Source author record

J. C. Sun

J. C. Sun appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2019arXiv

Photon statistics and dynamics of nanolasers subject to intensity feedback

Using a fully stochastic numerical scheme, we investigate the behaviour of a nanolaser in the low-coherence regime at the transition between spontaneous emission and lasing under the influence of intensity feedback. Studying the input-output curves as well as the second order correlations for different feedback fractions, we obtain an insight on the role played by the fraction of photons reinjected into the cavity. The interpretation of the observation is strengthened through the comparison with the temporal traces of the emitted photons and with the radiofrequency power spectra. The results give insight into the physics of nanolasers as well as validate the use of the second order autocorrelation as a sufficient tool for the interpretation of the dynamics. This confirmation offers a solid basis for the reliance on autocorrelations in experiments studying the effects of feedback in nanodevices.

preprint2016arXiv

POLAR: Final Calibration and In-Flight Performance of a Dedicated GRB Polarimeter

Gamma-ray polarimetry is a new powerful tool to study the processes responsible for the emission from astrophysical sources and the environments in which this emission takes place. Few successful polarimetric measurements have however been performed thus far in the gamma-ray energy band due to the difficulties involved. POLAR is a dedicated polarimeter designed to perform high precision measurements of the polarization of the emission from gamma-ray burst in the 50-500 keV energy range. This new polarimeter is expected to detect approximately 50 gamma-ray bursts per year while performing high precision polarization measurements on approximately 10 bursts per year. The instrument was launched into lower earth orbit as part of the second Chinese space lab, the Tiangong-2, on September 15th 2016 and has been taking data successfully since being switched on one week after. The instrument uses a segmented scintillator array consisting of 1600 plastic scintillator bars, read out by 25 flat-panel multi-anode photomultipliers, to measure the Compton scattering angles of incoming photons. The small segmentation and relatively large uniform effective area allow the instrument to measure the polarization of a large number of transient events, such as gamma-ray bursts, with an unprecedented precision during its two year life-time. The final flight model underwent detailed calibration prior to launch as well as intensive space qualification tests, a summary of which will be presented in this paper. The instrument design will be discussed first followed by an overview of the on-ground tests, finally the in-orbit behavior as measured during the first weeks of the mission will be presented.

preprint2015arXiv

Calibration of Gamma-ray Burst Polarimeter POLAR

Gamma Ray Bursts (GRBs) are the strongest explosions in the universe which might be associated with creation of black holes. Magnetic field structure and burst dynamics may influence polarization of the emitted gamma-rays. Precise polarization detection can be an ultimate tool to unveil the true GRB mechanism. POLAR is a space-borne Compton scattering detector for precise measurements of the GRB polarization. It consists of a 40$\times$40 array of plastic scintillator bars read out by 25 multi-anode PMTs (MaPMTs). It is scheduled to be launched into space in 2016 onboard of the Chinese space laboratory TG2. We present a dedicated methodology for POLAR calibration and some calibration results based on the combined use of the laboratory radioactive sources and polarized X-ray beams from the European Synchrotron Radiation Facility. They include calibration of the energy response, computation of the energy conversion factor vs. high voltage as well as determination of the threshold values, crosstalk contributions and polarization modulation factors.