Researcher profile

Jonas Graetz

Jonas Graetz contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2021arXiv

A Novel Nano Tomography Setup for Material Science and Engineering Applications

In a comprehensive study on several samples we demonstrate for our laboratory-based computed tomography system resolutions down to 150nm. The achieved resolution is validated by imaging com-mon test structures in 2D and Fourier Shell Correlation of 3D volumes. As representative application examples from nowadays material research, we show metallization processes in multilayer integrated circuits, ageing in lithium battery electrodes, and volumetric of metallic sub-micrometer fillers of com-posites. Thus, our laboratory system provides the unique possibility to image non-destructively struc-tures in the range of hundred nanometers, even for high density materials.

preprint2020arXiv

High performance volume ray casting: A branchless generalized Joseph projector

A concise and highly performant branchless formulation of a Joseph-type interpolating ray-casting algorithm for the computation of X-ray projections is presented. It efficiently utilizes the hardware resources of modern graphics processing units at the scale of their theoretic maximum performance reaching access rates of 600 GB/s within read-and-write memory, and is further shown to do so without compromising on image quality. The computation of X-ray projections from discrete voxel grids is an ubiquitous task in many problems related to volume image processing, including tomographic reconstruction and visualization. Although its central role has given rise to numerous publications discussing the optimal modeling of ray-volume intersections, a unique benchmark in this respect does not exist. Here, a 3D Shepp-Logan phantom is used, which allows the computation of analytic reference projections that can further serve as input to iterative reconstructions without committing the inverse crime. The proposed algorithm (GJP) is compared to the competing and widely adopted digital differential analyzer (DDA), which computes exact line-box intersections. It is thereby found to outperform the DDA on recent graphics processors in all respects: Despite accessing twice as much memory, the GJP is still able to calculate projections twice as fast. It further exhibits considerably less discretization artifacts, and neither oversampling of the DDA nor a smooth interpolation kernel within the GJP are able to improve on these results in any respect.

preprint2020arXiv

Lenseless X-ray Nano-Tomography down to 150nm Resolution: On the Quantification of Modulation Transfer and Focal Spot of the Lab-based ntCT System

The ntCT nano tomography system is a geometrically magnifying X-ray microscopy system integrating the recent Excillum NanoTube nano-focus X-ray source and a CdTe photon counting detector from Dectris. The system's modulation transfer function (MTF) and corresponding point spread function (PSF) are characterized by analyzing the contrast visibility of periodic structures of a star pattern featuring line width from 150nm to 1.5$μ$m. The results, which can be attributed to the characteristics of the source spot, are crosschecked by scanning the source's electron focus over an edge of the structured transmission target in order to obtain an independent measurement of its point spread function. For frequencies above 1000 linepairs/mm, the MTF is found to correspond to a Gaussian PSF of 250nm full width at half maximum (FWHM). The lower frequency range down to 340 linepairs/mm shows an additional Gaussian contribution of 1$μ$m FWHM. The resulting resolution ranges at 3200 linepairs/mm, which is consistent with the visual detectability of the smallest 150nm structures within the imaged star pattern.

preprint2020arXiv

Review and experimental verification of X-ray darkfield signal interpretations with respect to quantitative isotropic and anisotropic darkfield computed tomography

Talbot(-Lau) interferometric X-ray darkfield imaging has, over the past decade, gained substantial interest for its ability to provide insights into a sample's microstructure below the imaging resolution by means of ultra small angle scattering effects. Quantitative interpretations of such images depend on models of the signal origination process that relate the observable image contrast to underlying physical processes. A review of such models is given here and their relation to the wave optical derivations by Yashiro et al. and Lynch et al. as well as to small angle X-ray scattering is discussed. Fresnel scaling is introduced to explain the characteristic distance dependence observed in cone beam geometries. Moreover, a model describing the anisotropic signals of fibrous objects is derived. The Yashiro-Lynch model is experimentally verified both in radiographic and tomographic imaging in a monochromatic synchrotron setting, considering both the effects of material and positional dependence of the resulting darkfield contrast. The effect of varying sample-detector distance on the darkfield signal is shown to be non-negligible for tomographic imaging, yet can be largely compensated for by symmetric acquisition trajectories. The derived orientation dependence of the darkfield contrast of fibrous materials both with respect to variations in autocorrelation width and scattering cross section is experimentally validated using carbon fiber reinforced rods.