Source author record

Atena Darvishi

Atena Darvishi appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Hierarchical Frequency and Voltage Control using Prioritized Utilization of Inverter Based Resources

We propose a novel hierarchical frequency and voltage control design for multi-area power system integrated with inverter-based resources (IBRs). The design is based on the idea of prioritizing the use of IBRs over conventional generator-based control in compensating for sudden and unpredicted changes in loads and generations, and thereby mitigate any undesired dynamics in the frequency or the voltage by exploiting their fast actuation time constants. A new sequential optimization problem, referred to as Area Prioritized Power Flow (APPF), is formulated to model this prioritization. It is shown that compared to conventional power flow APPF not only leads to a fairer balance between the dispatch of active and reactive power from the IBRs and the synchronous generators, but also limits the impact of any contingency from spreading out beyond its respective control area, thereby guaranteeing a better collective dynamic performance of the grid. This improvement, however, comes at the cost of adding an extra layer of communication needed for executing APPF in a hierarchical way. Results are validated using simulations of a 9-machine, 6-IBR, 33-bus, 3-area power system model, illustrating how APPF can mitigate a disturbance faster and more efficiently by prioritizing the use of local area-resources.

preprint2014arXiv

Synchrophasor monitoring of single line outages via area angle and susceptance

The area angle is a scalar measure of power system area stress that responds to line outages within the area and is a combination of synchrophasor measurements of voltage angles around the border of the area. Both idealized and practical examples are given to show that the variation of the area angle for single line outages can be approximately related to changes in the overall susceptance of the area and the line outage severity.

preprint2014arXiv

Threshold-based monitoring of cascading outages with PMU measurements of area angle

When power grids are heavily stressed with a bulk power transfer, it is useful to have a fast indication of the increased stress when multiple line outages occur. Reducing the bulk power transfer when the outages are severe could forestall further cascading of the outages. We show that synchrophasor measurements of voltage angles at all the area tie lines can be used to indicate the severity of multiple outages. These synchrophasor measurements are readily combined into an "area angle" that can quickly track the severity of multiple outages after they occur. We present a procedure to define thresholds for the area angle that relate to the maximum power that can be transferred through the area until a line limit is reached. Then in real time we would monitor the area angle and compare it to the thresholds when line outages occur to determine the urgency (or not) of actions to reduce the bulk transfer of power through the area. The procedure also identifies exceptional cases in which separate actions to resolve local power distribution problems are needed. We illustrate the thresholds and monitoring with the area angle across several states of Northwestern USA.