Source author record

Jens Viefhaus

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

2works
6topics
4close collaborators

Published work

2 publications

preprint2023arXiv

Artificial intelligence for online characterization of ultrashort X-ray free-electron laser pulses

X-ray free-electron lasers (XFELs) as the world's brightest light sources provide ultrashort X-ray pulses with a duration typically in the order of femtoseconds. Recently, they have approached and entered the attosecond regime, which holds new promises for single-molecule imaging and studying nonlinear and ultrafast phenomena such as localized electron dynamics. The technological evolution of XFELs toward well-controllable light sources for precise metrology of ultrafast processes has been, however, hampered by the diagnostic capabilities for characterizing X-ray pulses at the attosecond frontier. In this regard, the spectroscopic technique of photoelectron angular streaking has successfully proven how to non-destructively retrieve the exact time-energy structure of XFEL pulses on a single-shot basis. By using artificial intelligence techniques, in particular convolutional neural networks, we here show how this technique can be leveraged from its proof-of-principle stage toward routine diagnostics even at high-repetition-rate XFELs, thus enhancing and refining their scientific accessibility in all related disciplines.

preprint2015arXiv

Water Window Ptychographic Imaging with Characterized Coherent X-rays

We report on a ptychographical coherent diffractive imaging experiment in the water window with focused soft X-rays at 500 eV500~\mathrm{eV}. An X-ray beam with high degree of coherence was selected for ptychography at the P04 beamline of the PETRA III synchrotron radiation source. We measured the beam coherence with the newly developed non-redundant array method. A pinhole 2.6 μm2.6~\mathrm{μm} in size selected the coherent part of the beam and was used for ptychographic measurements of a lithographically manufactured test sample and fossil diatom. The achieved resolution was 53 nm53~\mathrm{nm} for the test sample and only limited by the size of the detector. The diatom was imaged at a resolution better than 90 nm90~\mathrm{nm}.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.