Researcher profile

I. Alexandrov

I. Alexandrov contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2010arXiv

Direct observation of avalanche scintillations in a THGEM-based two-phase Ar avalanche detector using Geiger-mode APD

A novel concept of optical signal recording in two-phase avalanche detectors, with Geiger-mode Avalanche Photodiodes (G-APD) is described. Avalanche-scintillation photons were measured in a thick Gas Electron Multiplier (THGEM) in view of potential applications in rare-event experiments. The effective detection of avalanche scintillations in THGEM holes has been demonstrated in two-phase Ar with a bare G-APD without wavelength shifter, i.e. insensitive to VUV emission of Ar. At gas-avalanche gain of 400 and under \pm 70^\circ viewing-angle, the G-APD yielded 640 photoelectrons (pe) per 60 keV X-ray converted in liquid Ar; this corresponds to 0.7 pe per initial (prior to multiplication) electron. The avalanche-scintillation light yield measured by the G-APD was about 0.7 pe per avalanche electron, extrapolated to 4pi acceptance. The avalanche scintillations observed occurred presumably in the near infrared (NIR) where G-APDs may have high sensitivity. The measured scintillation yield is similar to that observed by others in the VUV. Other related topics discussed in this work are the G-APD's single-pixel and quenching resistor characteristics at cryogenic temperatures.

preprint2010arXiv

Geiger Mode APD performance in a cryogenic two-phase Ar avalanche detector based on THGEMs

Characteristic properties of a Geiger Mode APD (G-APD) in a THGEM-based cryogenic two-phase Ar avalanche detector were studied in view of potential applications in rare-event experiments. G-APD signal amplitude and noise characteristics at cryogenic temperatures turned out to be superior to those at room temperature. The effective detection of avalanche scintillations from THGEM-multiplier holes in two-phase Ar has been demonstrated using a G-APD without wavelength shifter. At an avalanche gain of 60, the avalanche scintillation yield measured by the G-APD was as high as 0.9 photoelectrons per avalanche electron, extrapolated to 4pi acceptance.