Researcher profile

J. R. Crespo López-Urrutia

J. R. Crespo López-Urrutia contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
12works
0followers
10topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

12 published item(s)

preprint2022arXiv

New Horizons: Scalar and Vector Ultralight Dark Matter

The last decade has seen unprecedented effort in dark matter model building at all mass scales coupled with the design of numerous new detection strategies. Transformative advances in quantum technologies have led to a plethora of new high-precision quantum sensors and dark matter detection strategies for ultralight ($<10\,$eV) bosonic dark matter that can be described by an oscillating classical, largely coherent field. This white paper focuses on searches for wavelike scalar and vector dark matter candidates.

preprint2020arXiv

High-Precision Determination of Oxygen-K$α$ Transition Energy Excludes Incongruent Motion of Interstellar Oxygen

We demonstrate a widely applicable technique to absolutely calibrate the energy scale of x-ray spectra with experimentally well-known and accurately calculable transitions of highly charged ions, allowing us to measure the K-shell Rydberg spectrum of molecular O$_2$ with 8 meV uncertainty. We reveal a systematic $\sim$450 meV shift from previous literature values, and settle an extraordinary discrepancy between astrophysical and laboratory measurements of neutral atomic oxygen, the latter being calibrated against the aforementioned O$_2$ literature values. Because of the widespread use of such, now deprecated, references, our method impacts on many branches of x-ray absorption spectroscopy. Moreover, it potentially reduces absolute uncertainties there to below the meV level.

preprint2020arXiv

XUV frequency comb operation in an astigmatism-compensated enhancement cavity

We have developed an extreme ultraviolet (XUV) frequency comb for performing ultra-high precision spectroscopy on the many XUV transitions found in highly charged ions (HCI). Femtosecond pulses from a 100 MHz phase-stabilized near-infrared frequency comb are amplified and then fed into a femtosecond enhancement cavity (fsEC) inside an ultra-high vacuum chamber. The low-dispersion fsEC coherently superposes several hundred incident pulses and, with a single cylindrical optical element, fully compensates astigmatism at the $w_0=15μ$m waist cavity focus. With a gas jet installed there, intensities reaching $\sim10^{14}$ W/cm$^2$ generate coherent high harmonics with a comb spectrum at 100 MHz rate. We couple out of the fsEC harmonics from the 7th up to the 35th (42 eV; 30 nm) to be used in upcoming experiments on HCI frequency metrology.

preprint2014arXiv

Low-Background In-Trap Decay Spectroscopy with TITAN at TRIUMF

An in-trap decay spectroscopy setup has been developed and constructed for use with the TITAN facility at TRIUMF. The goal of this device is to observe weak electron-capture (EC) branching ratios for the odd-odd intermediate nuclei in the $ββ$ decay process. This apparatus consists of an up-to 6 Tesla, open-access spectroscopy ion-trap, surrounded radially by up to 7 planar Si(Li) detectors which are separated from the trap by thin Be windows. This configuration provides a significant increase in sensitivity for the detection of low-energy photons by providing backing-free ion storage and eliminating charged-particle-induced backgrounds. An intense electron beam is also employed to increase the charge-states of the trapped ions, thus providing storage times on the order of minutes, allowing for decay-spectroscopy measurements. The technique of multiple ion-bunch stacking was also recently demonstrated, which further extends the measurement possibilities of this apparatus. The current status of the facility and initial results from a $^{116}$In measurement are presented.

preprint2014arXiv

The TITAN in-trap decay spectroscopy facility at TRIUMF

This article presents an upgraded in-trap decay spectroscopy apparatus which has been developed and constructed for use with TRIUMF&#39;s Ion Trap for Atomic and Nuclear science (TITAN). This device consists of an open-access electron-beam ion-trap (EBIT), which is surrounded radially by seven low-energy planar Si(Li) detectors. The environment of the EBIT allows for the detection of low-energy photons by providing backing-free storage of the radioactive ions, while guiding charged decay particles away from the trap centre via the strong (up to 6 T) magnetic field. In addition to excellent ion confinement and storage, the EBIT also provides a venue for performing decay spectroscopy on highly-charged radioactive ions. Recent technical advancements have been able to provide a significant increase in sensitivity for low-energy photon detection, towards the goal of measuring weak electron-capture branching ratios of the intermediate nuclei in the two-neutrino double beta ($2νββ$) decay process. The design, development, and commissioning of this apparatus are presented together with the main physics objectives. The future of the device and experimental technique are discussed.

preprint2013arXiv

Decay rate measurement of the first vibrationally excited state of MgH$^+$ in a cryogenic Paul trap

We present a method to measure the decay rate of the first excited vibrational state of simple polar molecular ions being part of a Coulomb crystal in a cryogenic linear Paul trap. Specifically, we have monitored the decay of the $|ν$=$1,J$=$1 \rangle_X$ towards the $|ν$=$0,J$=$0 \rangle_X$ level in MgH$^+$ by saturated laser excitation of the $|ν$=$0,J$=$2 \rangle_X$-$|ν$=$1,J$=$1 \rangle_X$ transition followed by state selective resonance enhanced two-photon dissociation out of the $|ν$=$0,J$=$2 \rangle_X$ level. The technique enables the determination of decay rates, and thus absorption strengths, with an accuracy at the few percent level.

preprint2013arXiv

Major role of multielectronic K-L inter-shell resonant recombination processes in Li- to O-like ions of Ar, Fe, and Kr

Dielectronic and higher-order resonant electron recombination processes including a K-shell excitation were systematically measured at high resolution in electron beam ion traps. Storing highly charged Ar, Fe, and Kr ions, the dependence on atomic number Z of the contribution of these processes to the total recombination cross section was studied and compared with theoretical calculations. Large higher-order resonant recombination contributions are found, especially for systems with 10<Z<36. In some cases, they even surpass the strength of the dielectronic channel, which was hitherto presumed to be always the dominant one. These findings have consequences for the modeling of high-temperatur plasmas. Features attributed to inter-shell quadruelectronic recombination were also observed. The experimental data obtained for the He-like to O-like isoelectronic sequences compare well with the results of advanced relativistic distorted-wave calculations employing multiconfiguration Dirac-Fock bound state wave functions that include threefold and fourfold excitations.

preprint2013arXiv

X-ray resonant photoexcitation: line widths and energies of Kα transitions in highly charged Fe ions

Photoabsorption by and fluorescence of the Kα transitions in highly charged iron ions are essential mechanisms for X-ray radiation transfer in astrophysical environments. We study photoabsorption due to the main Kα transitions in highly charged iron ions from heliumlike to fluorinelike (Fe 24+...17+) using monochromatic X-rays around 6.6 keV at the PETRA III synchrotron photon source. Natural linewidths were determined with hitherto unattained accuracy. The observed transitions are of particular interest for the understanding of photoexcited plasmas found in X-ray binaries and active galactic nuclei.

preprint2011arXiv

First Use of High Charge States for Mass Measurements of Short-lived Nuclides in a Penning Trap

Penning trap mass measurements of short-lived nuclides have been performed for the first time with highly-charged ions (HCI), using the TITAN facility at TRIUMF. Compared to singly-charged ions, this provides an improvement in experimental precision that scales with the charge state q. Neutron-deficient Rb-isotopes have been charge bred in an electron beam ion trap to q = 8 - 12+ prior to injection into the Penning trap. In combination with the Ramsey excitation scheme, this unique setup creating low energy, highly-charged ions at a radioactive beam facility opens the door to unrivalled precision with gains of 1-2 orders of magnitude. The method is particularly suited for short-lived nuclides such as the superallowed β emitter 74Rb (T1/2 = 65 ms). The determination of its atomic mass and an improved QEC-value are presented.

preprint2011arXiv

PENTATRAP: A novel cryogenic multi-Penning trap experiment for high-precision mass measurements on highly charged ions

The novel five-Penning trap mass spectrometer PENTATRAP is developed at the Max-Planck-Institut für Kernphysik (MPIK), Heidelberg. Ions of interest are long-lived highly charged nuclides up to bare uranium. PENTATRAP aims for an accuracy of a few parts in 10^12 for mass ratios of mass doublets. A physics program for PENTATRAP includes Q-values measurements of β-transitions relevant for neutrino physics, stringent tests of quantum electrodynamics in the regime of extreme electric fields, and a test of special relativity. Main features of PENTATRAP are an access to a source of highly charged ions, a multi-trap configuration, simultaneous measurements of frequencies, a continuous precise monitoring of magnetic field fluctuations, a fast exchange between different ions, and a highly sensitive cryogenic non-destructive detection system. This paper gives a motivation for the new mass spectrometer PENTATRAP, presents its experimental setup, and describes the present status.

preprint2010arXiv

Two-center dielectronic recombination

In the presence of a neighboring atom, electron-ion recombination can proceed resonantly via excitation of an electron in the atom, with subsequent relaxation through radiative decay. It is shown that this two-center dielectronic process can largely dominate over single-center radiative recombination at internuclear distances as large as several nanometers. The relevance of the predicted process is demonstrated by using examples of water-dissolved alkali cations and warm dense matter.

preprint2006arXiv

Potential energy threshold for nano-hillock formation by impact of slow highly charged ions on a CaF$_2$(111) surface

We investigate the formation of nano-sized hillocks on the (111) surface of CaF$_2$ single crystals by impact of slow highly charged ions. Atomic force microscopy reveals a surprisingly sharp and well-defined threshold of potential energy carried into the collision of about 14 keV for hillock formation. Estimates of the energy density deposited suggest that the threshold is linked to a solid-liquid phase transition (``melting&#39;&#39;) on the nanoscale. With increasing potential energy, both the basal diameter and the height of the hillocks increase. The present results reveal a remarkable similarity between the present predominantly potential-energy driven process and track formation by the thermal spike of swift ($\sim$ GeV) heavy ions.