Researcher profile

Ioana Pintilie

Ioana Pintilie contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - Baseline
5works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2016arXiv

Dynamic electrical behavior of halide perovskite based solar cells

A dynamic electrical model is introduced to investigate the hysteretic effects in the I-V characteristics of perovskite based solar cells. By making a simple ansatz for the polarization relaxation, our model is able to reproduce qualitatively and quantitatively detailed features of measured I-V characteristics. Pre-poling effects are discussed, pointing out the differences between initially over- and under-polarized samples. In particular, the presence of the current over-shoot observed in the reverse characteristics is correlated with the solar cell pre-conditioning. Furthermore, the dynamic hysteresis is analyzed with respect to changing the bias scan rate, the obtained results being consistent with experimentally reported data: the hysteresis amplitude is maximum at intermediate scan rates, while at very slow and very fast ones it becomes negligible. The effects induced by different relaxation time scales are assessed. The proposed dynamic electrical model offers a comprehensive view of the solar cell operation, being a practical tool for future calibration of tentative microscopic descriptions.

preprint2012arXiv

Challenges for Silicon Pixel Sensors at the European XFEL

A systematic experimental study of the main challenges for silicon-pixel sensors at the European XFEL is presented. The high instantaneous density of X-rays and the high repetition rate of the XFEL pulses result in signal distortions due to the plasma effect and in severe radiation damage. The main parameters of X-ray-radiation damage have been determined and their impact on p+n sensors investigated. These studies form the basis of the optimized design of a pixel-sensor for experimentation at the European XFEL.

preprint2012arXiv

Investigation of X-ray induced radiation damage at the Si-SiO2 interface of silicon sensors for the European XFEL

Experiments at the European X-ray Free Electron Laser (XFEL) require silicon pixel sensors which can withstand X-ray doses up to 1 GGy. For the investigation of X-ray radiation damage up to these high doses, MOS capacitors and gate-controlled diodes built on high resistivity n-doped silicon with crystal orientations <100> and <111> produced by two vendors, CiS and Hamamatsu, have been irradiated with 12 keV X-rays at the DESY DORIS III synchrotron light source. Using capacitance/conductance-voltage, current-voltage and thermal dielectric relaxation current measurements, the surface densities of oxide charges and interface traps at the Si-SiO2 interface, and the surface-current densities have been determined as function of dose. Results indicate that the dose dependence of the surface density of oxide charges and the surface-current density depend on the crystal orientation and producer. In addition, the influence of the voltage applied to the gates of the MOS capacitor and the gate-controlled diode during X-ray irradiation on the surface density of oxide charges and the surface-current density has been investigated at doses of 100 kGy and 100 MGy. It is found that both strongly depend on the gate voltage if the electric field in the oxide points from the surface of the SiO2 to the Si-SiO2 interface. Finally, annealing studies have been performed at 60 and 80 degree C on MOS capacitors and gate-controlled diodes irradiated to 5 MGy and the annealing kinetics of oxide charges and surface current determined.

preprint2012arXiv

Study of radiation damage induced by 12 keV X-rays in MOS structures built on high resistivity n-type silicon

Imaging experiments at the European X-ray Free Electron Laser (XFEL) require silicon pixel sensors with extraordinary performance specifications: Doses of up to 1 GGy of 12 keV photons, up to 10^5 12 keV photons per pixel of 200 \mum \times 200 \mum arriving within less than 100 fs, and a time interval between XFEL pulses of 220 ns. To address these challenges, in particular the question of radiation damage, the properties of the SiO_2 layer and of the Si-SiO_2 interface using MOS capacitors manufactured on high resistivity n-type silicon irradiated to X-ray doses between 10 kGy and 1 GGy, have been studied. Measurements of Capacitance/Conductance-Voltage (C/G-V) at different frequencies, as well as Thermal Dielectric Relaxation Current (TDRC) have been performed. The data can be described by a radiation dependent oxide charge density and three dominant radiation-induced interface states with Gaussian-like energy distributions in the silicon band gap. It is found that the densities of the fixed oxide charges and of the three interface states increase up to dose values of approximately 10 MGy and then saturate or even decrease. The shapes and the frequency dependences of the C/G-V measurements can be quantitatively described by a simple model using the parameters extracted from the TDRC measurements.

preprint2011arXiv

Study of X-ray Radiation Damage in Silicon Sensors

The European X-ray Free Electron Laser (XFEL) will deliver 30,000 fully coherent, high brilliance X-ray pulses per second each with a duration below 100 fs. This will allow the recording of diffraction patterns of single complex molecules and the study of ultra-fast processes. Silicon pixel sensors will be used to record the diffraction images. In 3 years of operation the sensors will be exposed to doses of up to 1 GGy of 12 keV X-rays. At this X-ray energy no bulk damage in silicon is expected. However fixed oxide charges in the insulating layer covering the silicon and interface traps at the Si-SiO2 interface will be introduced by the irradiation and build up over time. We have investigated the microscopic defects in test structures and the macroscopic electrical properties of segmented detectors as a function of the X-ray dose. From the test structures we determine the oxide charge density and the densities of interface traps as a function of dose. We find that both saturate (and even decrease) for doses between 10 and 100 MGy. For segmented sensors the defects introduced by the X-rays increase the full depletion voltage, the surface leakage current and the inter-pixel capacitance. We observe that an electron accumulation layer forms at the Si-SiO2 interface. Its width increases with dose and decreases with applied bias voltage. Using TCAD simulations with the dose dependent parameters obtained from the test structures, we are able to reproduce the observed results. This allows us to optimize the sensor design for the XFEL requirements.