Source author record

Jian-Feng Liu

Jian-Feng Liu appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Magnetar Engines in Fast Blue Optical Transients and Their Connections with SLSNe, SNe Ic-BL, and lGRBs

We fit the multi-band lightcurves of 40 fast blue optical transients (FBOTs) with the magnetar engine model. The mass of the FBOT ejecta, the initial spin period and polar magnetic field of the FBOT magnetars are respectively constrained to $M_{\rm{ej}}=0.18^{+0.52}_{-0.13}\,M_\odot$, $P_{\rm{i}}=9.4^{+8.1}_{-3.9}\,{\rm{ms}}$, and $B_{\rm p}=7^{+16}_{-5}\times10^{14}\,{\rm{G}}$. The wide distribution of the value of $B_{\rm p}$ spreads the parameter ranges of the magnetars from superluminous supernovae (SLSNe) to broad-line Type Ic supernovae (SNe Ic-BL; some are observed to be associated with long-duration gamma-ray bursts), which are also suggested to be driven by magnetars. Combining FBOTs with the other transients, we find a strong universal anti-correlation as $P_{\rm{i}}\propto{M_{\rm{ej}}^{-0.45}}$, indicating them could share a common origin. To be specific, it is suspected that all of these transients originate from collapse of extreme-stripped stars in close binary systems, but with different progenitor masses. As a result, FBOTs distinct themselves by their small ejecta masses with an upper limit of ${\sim}1\,M_\odot$, which leads to an observational separation in the rise time of the lightcurves $\sim12\,{\rm d}$. In addition, the FBOTs together with SLSNe can be separated from SNe Ic-BL by an empirical line in the $M_{\rm peak}-t_{\rm rise}$ plane corresponding to an energy requirement of a mass of $^{56}$Ni of $\sim0.3M_{\rm ej}$, where $M_{\rm peak}$ is the peak absolute magnitude of the transients and $t_{\rm rise}$ is the rise time.

preprint2016arXiv

Design and simulation of a 12-bit, 40 MSPS asynchronous SAR ADC for the readout of PMT signal

High precision and large dynamic range measurement are required in the readout systems for the Water Cherenkov Detector Array (WCDA) in Large High Altitude Air Shower Observatory (LHAASO). This paper presents a prototype of 12-bit 40 MSPS Analog-to-Digital Converter (ADC) Application Specific Integrated Circuit (ASIC) designed for the readout of LHAASO WCDA. Combining this ADC and the front-end ASIC finished in our previous work, high precision charge measurement can be achieved based on the digital peak detection method. This ADC is implemented based on power-efficient Successive Approximation Register (SAR) architecture, which incorporates the key parts such as Capacitive Digital-to-Analog Converter (CDAC), dynamic comparator and asynchronous SAR control logic. The simulation results indicate that the Effective Number Of Bits (ENOB) with a sampling rate of 40 MSPS is better than 10 bits in an input frequency range below 20 MHz, while its core power consumption is 6.6 mW per channel. The above results are good enough for the readout requirements of the WCDA.

preprint2015arXiv

The Analog Front-end Prototype Electronics Designed for LHAASO WCDA

In the readout electronics of the Water Cerenkov Detector Array (WCDA) in the Large High Altitude Air Shower Observatory (LHAASO) experiment, both high-resolution charge and time measurement are required over a dynamic range from 1 photoelectron (P.E.) to 4000 P.E. The Analog Front-end (AFE) circuit is one of the crucial parts in the whole readout electronics. We designed and optimized a prototype of the AFE through parameter calculation and circuit simulation, and conducted initial electronics tests on this prototype to evaluate its performance. Test results indicate that the charge resolution is better than 1% @ 4000 P.E. and remains better than 10% @ 1 P.E., and the time resolution is better than 0.5 ns RMS, which is better than application requirement.