Researcher profile

Dominik Müller

Dominik Müller contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
9works
0followers
9topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2022arXiv

An Analysis on Ensemble Learning optimized Medical Image Classification with Deep Convolutional Neural Networks

Novel and high-performance medical image classification pipelines are heavily utilizing ensemble learning strategies. The idea of ensemble learning is to assemble diverse models or multiple predictions and, thus, boost prediction performance. However, it is still an open question to what extent as well as which ensemble learning strategies are beneficial in deep learning based medical image classification pipelines. In this work, we proposed a reproducible medical image classification pipeline for analyzing the performance impact of the following ensemble learning techniques: Augmenting, Stacking, and Bagging. The pipeline consists of state-of-the-art preprocessing and image augmentation methods as well as 9 deep convolution neural network architectures. It was applied on four popular medical imaging datasets with varying complexity. Furthermore, 12 pooling functions for combining multiple predictions were analyzed, ranging from simple statistical functions like unweighted averaging up to more complex learning-based functions like support vector machines. Our results revealed that Stacking achieved the largest performance gain of up to 13% F1-score increase. Augmenting showed consistent improvement capabilities by up to 4% and is also applicable to single model based pipelines. Cross-validation based Bagging demonstrated significant performance gain close to Stacking, which resulted in an F1-score increase up to +11%. Furthermore, we demonstrated that simple statistical pooling functions are equal or often even better than more complex pooling functions. We concluded that the integration of ensemble learning techniques is a powerful method for any medical image classification pipeline to improve robustness and boost performance.

preprint2022arXiv

Characterizing the aerosol atmosphere above the Observatorio del Roque de los Muchachos by analyzing seven years of data taken with an GaAsP HPD-readout, absolutely calibrated elastic LIDAR

We present a new elastic LIDAR concept, based on a bi-axially mounted Nd:YAG laser and a telescope with HPD readout, combined with fast FADC signal digitization and offline pulse analysis. The LIDAR return signals have been extensively quality checked and absolutely calibrated. We analyze seven years of quasi-continuous LIDAR data taken during those nights when the MAGIC telescopes were operating. Characterization of the nocturnal ground layer yields zenith and azimuth angle dependent aerosol extinction scale heights for clear nights. We derive aerosol transmission statistics for light emitted from various altitudes throughout the year and separated by seasons. We find further seasonal dependencies of cloud base and top altitudes, but none for the LIDAR ratios of clouds. Finally, the night sky background light is characterized using the LIDAR photon backgrounds. abstract.txt

preprint2022arXiv

MISeval: a Metric Library for Medical Image Segmentation Evaluation

Correct performance assessment is crucial for evaluating modern artificial intelligence algorithms in medicine like deep-learning based medical image segmentation models. However, there is no universal metric library in Python for standardized and reproducible evaluation. Thus, we propose our open-source publicly available Python package MISeval: a metric library for Medical Image Segmentation Evaluation. The implemented metrics can be intuitively used and easily integrated into any performance assessment pipeline. The package utilizes modern CI/CD strategies to ensure functionality and stability. MISeval is available from PyPI (miseval) and GitHub: https://github.com/frankkramer-lab/miseval.

preprint2022arXiv

Perspective on Code Submission and Automated Evaluation Platforms for University Teaching

We present a perspective on platforms for code submission and automated evaluation in the context of university teaching. Due to the COVID-19 pandemic, such platforms have become an essential asset for remote courses and a reasonable standard for structured code submission concerning increasing numbers of students in computer sciences. Utilizing automated code evaluation techniques exhibits notable positive impacts for both students and teachers in terms of quality and scalability. We identified relevant technical and non-technical requirements for such platforms in terms of practical applicability and secure code submission environments. Furthermore, a survey among students was conducted to obtain empirical data on general perception. We conclude that submission and automated evaluation involves continuous maintenance yet lowers the required workload for teachers and provides better evaluation transparency for students.

preprint2022arXiv

Towards a Guideline for Evaluation Metrics in Medical Image Segmentation

In the last decade, research on artificial intelligence has seen rapid growth with deep learning models, especially in the field of medical image segmentation. Various studies demonstrated that these models have powerful prediction capabilities and achieved similar results as clinicians. However, recent studies revealed that the evaluation in image segmentation studies lacks reliable model performance assessment and showed statistical bias by incorrect metric implementation or usage. Thus, this work provides an overview and interpretation guide on the following metrics for medical image segmentation evaluation in binary as well as multi-class problems: Dice similarity coefficient, Jaccard, Sensitivity, Specificity, Rand index, ROC curves, Cohen's Kappa, and Hausdorff distance. As a summary, we propose a guideline for standardized medical image segmentation evaluation to improve evaluation quality, reproducibility, and comparability in the research field.

preprint2021arXiv

A Novel Nano Tomography Setup for Material Science and Engineering Applications

In a comprehensive study on several samples we demonstrate for our laboratory-based computed tomography system resolutions down to 150nm. The achieved resolution is validated by imaging com-mon test structures in 2D and Fourier Shell Correlation of 3D volumes. As representative application examples from nowadays material research, we show metallization processes in multilayer integrated circuits, ageing in lithium battery electrodes, and volumetric of metallic sub-micrometer fillers of com-posites. Thus, our laboratory system provides the unique possibility to image non-destructively struc-tures in the range of hundred nanometers, even for high density materials.

preprint2020arXiv

Automated Chest CT Image Segmentation of COVID-19 Lung Infection based on 3D U-Net

The coronavirus disease 2019 (COVID-19) affects billions of lives around the world and has a significant impact on public healthcare. Due to rising skepticism towards the sensitivity of RT-PCR as screening method, medical imaging like computed tomography offers great potential as alternative. For this reason, automated image segmentation is highly desired as clinical decision support for quantitative assessment and disease monitoring. However, publicly available COVID-19 imaging data is limited which leads to overfitting of traditional approaches. To address this problem, we propose an innovative automated segmentation pipeline for COVID-19 infected regions, which is able to handle small datasets by utilization as variant databases. Our method focuses on on-the-fly generation of unique and random image patches for training by performing several preprocessing methods and exploiting extensive data augmentation. For further reduction of the overfitting risk, we implemented a standard 3D U-Net architecture instead of new or computational complex neural network architectures. Through a 5-fold cross-validation on 20 CT scans of COVID-19 patients, we were able to develop a highly accurate as well as robust segmentation model for lungs and COVID-19 infected regions without overfitting on the limited data. Our method achieved Dice similarity coefficients of 0.956 for lungs and 0.761 for infection. We demonstrated that the proposed method outperforms related approaches, advances the state-of-the-art for COVID-19 segmentation and improves medical image analysis with limited data. The code and model are available under the following link: https://github.com/frankkramer-lab/covid19.MIScnn

preprint2020arXiv

Lenseless X-ray Nano-Tomography down to 150nm Resolution: On the Quantification of Modulation Transfer and Focal Spot of the Lab-based ntCT System

The ntCT nano tomography system is a geometrically magnifying X-ray microscopy system integrating the recent Excillum NanoTube nano-focus X-ray source and a CdTe photon counting detector from Dectris. The system's modulation transfer function (MTF) and corresponding point spread function (PSF) are characterized by analyzing the contrast visibility of periodic structures of a star pattern featuring line width from 150nm to 1.5$μ$m. The results, which can be attributed to the characteristics of the source spot, are crosschecked by scanning the source's electron focus over an edge of the structured transmission target in order to obtain an independent measurement of its point spread function. For frequencies above 1000 linepairs/mm, the MTF is found to correspond to a Gaussian PSF of 250nm full width at half maximum (FWHM). The lower frequency range down to 340 linepairs/mm shows an additional Gaussian contribution of 1$μ$m FWHM. The resulting resolution ranges at 3200 linepairs/mm, which is consistent with the visual detectability of the smallest 150nm structures within the imaged star pattern.

preprint2019arXiv

MIScnn: A Framework for Medical Image Segmentation with Convolutional Neural Networks and Deep Learning

The increased availability and usage of modern medical imaging induced a strong need for automatic medical image segmentation. Still, current image segmentation platforms do not provide the required functionalities for plain setup of medical image segmentation pipelines. Already implemented pipelines are commonly standalone software, optimized on a specific public data set. Therefore, this paper introduces the open-source Python library MIScnn. The aim of MIScnn is to provide an intuitive API allowing fast building of medical image segmentation pipelines including data I/O, preprocessing, data augmentation, patch-wise analysis, metrics, a library with state-of-the-art deep learning models and model utilization like training, prediction, as well as fully automatic evaluation (e.g. cross-validation). Similarly, high configurability and multiple open interfaces allow full pipeline customization. Running a cross-validation with MIScnn on the Kidney Tumor Segmentation Challenge 2019 data set (multi-class semantic segmentation with 300 CT scans) resulted into a powerful predictor based on the standard 3D U-Net model. With this experiment, we could show that the MIScnn framework enables researchers to rapidly set up a complete medical image segmentation pipeline by using just a few lines of code. The source code for MIScnn is available in the Git repository: https://github.com/frankkramer-lab/MIScnn.