Source author record

Joël Chevrier

Joël Chevrier appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2014arXiv

Transmission and reflection characteristics of metal-coated optical fiber tip pairs

The optical transmission and reflection in between two metalized optical fiber tips is studied in the optical near-field and far-field domains. Besides aluminum-coated tips for near-field scanning optical microscopy (NSOM), specifically developed gold-coated fiber tips cut by focused ion beam (FIB) are investigated. Transverse transmission maps of sub-wavelength width clearly evidence optical near-field coupling between the tips for short tip distances and becomes essentially Gaussian-shaped for larger distances in the far-field regime. Moreover concentric reflection fringes observed for NSOM-type tips illustrate the influence of the receiving fiber tip on the emission pattern of the source tip.

preprint2014arXiv

Variable frequency characterization of interaction at nanoscale in linear dynamic AFM: an FFM primer

Using electrostatic coupling between an AFM tip and a metallic surface as a test interaction, we here present the measurement of the force between the tip and the surface, together with the measurement of the interaction stiffness and the associated dissipation. These three quantities constitute a full characterization of the interaction at nanoscale. They are measured independently, simultaneously and quantitatively at the same place. This is made possible thanks to a force feedback method that ensures the DC immobility of the tip and to the simultaneous application of a sub-nanometer oscillation to the tip. In this established linear regime, stiffness and damping are directly obtained from amplitude and phase change measurements. The needed information for this linear transformation is solely the lever properties in the experimental context. Knowledge of k, its stiffness, its damping coefficient and Q0, its first resonance frequency is shown to be sufficient in the frequency range we are here exploring. Finally, we demonstrate that this method is not restricted to the lever resonance frequency. To the contrary, this interaction characterization whose resolution is limited by the Brownian motion, can be used at any frequencies with essentially the same performances. We believe that simultaneous and independent measurements of force, stiffness and damping, out of lever resonance, at nanoscale, and within the context of linear response define a new AFM paradigm that we call Force Feedback Microscopy (FFM). This article details the use of FFM using a well known and easy to implement electrostatic interaction between a regular AFM tip and a metallic surface in air.

preprint2013arXiv

Spectroscopic investigation of local mechanical impedance of living cells

The mechanical properties of PC12 living cells have been studied at the nanoscale with a Force Feedback Microscope using two experimental approaches. Firstly, the local mechanical impedance of the cell membrane has been mapped simultaneously to the cell morphology at constant force. As the force of the interaction is gradually increased, we observed the appearance of the sub-membrane cytoskeleton. We shall compare the results obtained with this method with the measurement of other existing techniques. Secondly, a spectroscopic investigation has been performed varying the indentation of the tip in the cell membrane and consequently the force applied on it. In contrast with conventional dynamic atomic force microscopy techniques, here the small oscillation amplitude of the tip is not necessarily imposed at the cantilever first eigenmode. This allows the user to arbitrarily choose the excitation frequency in developing spectroscopic AFM techniques. The mechanical response of the PC12 cell membrane is found to be frequency dependent in the 1 kHz - 10 kHz range. The damping coefficient is reproducibly observed to decrease when the excitation frequency is increased.

preprint2011arXiv

A fibered interference scanning optical microscope for living cell imaging

We report on the 3-dimensional imaging of biological cells including living neurons by a recently developed fibered interferometric Scanning Optical Microscope. The topography and surface structure of mouse fibroblasts and hippocampal neurons are clearly revealed. This straightforward technique allows fast, high resolution observation of samples in liquids without lengthy alignment procedures or costly components.