Researcher profile

Jan C. Petersen

Jan C. Petersen contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - Baseline
5works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2020arXiv

Continuous-wave coherent Raman spectroscopy for improving the accuracy of Raman shifts

Raman spectroscopy is an appealing technique that probes molecular vibrations in a wide variety of materials with virtually no sample preparation. However, accurate and reliable Raman measurements are still a challenge and require more robust and practical calibration methods. We demonstrate the implementation of a simple low-cost continuous-wave stimulated Raman spectroscopy scheme for accurate and high-resolution spectroscopy. We perform shot noise limited continuous-wave stimulated Raman scattering (cwSRS) as well as continuous-wave coherent anti-Stokes Raman scattering (cwCARS) on polystyrene samples. Our method enables accurate determination of Raman shifts with an uncertainty below 0.1 cm$^{-1}$. The setup is used for the characterization of reference materials required for the calibration of Raman spectrometers. Compared with existing standards, we provide an order of magnitude improvement of the uncertainty of Raman energy shifts in a polystyrene reference material.

preprint2016arXiv

Off-axis QEPAS using a pulsed nanosecond Mid-Infrared Optical Parametric Oscillator

A trace gas sensor, based on quartz-enhanced photoacoustic spectroscopy (QEPAS), consisting of two acoustically coupled micro-resonators (mR) with an off-axis 20 kHz quartz tuning fork (QTF) is demonstrated. The complete acoustically coupled mR system is optimized based on finite element simulations and experimentally verified. The QEPAS sensor is pumped resonantly by a nanosecond pulsed single-mode mid-infrared optical parametric oscillator (MIR OPO). The sensor is used for spectroscopic measurements on methane in the 3.1 um to 3.5 um wavelength region with a resolution bandwidth of 1 cm^-1 and a detection limit of 0.8 ppm. An Allan deviation analysis shows that the detection limit at optimum integration time for the QEPAS sensor is 32 ppbv@190s and that the background noise is solely due to the thermal noise of the QTF.

preprint2015arXiv

Differential high-resolution stimulated CW Raman spectroscopy of hydrogen in a hollow-core fiber

We demonstrate sensitive high-resolution stimulated Raman measurements of hydrogen using a hollow-core photonic crystal fiber (HC-PCF). The Raman transition is pumped by a narrow linewidth (<50 kHz) 1064 nm continuous-wave (CW) fiber laser. The probe light is produced by a homebuilt CW optical parametric oscillator (OPO), tunable from around 800 nm to 1300 nm (linewidth ~ 5 MHz). These narrow linewidth lasers allow for an excellent spectral resolution of approximately 10^-4 cm^(-1). The setup employs a differential measurement technique for noise rejection in the probe beam, which also eliminates background signals from the fiber. With the high sensitivity obtained, Raman signals were observed with only a few mW of optical power in both the pump and probe beams. This demonstration allows for high resolution Raman identification of molecules and quantification of Raman signal strengths.

preprint2014arXiv

A versatile integrating sphere based photoacoustic sensor for trace gas monitoring

A compact versatile photoacoustic (PA) sensor for trace gas detection is reported. The sensor is based on an integrating sphere as the PA absorption cell with an organ pipe tube attached to increase the sensitivity of the PA sensor. The versatility and enhancement of the sensitivity of the PA signal is investigated by monitoring specific ro-vibrational lines of CO2 in the 2 mm wavelength region and of NO2 in the 405 nm region. The measured enhancement factor of the PA signal exceeds 1200, which is due to the acoustic resonance of the tube and the absorption enhancement of the integrating sphere relatively to a non-resonant single pass cell. It is observed that the background absorption signals are highly attenuated due to the thermal conduction and diffusion effects in the polytetrafluoroethylene cell walls. This demonstrates that careful choice of cell wall materials can be highly beneficial to the sensitivity of the PA sensor. These properties makes the sensor suitable for various practical sensor applications in the ultraviolet to the near infrared wavelength region, including climate, environmental and industrial monitoring.

preprint2014arXiv

Phase-Sensitive Noise Suppression in a Photoacoustic Sensor based on Acoustic Circular Membrane Modes

A photoacoustic (PA) sensor based on higher order acoustic modes is demonstrated. The PA sensor is designed to enhance the gas-detection performance and simultaneously suppress ambient noise sources (e.g. flow noise, electrical noise and external acoustic noise). Two microphones are used and positioned such that the PA signals are ($π$) out of phase. Ambient acoustic noise are approximately in the same phase and will be subtracted and thus improve the SNR. In addition, by placing the gas in- and outlets so that the gas flows through the node of the first higher order membrane mode the coupling of flow noise is approximately 20 dB lower compared with flow through the fundamental mode at 5 L/min. The noise reduction and thus the increase in sensitivity is demonstrated by measuring vibrational lines of methanol and methane using a broadband interband cascade laser emitting radiation at 3.38 $μ$m. A signal-to-noise improvement of 20 (26 dB) using higher order modes are demonstrated compared with the fundamental mode. The maximum normalized noise equivalent absorption coefficient is 1.1 $\times 10^{-6}$ W cm$^{-1}$ Hz$^{1/2}$ for a flow of 5 L/min. It is anticipated that the noise cancelation strategy may find use in many practical industrial and environmental PA sensors, where ambient noise sources plays a crucial role for the absolute sensitive.