Source author record

Janet M. Conrad

Janet M. Conrad appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

9works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2026arXiv

The $ν$ EYE Neutrino Telescope: Conceptual Design Report

The {$\bfνEYE$} (``new eye'', Neutrino Experiment at YEmilab, \href{https://sites.google.com/korea.ac.kr/the-nueye-telescope} {\tt nuEYE.korea.ac.kr}) neutrino project leverages the existing large pit at Yemilab located in South Korea, to reveal the existence of sterile neutrino, the up-turn of the neutrinos from the Sun, and the first minimum of the neutrino oscillation over distances on the order of tens of kilometers for the first time. This initiative is expected to facilitate a wide range of significant scientific and technological advancements within both South Korean and international communities engaged in neutrino science and technology. The {$\bfνEYE$} aims to investigate the largely unexplored sector of almost-massless lepton in the elementary particle physics in detail. The emphasis will be placed on the study of real time nuclear processes and reactions involving possible sterile neutrinos on timescales down to nanoseconds in ultra-high intense or radioactive neutrino beams for the first time in the world; the {$\bfνEYE$} looks at to-be universal oscillation (``up-turn'' in the electron neutrino survival probability) of neutrinos predicted by the three neutrino oscillation paradigm. This will confirm or deny our current understanding on the particle interactions of the lepton sector; and measurement of the first oscillation minimum between the first and second neutrinos in mass.

preprint2022arXiv

Cascade Appearance Signatures of Sterile Neutrinos at 1-100 TeV

Neutrino telescopes provide strong sensitivity to sterile neutrino oscillations through matter-enhanced oscillation, occurring in the few TeV energy range for eV$^{2}$-scale neutrino mass-squared splittings. Prior searches have focused on $ν_μ$ disappearance, which has a particularly strong sensitivity to the mixing angle $θ_{24}$ via $ν_μ\rightarrowν_s$ transitions. Nowadays, the $ν_μ\rightarrowν_e$ and $ν_μ\rightarrowν_τ$ appearance channels have been considered less promising at neutrino telescopes, due in part to the much smaller target volume for cascades relative to tracks. This work explores the detectability of these signatures at neutrino telescopes given present constraints on sterile neutrino mixing, and as an example, forecasts the sensitivity of the IceCube Neutrino Observatory to the mixing angles $θ_{14}$, $θ_{24}$, and $θ_{34}$ in the 3+1 sterile neutrino model using the cascade channel with ten years of data. We find that $ν_τ$ appearance signatures consistent with the existing IceCube $ν_μ$ disappearance best-fit point are discoverable for values of $θ_{34}$ consistent with world constraints, and that the sterile neutrino parameters favored by the BEST and gallium anomalies are expected to be testable at the 95\% confidence level.

preprint2022arXiv

Convolutional Neural Networks for Shower Energy Prediction in Liquid Argon Time Projection Chambers

When electrons with energies of $O(100)$ MeV pass through a liquid argon time projection chamber (LArTPC), they deposit energy in the form of electromagnetic showers. Methods to reconstruct the energy of these showers in LArTPCs often rely on the combination of a clustering algorithm and a linear calibration between the shower energy and charge contained in the cluster. This reconstruction process could be improved through the use of a convolutional neural network (CNN). Here we discuss the performance of various CNN-based models on simulated LArTPC images, and then compare the best performing models to a typical linear calibration algorithm. We show that the CNN method is able to address inefficiencies caused by unresponsive wires in LArTPCs and reconstruct a larger fraction of imperfect events to within 5% accuracy compared with the linear algorithm.

preprint2021arXiv

High current $\mathrm{H}_2^+$ beams from a filament-driven multicusp ion source

Recently, the use of $\mathrm{H}_2^+$ ions instead of protons to overcome space charge challenges in compact cyclotrons has received much attention. This technique has the potential to increase the available beam current from compact cyclotrons by an order of magnitude, paving the way for applications in energy research, medical isotope production, and particle physics, e.g. a decisive search for sterile neutrinos through the IsoDAR experiment. For IsoDAR we go a step beyond just using $\mathrm{H}_2^+$ and add pre-bunching through a Radio-Frequency Quadrupole (RFQ) embedded in the cyclotron yoke. This puts beam purity and beam quality constraints on the ion source that no published ion source has simultaneously demonstrated so far. Here, we report results from a new multicusp ion source (MIST-1) that produces the world's highest steady-state current of $\mathrm{H}_2^+$ from this type of ion source (1 mA), with exceptionally low emittance (0.05 $π$-mm-mrad, RMS, normalized) and high purity (80% $\mathrm{H}_2^+$). This result shows the feasibility of using a multicusp ion source for IsoDAR and the RFQ direct injection prototype, and paves the way to record breaking continuous wave (cw) beam currents of 5 mA $\mathrm{H}_2^+$ (equivalent to 10 mA protons) from compact cyclotrons, ideal for underground installation. This represents a significant advance, with impact on neutrino physics specifically and high power cyclotron design in general.

preprint2021arXiv

Order-of-Magnitude Beam Current Improvement in Compact Cyclotrons

There is great need for high intensity proton beams from compact particle accelerators in particle physics, medical isotope production, and materials- and energy-research. To address this need, we present, for the first time, a design for a compact isochronous cyclotron that will be able to deliver 10 mA of 60 MeV protons - an order of magnitude higher than on-market compact cyclotrons and a factor four higher than research machines. A key breakthrough is that vortex motion is incorporated in the design of a cyclotron, leading to clean extraction. Beam losses on the septa of the electrostatic extraction channels stay below 50 W (a factor four below the required safety limit), while maintaining good beam quality. We present a set of highly accurate particle-in-cell simulations, and an uncertainty quantification of select beam input parameters using machine learning, showing the robustness of the design. This design can be utilized for beams for experiments in particle and nuclear physics, materials science and medical physics as well as for industrial applications.

preprint2015arXiv

KPipe: a decisive test for muon neutrino disappearance

The short baseline neutrino oscillation experiment, KPipe, is designed to perform a sensitive search for muon neutrino disappearance in the current global fit allowed regions for sterile neutrinos. KPipe is to be located at the Material Life Science Experimental Facility at J-PARC: the world's most intense source of 236~MeV, monoenergetic muon neutrinos. By measuring the $ν_μ$ charged current interaction rate along a 120~m long, 3~m diameter detector, KPipe can map out short baseline oscillations over an L/E of 0.14 to 0.64~m/MeV. Using a long, single detector to measure the $ν_μ$ interaction rate as a function of distance largely eliminates the systematic uncertainties associated with cross sections and fluxes. In this paper, we show that KPipe can cover the current global best fit to 5$σ$ after 3 years of running.

preprint2015arXiv

The IsoDAR High Intensity H$_2^+$ Transport and Injection Tests

This technical report reviews the tests performed at the Best Cyclotron Systems, Inc. facility in regards to developing a cost effective ion source, beam line transport system, and acceleration system capable of high H$_2^+$ current output for the IsoDAR (Isotope Decay At Rest) experiment. We begin by outlining the requirements for the IsoDAR experiment then provide overview of the Versatile Ion Source, Low Energy Beam Transport system, spiral inflector, and cyclotron. The experimental measurements are then discussed and the results are compared with a thorough set of simulation studies. Of particular importance we note that the Versatile Ion Source (VIS) proved to be a reliable ion source capable of generating a large amount of H$_2^+$ current. The results suggest that with further upgrades, the VIS could potentially be a suitable candidate for IsoDAR. The conclusion outlines the key results from our tests and introduces the forthcoming work this technical report has motivated.

preprint2013arXiv

The LSND and MiniBooNE Oscillation Searches at High $Δm^2$

This paper reviews the results of the LSND and MiniBooNE experiments. The primary goal of each experiment was to effect sensitive searches for neutrino oscillations in the mass region with $Δm^2 \sim 1$ eV$^2$. The two experiments are complementary, and so the comparison of results can bring additional information with respect to models with sterile neutrinos. Both experiments obtained evidence for $\bar ν_μ\rightarrow \bar ν_e$ oscillations, and MiniBooNE also observed a $ν_μ\rightarrow ν_e$ excess. In this paper, we review the design, analysis, and results from these experiments. We then consider the results within the global context of sterile neutrino oscillation models. The final data sets require a more extended model than the simple single sterile neutrino model imagined at the time that LSND drew to a close and MiniBooNE began. We show that there are apparent incompatibilities between data sets in models with two sterile neutrinos. However, these incompatibilities may be explained with variations within the systematic error. Overall, models with two (or three) sterile neutrinos seem to succeed in fitting the global data, and they make interesting predictions for future experiments.