Researcher profile

A. Buzulutskov

A. Buzulutskov contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
9works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2022arXiv

Study of visible-light emission in pure and methane-doped liquid argon

In liquid argon TPCs for dark matter search and neutrino detection experiments, primary scintillation light is used as a prompt signal of particle scattering, being intensively produced in the vacuum ultraviolet (VUV) due to excimer emission mechanism. On the other hand, there were indications on the production of visible-light emission in liquid argon, albeit at a much lower intensity, the origin of which is still not clear. The closely related issue is visible-light emission in liquid argon doped with methane, the interest in which is due to the possible use in neutron veto detectors for those experiments. In this work we study in detail the properties of such light emission in pure liquid argon and its mixtures with methane. In particular, the absolute photon yield of visible-light emission in pure liquid argon was measured to be about 200 and 90 photon/MeV for X-rays and alpha particles respectively. In liquid argon doped with methane the photon yield dropped down significantly, by about an order of magnitude at a methane molar content varying from 0.01 to 1%, and then almost did not change when further increasing the methane content up to 10%.

preprint2021arXiv

Neutral bremsstrahlung electroluminescence in noble liquids

Proportional electroluminescence (EL) is the physical effect used in two-phase dark matter detectors, to optically record in the gas phase the ionization signal produced by particle scattering in the liquid phase. In our previous works the presence of a new EL mechanism in noble gases, namely that of neutral bremsstrahlung (NBrS), was demonstrated both theoretically and experimentally, in addition to the ordinary EL mechanism due to excimer emission. In this work we show that the similar theoretical approach can apply to noble liquids, namely to liquid helium, neon, argon, krypton and xenon. In particular, the photon yields and spectra for NBrS EL in noble liquids have for the first time been calculated, using the electron energy and transport parameters obtained in the framework of Cohen-Lekner and Atrazhev theory. The relevance of the results obtained to the development of noble liquid detectors for dark matter searches and neutrino experiments is discussed.

preprint2021arXiv

SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range

Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the visible and near infrared (NIR) ranges. The first is due to bremsstrahlung of electrons scattered on neutral atoms ("neutral bremsstrahlung", NBrS). The second, responsible for electron avalanche scintillation in the NIR at higher electric fields, is due to transitions between excited atomic states. In this work, we have for the first time demonstrated two alternative techniques of the optical readout of two-phase argon detectors, in the visible and NIR range, using a silicon photomultiplier matrix and electroluminescence due to either neutral bremsstrahlung or avalanche scintillation. The amplitude yield and position resolution were measured for these readout techniques, which allowed to assess the detection threshold for electron and nuclear recoils in two-phase argon detectors for dark matter searches. To the best of our knowledge, this is the first practical application of the NBrS effect in detection science.

preprint2020arXiv

Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon

Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, $^{39}$Ar, a $β$ emitter of cosmogenic origin. For large detectors, the atmospheric $^{39}$Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of $^{39}$Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of $^{39}$Ar with respect to AAr by a factor larger than 1400. Assessing the $^{39}$Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly $γ$-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.

preprint2020arXiv

Electroluminescence and electron avalanching in two-phase detectors

Electroluminescence and electron avalanching are the physical effects used in two-phase argon and xenon detectors for dark mater search and neutrino detection, to amplify the primary ionization signal directly in cryogenic noble-gas media. We review the concepts of such light and charge signal amplification, including a combination thereof, both in the gas and in the liquid phase. Puzzling aspects of the physics of electroluminescence and electron avalanching in two-phase detectors are explained and detection techniques based on these effects are described.

preprint2020arXiv

Observation of primary scintillations in the visible range in liquid argon doped with methane

Neutron veto detector based on liquid scintillator containing hydrogen atoms is an integral part of any underground experiment for dark matter search. So far, a flammable mixture of liquid hydrocarbons was used as a liquid scintillator in such detectors. A safe alternative might be a liquid scintillator based on liquid argon doped with methane. In this work, we have studied the primary scintillations in pure liquid argon and its mixtures with methane, the CH4 content varying from 100 ppm to 5%. The primary scintillations have for the first time been observed in liquid argon doped with methane, in the visible and near infrared range, and their relative light yields have been measured as a function of the CH4 content.

preprint2020arXiv

Observation of unusual slow components in electroluminescence signal of two-phase argon detector

Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter search to record ionization signals in the gas phase induced by particle scattering in the liquid phase (S2 signals). In this work, the EL pulse-shapes in a two-phase argon detector have for the first time been studied systematically in a wide range of reduced electric field, varying from 3 to 9 Td. The pulse-shapes were studied at different readout configurations and spectral ranges: using cryogenic PMTs and SiPMs, with and without a wavelength shifter (WLS), in the VUV and visible range. We observed the fast component and two unusual slow components, with time constants of about 5 $μ$s and 40 $μ$s. The unusual characteristic property of slow components was that their contribution and time constants increased with electric field.

preprint2019arXiv

Ion detector for Accelerator Mass Spectrometry based on low-pressure TPC with THGEM readout

A new technique for ion identification in Accelerator Mass Spectrometry (AMS) has been proposed by measuring the ion track ranges using a low-pressure TPC. As a proof of principle, a low-pressure TPC with charge readout using a THGEM multiplier was developed. The tracks of alpha particles from various radioactive sources were successfully recorded in the TPC. The track ranges were measured with a high accuracy, reaching the 2% resolution level. Using these results and the SRIM code simulation, it is shown that the isobaric boron and beryllium ions can be effectively separated at ten sigma level. It is expected that this technique will be applied in the AMS facility in Novosibirsk for dating geological objects, in particular for the geochronology of Cenozoic Era.

preprint2019arXiv

Neutral bremsstrahlung in two-phase argon electroluminescence: further studies and possible applications

We further study the effect of neutral bremsstrahlung (NBrS) in two-phase argon electroluminescence (EL), revealed recently in [1]. The absolute EL yield due to NBrS effect, in the visible and NIR range, was remeasured in pure gaseous argon in the two-phase mode, using a two-phase detector with EL gap read out directly by cryogenic PMTs and SiPMs. Possible applications of the NBrS effect in detection science are discussed, including those in two-phase dark matter detectors.