Researcher profile

Jinshan Tang

Jinshan Tang contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2020arXiv

A Deep Learning-Based Method for Automatic Segmentation of Proximal Femur from Quantitative Computed Tomography Images

Purpose: Proximal femur image analyses based on quantitative computed tomography (QCT) provide a method to quantify the bone density and evaluate osteoporosis and risk of fracture. We aim to develop a deep-learning-based method for automatic proximal femur segmentation. Methods and Materials: We developed a 3D image segmentation method based on V-Net, an end-to-end fully convolutional neural network (CNN), to extract the proximal femur QCT images automatically. The proposed V-net methodology adopts a compound loss function, which includes a Dice loss and a L2 regularizer. We performed experiments to evaluate the effectiveness of the proposed segmentation method. In the experiments, a QCT dataset which included 397 QCT subjects was used. For the QCT image of each subject, the ground truth for the proximal femur was delineated by a well-trained scientist. During the experiments for the entire cohort then for male and female subjects separately, 90% of the subjects were used in 10-fold cross-validation for training and internal validation, and to select the optimal parameters of the proposed models; the rest of the subjects were used to evaluate the performance of models. Results: Visual comparison demonstrated high agreement between the model prediction and ground truth contours of the proximal femur portion of the QCT images. In the entire cohort, the proposed model achieved a Dice score of 0.9815, a sensitivity of 0.9852 and a specificity of 0.9992. In addition, an R2 score of 0.9956 (p<0.001) was obtained when comparing the volumes measured by our model prediction with the ground truth. Conclusion: This method shows a great promise for clinical application to QCT and QCT-based finite element analysis of the proximal femur for evaluating osteoporosis and hip fracture risk.

preprint2020arXiv

A Novel Method for ECG Signal Classification via One-Dimensional Convolutional Neural Network

This paper presents an end-to-end ECG signal classification method based on a novel segmentation strategy via 1D Convolutional Neural Networks (CNN) to aid the classification of ECG signals. The ECG segmentation strategy named R-R-R strategy (i.e., retaining ECG data between the R peaks just before and after the current R peak) for segmenting the original ECG data into segments in order to train and test the 1D CNN models. The novel strategy mimics physicians in scanning ECG to a greater extent, and maximizes the inherent information of ECG segments. The performance of the classification models for 5-class and 6-class are verified with ECG signals from 48 records of the MIT-BIH arrhythmia database. As the heartbeat types are divided into 5 classes (i.e., normal beat, left bundle branch block beat, right bundle branch block beat, ventricular ectopic beat, and paced beat) in the MIT-BIH, the best classification accuracy, the area under the curve (AUC), the sensitivity and the F1-score reach 99.24%, 0.9994, 0.99 and 0.99, respectively. As the heartbeat types are divided into 6 classes (i.e., normal beat, left bundle branch block beat, right bundle branch block beat, ventricular ectopic beat, paced beat and other beats) in the MIT-BIH, the beat classification accuracy, the AUC, the sensitivity, and the F1-score reach 97.02%, 0.9966, 0.97, and 0.97, respectively. Meanwhile, according to the recommended practice from the Association for Advancement of Medical Instrumentation (AAMI), the heartbeat types are divided into 5 classes (i.e., normal beat, supraventricular ectopic beats, ventricular ectopic beats, fusion beats, and unclassifiable beats), the beat classification accuracy, the sensitivity, and the F1-score reach 97.45%, 0.97, and 0.97, respectively. The experimental results show that the proposed method achieves better performance than the state-of-the-art methods.