Source author record

Henry J. Frisch

Henry J. Frisch appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2024arXiv

Simulation of a Compton-based detector for low-dose high-resolution time-of-flight positron emission tomography

Two major challenges in time-of-flight positron emission tomography (TOF-PET) are low spatial resolution and high radioactive dose to the patient, both of which result from limitations in detection technology rather than fundamental physics. A new type of TOF-PET detector employing low-atomic number (low-Z) scintillation media and large-area, high-resolution photodetectors to record Compton scattering locations in the detector has been proposed as a promising alternative, but the minimum technical requirements for such a system have not yet been established. Here we present a simulation study evaluating the potential of a proposed low-Z detection medium, linear alkylbenzene (LAB) doped with a switchable molecular recorder, for next-generation TOF-PET detection. We developed a custom Monte Carlo simulation of full-body TOF-PET using the TOPAS Geant4 software package. By quantifying contributions and tradeoffs for energy, spatial, and timing resolution of the detector, we show that at reasonable combination of specifications, our likelihood-based identification of pairs of first interaction locations in the simulated detector identifies 87.1% of pairs with zero or negligible error, and correctly rejects 90% of all in-patient scatters. The same specifications give TOF-PET sensitivity of ~66.7% and PSF width 4.6 mm with clear contrast. A detector with these specifications provides a clear image of a brain phantom simulated at less than 1% of a standard radiotracer dose.

preprint2020arXiv

Measuring the Neutrino Event Time in Liquid Argon by a Post-Reconstruction One-parameter Fit

We propose a relatively simple method to measure the event time in liquid Argon (LAr) TPC-based neutrino detectors that takes advantage of the topological reconstruction of each event from the TPC data prior to performing a one-parameter fit. Measured times and positions of detected photons are fit to the expected pattern of light from the tracks as reconstructed using the electron drift. The event can be treated as a rigid body with only the neutrino interaction time as a free parameter. The optical properties of LAr are comparable to those of water for Cherenkov light in visible wavelengths. Data-Monte Carlo comparisons of the light patterns, given the known track topology from electron drift, enable in situ calibration of the optical model and further optimization of the timing. A back-of-the-envelope calculation predicts that the single parameter fit for the interaction time requires a significantly lower photodetector coverage than needed for the same precision in conventional warm-liquid detectors.

preprint2016arXiv

A Brief Technical History of the Large-Area Picosecond Photodetector (LAPPD) Collaboration

The Large Area Picosecond PhotoDetector (LAPPD) Collaboration was formed in 2009 to develop large-area photodetectors capable of time resolutions measured in pico-seconds, with accompanying sub-millimeter spatial resolution. During the next three and one-half years the Collaboration developed the LAPPD design of 20 x 20 cm modules with gains greater than $10^7$ and non-uniformity less than $15\%$, time resolution less than 50 psec for single photons and spatial resolution of 700~microns in both lateral dimensions. We describe the R\&D performed to develop large-area micro-channel plate glass substrates, resistive and secondary-emitting coatings, large-area bialkali photocathodes, and RF-capable hermetic packaging. In addition, the Collaboration developed the necessary electronics for large systems capable of precise timing, built up from a custom low-power 15-GigaSample/sec waveform sampling 6-channel integrated circuit and supported by a two-level modular data acquisition system based on Field-Programmable Gate Arrays for local control, data-sparcification, and triggering. We discuss the formation, organization, and technical successes and short-comings of the Collaboration. The Collaboration ended in December 2012 with a transition from R\&D to commercialization.