Source author record

Jiangfeng Hu

Jiangfeng Hu appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2020arXiv

Active suppression of temperature oscillation from a pulse-tube cryocooler in a cryogen-free cryostat: Part 1. Simulation modeling from thermal response characteristics

A cryogen-free cryostat cooled using a 4 K commercial GM or pulse tube cryocooler (PTC) displays temperature oscillations caused by the intrinsic working principle of the regenerative cryocooler. To dampen such oscillations usually requires either a large heat capacity or a large thermal resistance. To understand this phenomenon better and suppress it more effectively, both the step response characteristic and the intrinsic oscillation characteristic of cryostat have been used to obtain the complete transfer functions of a simulation model. The latter is used to test and optimize traditional PID feedback control. The results showed this approach has almost no effect on the temperature oscillation amplitude. Based on this simulation model, a novel active method was proposed and tested numerically. Simulation results predict the method should suppress the amplitude of the original temperature oscillation by a factor of two.

preprint2020arXiv

Active suppression of temperature oscillation from a pulse-tube cryocooler in a cryogen-free cryostat: Part 2. Experimental realization

A cryogen-free cryostat cooled by a closed cycle cryocooler is compact, can provide uninterrupted long-term operation (up to ten thousand hours) and is suited to temperatures from 3 K to 300 K. Its intrinsic temperature oscillation, however, limits its application in experiments requiring high thermal stability at low temperature (below 77 K). Passive suppression methods are effective but all suffer from drawbacks. We describe a novel, active suppression scheme more efficient than traditional proportional-integral (PI) control. The experimental results show that it can reduce the standard deviation of the temperature oscillation by a further 30% compared with PI feedback. To the best of our knowledge, this is the first time such active suppression of temperature oscillations has been implemented with the cryogen-free cryostat. The results also show, however, that an unwanted lower frequency thermal noise will be generated, which appears to be the limit of the method. Nevertheless, the approach could be used to improve the temperature stability in all cryogen-free cryostats.

preprint2020arXiv

Prediction and realization of a temperature control limit at low temperatures in SPRIGT

On May 20th 2019, the World Metrology Day, the Bureau International des Poids et Mesures announced a major revision to the four more SI units. The base unit, the kelvin, is defined by fixing the value of Boltzmann constant as indicated in Mise en pratique for the definition of the kelvin in the SI. To realize the new kelvin, a novel practical realization technique of single-pressure refractive-index gas thermometry (SPRIGT) has been jointly developed by the TIPC-CAS in China and the LNE-Cnam in France. To carry out accurate SPRIGT, experimental methods have been implemented and micro-kelvin level temperature control limits have been predicted and achieved at 5 K to 26 K. The resonator temperature stability can be maintained to within better than 8 μK of its set point with an integration time 33.6 s over 180 h. Besides, solutions for further improving the stability were also demonstrated, which can be a reference for temperature metrology field worldwide and other fields where high-stability temperature is required. The present work should also provide a solid foundation for international data comparison of thermodynamic temperature at low temperatures, and will promote realizations of the new kelvin and the spread of high-accuracy, low-temperature metrology.