Researcher profile

John E. Sader

John E. Sader contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - Baseline
4works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2026arXiv

Settling of chiral particles in a turbulent flow

Chiral particles are experimentally investigated while settling inwater with various turbulence intensity levels. The locations and orientations of the particles are tracked over time, allowing the close investigation of the particles' settling dynamics. The generated turbulent flow is measured using laser Doppler anemometry (LDA), and the turbulence strength varies between experiments in the range $0 \leq Re_λ\leq 250$. Starting with quiescent particle settling, the chiral particle's orientation dynamics are studied, revealing a preferred alignment and a strong translation-rotation coupling. The particle chirality determines the preferred rotation direction, though the alignment and translation-rotation coupling gradually vanish with increasing turbulence. We identify multiple settling modes for the chiral particles, which are characterised by the evolution of the rotation angles. Finally, a theoretical model assuming a simplified chiral particle in Stokes flow clarifies the emergence of each settling mode.

preprint2016arXiv

A virtual instrument to standardise the calibration of atomic force microscope cantilevers

Atomic force microscope (AFM) users often calibrate the spring constants of cantilevers using functionality built into individual instruments. This is performed without reference to a global standard, which hinders robust comparison of force measurements reported by different laboratories. In this article, we describe a virtual instrument (an internet-based initiative) whereby users from all laboratories can instantly and quantitatively compare their calibration measurements to those of others - standardising AFM force measurements - and simultaneously enabling non-invasive calibration of AFM cantilevers of any geometry. This global calibration initiative requires no additional instrumentation or data processing on the part of the user. It utilises a single website where users upload currently available data. A proof-of-principle demonstration of this initiative is presented using measured data from five independent laboratories across three countries, which also allows for an assessment of current calibration.

preprint2015arXiv

Photo-induced electron transfer in the strong coupling regime: Waveguide-plasmon polaritons

Reversible exchange of photons between a material and an optical cavity can lead to the formation of hybrid light--matter states where material properties such as the work function\cite{Hutchison_AM2013a}, chemical reactivity\cite{Hutchison_ACIE2012a}, ultra--fast energy relaxation \cite{Salomon_ACIE2009a,Gomez_TJOPCB2012a} and electrical conductivity\cite{Orgiu_NM2015a} of matter differ significantly to those of the same material in the absence of strong interactions with the electromagnetic fields. Here we show that strong light--matter coupling between confined photons on a semiconductor waveguide and localised plasmon resonances on metal nanowires modifies the efficiency of the photo--induced charge--transfer rate of plasmonic derived (hot) electrons into accepting states in the semiconductor material. Ultra--fast spectroscopy measurements reveal a strong correlation between the amplitude of the transient signals, attributed to electrons residing in the semiconductor, and the hybridization of waveguide and plasmon excitations.

preprint2012arXiv

Stress-Induced Variations in the Stiffness of Micro- and Nanocantilever Beams

The effect of surface stress on the stiffness of cantilever beams remains an outstanding problem in the physical sciences. While numerous experimental studies report significant stiffness change due to surface stress, theoretical predictions are unable to rigorously and quantitatively reconcile these observations. In this Letter, we present the first controlled measurements of stress-induced change in cantilever stiffness with commensurate theoretical quantification. Simultaneous measurements are also performed on equivalent clamped-clamped beams. All experimental results are quantitatively and accurately predicted using elasticity theory. We also present conclusive experimental evidence for invalidity of the longstanding and unphysical axial force model, which has been widely applied to interpret measurements using cantilever beams. Our findings will be of value in the development of micro- and nanoscale resonant mechanical sensors.