dead space between modules by utilizing edgeless sensors. Such technology has been proven in successful productions of ATLAS and Medipix-based silicon pixel sensors by a few foundries. However, the drawbacks of edgeless sensors are poor radiation hardness for ionizing radiation and non-uniform charge collection by edge pixels. In this work, the radiation hardness of edgeless sensors with different polarities has been investigated using Synopsys TCAD with X-ray radiation-damage parameters implemented. Results show that if no conventional guard ring is present, none of the current designs are able to achieve a high breakdown voltage (typically < 30 V) after irradiation to a dose of ~10 MGy. In addition, a charge-collection model has been developed and was used to calculate the charges collected by the edge pixels of edgeless sensors when illuminated with X-rays. The model takes into account the electric field distribution inside the pixel sensor, the absorption of X-rays, drift and diffusion of electrons and holes, charge sharing effect, and threshold settings in ASICs. It is found that the non-uniform charge collection of edge pixels is caused by the strong bending of electric field and the non-uniformity depends on bias voltage, sensor thickness and distance from active edge to the last pixel ("edge space"). In particular, the last few pixels close to the active edge of the sensor are not sensitive to low-energy X-rays (< 10 keV) especially for sensors with thicker Si and smaller edge space. The results from the model calculation have been compared to measurements and good agreement was obtained. The model has been used to optimize the edge design.