Researcher profile

Huizhu Hu

Huizhu Hu contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Displacement calibration of optical tweezers with absolute gravitational acceleration

In recent years, levitated particles of optical traps in vacuum have shown enormous potential in precision sensor development and searching for new physics. The accuracy of the calibration relating the detected signal to absolute displacement of the trapped particle is a critical factor for absolute measurement performance. In this paper, we suggest and experimentally demonstrate a novel calibration method for optical tweezers based on free-falling particles in vacuum, where the gravitational acceleration is introduced as an absolute reference. Our work provides a calibration protocol with great certainty and traceability, which is significant in improving the accuracy of precision sensing based on optically levitated particles.

preprint2022arXiv

Nanoscale Electric Field Sensing Using Levitated Nano-resonator with Net Charge

Nanomechanical resonator based on levitated particle exhibits unique advantages in the development of ultrasensitive electric field detector. We demonstrate a three-dimensional, high-sensitivity electric field measurement technology using the optically levitated nanoparticle with a known net charge. By changing the relative position between nanoparticle and parallel electrodes, the three-dimensional electric field distribution is scanned. The measured noise equivalent electric intensity with charge amount of 100 reaches the order of {\rm{1μV/cm/H}}{\rm{z}^{\rm{1/2}}} at 1.4 \times {10^{ - 7}}mbar. Linearity analysis near resonance frequency shows a measured linear range over 91dB limited only by the maximum output voltage of the driving equipment. This work may provide avenue for developing a high-sensitive electric field sensor based on optically levitated nano-resonator.

preprint2021arXiv

Force Detection Sensitivity Spectrum Calibration of Levitated Nanomechanical Sensor Using Harmonic Coulomb Force

Oscillators based on levitated particles are promising for the development of ultrasensitive force detectors. The theoretical performance of levitated nanomechanical sensors is usually characterized by the so-called thermal noise limit force detection sensitivity, which does not exhibit spectral specificity in practical measurements. To characterize the actual detection performance, we propose a method for the force detection sensitivity calibration of a levitated nanomechanical sensor based on the harmonic Coulomb force. Utilizing the measured transfer function, we obtained the force detection sensitivity spectrum from the position spectrum. Although the thermal noise limit force detection sensitivity of the system reached $\rm\left( {4.39 \pm 0.62} \right) \times {10^{ - 20}} N/H{z^{1/2}}$ at $\rm{2.4\times10^{-6} mbar}$ with feedback cooling, the measured sensitivity away from the resonance was of the order of $\rm10^{-17} N/Hz^{1/2}$ based on the existing detection noise level. The calibration method established in our study is applicable to the performance evaluation of any optical levitation system for high-sensitivity force measurements.