Source author record

J. M. Hogan

J. M. Hogan appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2016arXiv

Response to "Verifying quantum superpositions at metre scales"

The preceding BCA (Stamper-Kurn et. al., arXiv:1607.01454) asserts that our observation of interference contrast in a half-metre-scale atom interferometer (Kovachy et. al., Nature 528, 530-3 (2015)) does not prove the existence of macroscopic quantum superpositions and hence does not test quantum mechanics at long length scales. Moreover, the BCA implies that intrinsic atomic interactions or technical imperfections could prevent the application of our work to future differential measurements. On the contrary, we argue the following: i) in standard quantum mechanics, there is no known mechanism in our system that prohibits its use in future differential measurement applications; ii) our experiment tests quantum mechanics in that it constrains any modifications that would reduce contrast in an interferometer with arms that propagate over widely separated trajectories; and iii) using a standard definition of superposition, our observation of interference results from quantum superposition at the half-metre scale. In particular, quantum superposition is a more general concept than first-order coherence.

preprint2011arXiv

A Precision Angle Sensor using an Optical Lever inside a Sagnac Interferometer

We built an ultra low noise angle sensor by combining a folded optical lever and a Sagnac interferometer. The instrument has a measured noise floor of 1.3 prad / Hz^(1/2) at 2.4 kHz. We achieve this record angle sensitivity using a proof-of-concept apparatus with a conservative N=11 bounces in the optical lever. This technique could be extended to reach sub-picoradian / Hz^(1/2) sensitivities with an optimized design.

preprint2009arXiv

Broadband Optical Serrodyne Frequency Shifting

We demonstrate serrodyne frequency shifting of light from 200 MHz to 1.2 GHz with an efficiency of better than 60 percent. The frequency shift is imparted by an electro-optic phase modulator driven by a high-frequency, high-fidelity sawtooth waveform that is passively generated by a commercially available Non-Linear Transmission Line (NLTL). We also implement a push-pull configuration using two serrodyne-driven phase modulators allowing for continuous tuning between -1.6 GHz and +1.6 GHz. Compared to competing technologies, this technique is simple and robust, and offers the largest available tuning range in this frequency band.