Researcher profile

Heping Zeng

Heping Zeng contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Broadband Terahertz Quantum Cascade Laser Dual-Comb Sources with Off-Resonant Microwave Injection

Broadband dual-comb spectroscopy has attracted increasing interests due to its unique advantages in high spectral resolution, fast detection, and so on. Although the dual-comb technique is relatively mature in the infrared wavelengths, it is, currently, not commercially capable of practical applications in the terahertz regime due to the lack of high performance broadband terahertz dual-comb sources. In the terahertz frequency range, the electrically pumped quantum cascade laser (QCL) is a suitable candidate for the dual-comb operation. However, free running terahertz QCL dual-comb sources normally show limited optical bandwidths ($\sim$100-200 GHz). Although the resonant microwave injection locking has been widely used to broaden the emission spectra of terahertz QCLs by modulating the laser drive current at the cavity round-trip frequency, it is hard to be employed to broaden the dual-comb bandwidths due to the large phase noise induced by the resonant injection and non-ideal microwave circuits. Therefore, it is challenging to obtain broadband terahertz dual-comb sources that can fully exploits the laser gain bandwidth. Here, we employ an off-resonant microwave injection to significantly broaden the dual-comb bandwidth of a terahertz QCL dual-comb source emitting around 4.2 THz. The measured optical dual-comb bandwidth is broadened from 147 GHz in free running to $>$450 GHz under the off-resonant injection. The broadened dual-comb bandwidth is experimentally proved by the transmission measurements of a filter and a GaAs etalon. By performing a simple numerical analysis based on a rate equation model, we explain that the broadband dual-comb operation under the off-resonant microwave injection could be resulted from a wider lasing bandwidth and a higher degree of phase matching.

preprint2019arXiv

Towards Compact and Real-Time Terahertz Dual-Comb Spectroscopy Employing a Self-Detection Scheme

Due to its fast and high resolution characteristics, dual-comb spectroscopy has attracted an increasing amount of interest since its first demonstration. In the terahertz frequency range where abundant absorption lines (finger prints) of molecules are located, multiheterodyne spectroscopy that employs the dual-comb technique shows an advantage in real-time spectral detection over the traditional Fourier transform infrared or time domain spectroscopies. Here, we demonstrate compact terahertz dual-comb spectroscopy based on quantum cascade lasers (QCLs). In our experiment, two free-running QCLs generate approximately 120 GHz wide combs centered at 4.2 THz, with slightly different repetition frequencies. We observe that $\sim$490 nW terahertz power coupling of one laser into the other suffices for laser-self-detecting the dual-comb spectrum that is registered by a microwave spectrum analyzer. Furthermore, we demonstrate practical terahertz transmission dual-comb spectroscopy with our device, by implementing a short air path at room temperature. Spectra are shown of semiconductor samples and of moist air, the latter allowing rapid monitoring of the relative humidity. Our devices should be readily extendable to perform imaging, microscopy and near-field microscopy in the terahertz regime.

preprint2007arXiv

Room temperature triggered single-photon source in the near infrared

We report the realization of a solid-state triggered single-photon source with narrow emission in the near infrared at room temperature. It is based on the photoluminescence of a single nickel-nitrogen NE8 colour centre in a chemical vapour deposited diamond nanocrystal. Stable single-photon emission has been observed in the photoluminescence under both continuous-wave and pulsed excitations. The realization of this source represents a step forward in the application of diamond-based single-photon sources to Quantum Key Distribution (QKD) under practical operating conditions.