Source author record

Igor Jovanovic

Igor Jovanovic appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

9works
8topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2022arXiv

Passive low energy nuclear recoil detection with color centers -- PALEOCCENE

The PALEOCCENE concept offers the potential for room-temperature, passive and robust detectors in the gram to kilogram range for the detection of low-energy nuclear recoil events. Nuclear recoil events can be caused by neutron scattering, coherent elastic neutrino nucleus scattering (CEvNS) or dark matter scattering and therefore, PALEOCCENE could find applications in all three areas. In this white paper we present current and planned R&D efforts to study the feasibility of this technique.

preprint2022arXiv

Performance of Hamamatsu VUV4 SiPMs for detecting liquid argon scintillation

Detection of light signals is crucial to a wide range of particle detectors. In particular, efficient detection of vacuum ultraviolet (VUV) light will provide new opportunities for some novel detectors currently being developed, but is technically challenging. In this article, we characterized the performance of Hamamatsu VUV4 silicon photomultipliers (SiPMs) for detecting VUV argon scintillation light without wavelength shifting. Using a customized cryogenic amplifier design, we operated two models of VUV4 SiPMs inside liquid argon and thoroughly examined their direct sensitivities to liquid argon scintillation. In addition to describing their cryogenic performance, we measured a photon detection efficiency of $14.7^{+1.1}_{-2.4}$% and $17.2^{+1.6}_{-3.0}$% at 128 nm for these two VUV4 models for operation at 4 V of overvoltage, with the main uncertainty arising from the SiPM reflectivity for VUV light.

preprint2020arXiv

Discriminating Uranium Isotopes Based on Fission Signatures Induced by Delayed Neutrons

The use of active interrogation (AI) to induce delayed neutron emission is a well-established technique for the characterization of special nuclear materials (SNM). Delayed neutrons have isotope-characteristic spectral and temporal signatures, which provide the basis for isotope identification. However, in bulk materials that contain an appreciable fissile (e.g., $^{235}$U or $^{233}$U) fraction, such as highly-enriched uranium (HEU), delayed neutrons have a high probability of inducing additional fissions. As a result, the overall delayed neutron signature consists of two distinct components: the "primary" delayed neutrons (emitted directly by fission fragments), and the "secondary prompt" fission neutrons produced in fission induced by primary delayed neutrons. These prompt products differ from "primary" delayed neutrons both in their energy spectra and in the presence of coincident radiation released by the parent fission event. The presence and relative quantity of prompt products from delayed fission depend on the cross-section of the material in the energy range of delayed neutrons, which may differ significantly between isotopes, thus providing an exploitable means for isotope differentiation. In this work, we demonstrate two experimental approaches for discriminating between $^{235}$U and $^{238}$U isotopes based on the measurement of delayed neutron-induced fission products. First, HEU and depleted uranium objects are differentiated through the detection of high-energy prompt neutrons from delayed fission using both recoil-based organic liquid scintillators and thermalization spectra from a custom-built capture-gated composite detector. Secondly, coincident radiation measurements are used as the basis for discrimination by comparing the overall rates and time evolution of fission events when delayed neutrons are present.

preprint2020arXiv

Neutrino Detectors as Tools for Nuclear Security

For over 40 years, physicists have considered possible uses for neutrino detectors in nuclear nonproliferation, arms control, and fissile materials security. Neutrinos are an attractive fission signature because they readily pass through matter. The same property makes neutrinos challenging to detect in systems that would be practical for nuclear security applications. This colloquium presents a broad overview of several potential neutrino applications, including the near-field monitoring of known reactors, far-field monitoring of known or discovery of undeclared reactors, detection of reactor waste streams, and detection of nuclear explosions. We conclude that recent detector advances have made near-field monitoring feasible. Farther-field reactor detection and waste stream detection monitoring are possible in some cases with further research and development. Very long-range reactor monitoring and nuclear explosion detection do not appear feasible for the foreseeable future due to considerable physical and/or practical constraints.

preprint2015arXiv

Gate-tunable and high responsivity graphene phototransistors on undoped semiconductor substrates

Due to its high charge carrier mobility, broadband light absorption, and ultrafast carrier dynamics, graphene is a promising material for the development of high-performance photodetectors. Graphene-based photodetectors have been demonstrated to date using monolayer graphene operating in conjunction with either metals or semiconductors. Most graphene devices are fabricated on doped Si substrates with SiO2 dielectric used for back gating. Here, we demonstrate photodetection in graphene field effect phototransistors fabricated on undoped semiconductor (SiC) substrates. The photodetection mechanism relies on the high sensitivity of the graphene conductivity to the local change of the electric field that can result from the photo-excited charge carriers produced in the back-gated semiconductor substrate. We also modeled the device and simulated its operation using the finite element method to validate the existence of the field induced photoresponse mechanism and study its properties. Our graphene phototransistor possesses a room-temperature photoresponsivity as high as ~ 7.4 A/W, higher than the required photoresponsivity (1 A/W) in most practical applications. The light power-dependent photocurrent and photoresponsivity can be tuned by the source-drain bias voltage and back-gate voltage. Graphene phototransistors based on this simple and generic architecture can be fabricated by depositing graphene on a variety of undoped substrates, and are attractive for many applications in which photodetection or radiation detection is sought.

preprint2014arXiv

Low-Energy (<10 keV) Electron Ionization and Recombination Model for a Liquid Argon Detector

Detailed understanding of the ionization process in noble liquid detectors is important for their use in applications such as the search for dark matter and coherent elastic neutrino-nucleus scattering. The response of noble liquid detectors to low-energy ionization events is poorly understood at this time. We describe a new simulation tool which predicts the ionization yield from electronic energy deposits (E < 10keV) in liquid Ar, including the dependence of the yield on the applied electric drift field. The ionization signal produced in a liquid argon detector from $^{37}$Ar beta decay and $^{55}$Fe X-rays has been calculated using the new model.

preprint2010arXiv

Effect of electron-beam irradiation on graphene field effect devices

Electron beam exposure is a commonly used tool for fabricating and imaging graphene-based devices. Here we present a study of the effects of electron-beam irradiation on the electronic transport properties of graphene and the operation of graphene field-effect transistors (GFET). Exposure to a 30 keV electron-beam caused negative shifts in the charge-neutral point (CNP) of the GFET, interpreted as due to n-doping in the graphene from the interaction of the energetic electron beam with the substrate. The shift of the CNP is substantially reduced for suspended graphene devices. The electron beam is seen to also decrease the carrier mobilities and minimum conductivity, indicating defects created in the graphene. The findings are valuable for understanding the effects of radiation damage on graphene and for the development of radiation-hard graphene-based electronics.

preprint2010arXiv

Scanning Gate Microscopy on Graphene: Charge Inhomogeneity and Extrinsic Doping

We have performed scanning gate microscopy (SGM) on graphene field effect transistors (GFET), using a biased metallic nanowire coated with a dielectric layer as a contact mode tip and local top gate. Electrical transport through graphene at various back gate voltages is monitored as a function of tip voltage and tip position. Near the Dirac point, the dependence of graphene resistance on tip voltage shows a significant variation with tip position. SGM imaging reveals mesoscopic domains of electron-doped and hole-doped regions. Our measurements indicate a substantial spatial fluctuation (on the order of 10^12/cm^2) in the carrier density in graphene due to extrinsic local doping. Important sources for such doping found in our samples include metal contacts, edges of graphene, structural defects, and resist residues.

preprint2009arXiv

Operation of a 1-Liter-Volume Gaseous Argon Scintillation Counter

We have built a gas-phase argon ionization detector to measure small nuclear recoil energies (< 10 keVee). In this paper, we describe the detector response to X-ray and gamma calibration sources, including analysis of pulse shapes, software triggers, optimization of gas content, and energy- and position-dependence of the signal. We compare our experimental results against simulation using a 5.9-keV X-ray source, as well as higher-energy gamma sources up to 1332 keV. We conclude with a description of the detector, DAQ, and software settings optimized for a measurement of the low-energy nuclear quenching factor in gaseous argon. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory in part under Contract W-7405-Eng-48 and in part under Contract DE-AC52-07NA27344. Funded by Lab-wide LDRD. LLNL-JRNL-415990-DRAFT.