Source author record

Harald Lück

Harald Lück appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

9works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2022arXiv

Improving the stability of frequency dependent squeezing with bichromatic control of filter cavity length, alignment and incident beam pointing

Frequency dependent squeezing is the main upgrade for achieving broadband quantum noise reduction in upcoming observation runs of gravitational wave detectors. The proper frequency dependence of the squeezed quadrature is obtained by reflecting squeezed vacuum from a Fabry-Perot filter cavity detuned by half of its linewidth. However, since the squeezed vacuum contains no classical amplitude, co-propagating auxiliary control beams are required to achieve the filter cavity's length, alignment, and incident beam pointing stability. In our frequency dependent squeezing experiment at the National Astronomical Observatory of Japan, we used a control beam at a harmonic of squeezed vacuum wavelength and found visible detuning variation related to the suspended mirrors angular drift. These variations can degrade interferometer quantum noise reduction. We investigated various mechanisms that can cause the filter cavity detuning variation. The detuning drift is found to be mitigated sufficiently by fixing the incident beam pointing and applying filter cavity automatic alignment. It was also found that there is an optimal position of the beam on the filter cavity mirror that helps to reduce the detuning fluctuations. Here we report a stabilized filter cavity detuning variation of less than 10$\,$Hz compared to the 113$\,$Hz cavity linewidth. Compared to previously published results [Phys. Rev. Lett. 124, 171101 (2020)], such detuning stability would be sufficient to make filter cavity detuning drift induced gravitational wave detector detection range fluctuation reduce from $11\%$ to within $2\%$.

preprint2021arXiv

Direct limits for scalar field dark matter from a gravitational-wave detector

The nature of dark matter remains unknown to date; several candidate particles are being considered in a dynamically changing research landscape. Scalar field dark matter is a prominent option that is being explored with precision instruments, such as atomic clocks and optical cavities. Here we report on the first direct search for scalar field dark matter utilising a gravitational-wave detector, which operates beyond the quantum shot-noise limit. We set new upper limits for the coupling constants of scalar field dark matter as a function of its mass, by excluding the presence of signals that would be produced through the direct coupling of this dark matter to the beamsplitter of the GEO$\,$600 interferometer. The new constraints improve upon bounds from previous direct searches by more than six orders of magnitude, and are in some cases more stringent than limits obtained in tests of the equivalence principle by up to four orders of magnitude. Our work demonstrates that scalar field dark matter can be probed or constrained with direct searches using gravitational-wave detectors, and highlights the potential of quantum-enhanced interferometry for dark matter detection.

preprint2020arXiv

Bilinear noise subtraction at the GEO 600 observatory

Longitudinal control signals used to keep gravitational wave detectors at a stable operating point are often affected by modulations from test mass misalignments leading to an elevated noise floor ranging from 50 to 500 Hz. Nonstationary noise of this kind results in modulation sidebands and increases the number of glitches observed in the calibrated strain data. These artifacts ultimately affect the data quality and decrease the efficiency of the data analysis pipelines looking for astrophysical signals from continuous waves as well as the transient events. In this work, we develop a scheme to subtract one such bilinear noise from the gravitational wave strain data and demonstrate it at the GEO 600 observatory. We estimate the coupling by making use of narrow-band signal injections that are already in place for noise projection purposes and construct a coherent bilinear signal by a two-stage system identification process. We improve upon the existing filter design techniques by employing a Bayesian adaptive directed search strategy that optimizes across the several key parameters that affect the accuracy of the estimated model. The scheme takes into account the possible nonstationarities in the coupling by periodically updating the involved filter coefficients. The resulting postoffline subtraction leads to a suppression of modulation sidebands around the calibration lines along with a broadband reduction of the midfrequency noise floor. The observed increase in the astrophysical range and a reduction in the occurrence of nonastrophysical transients suggest that the above method is a viable data cleaning technique for current and future generation gravitational wave observatories.

preprint2020arXiv

First demonstration of 6 dB quantum noise reduction in a kilometer scale gravitational wave observatory

Photon shot noise, arising from the quantum-mechanical nature of the light, currently limits the sensitivity of all the gravitational wave observatories at frequencies above one kilohertz. We report a successful application of squeezed vacuum states of light at the GEO\,600 observatory and demonstrate for the first time a reduction of quantum noise up to $6.03 \pm 0.02$ dB in a kilometer-scale interferometer. This is equivalent at high frequencies to increasing the laser power circulating in the interferometer by a factor of four. Achieving this milestone, a key goal for the upgrades of the advanced detectors, required a better understanding of the noise sources and losses, and implementation of robust control schemes to mitigate their contributions. In particular, we address the optical losses from beam propagation, phase noise from the squeezing ellipse, and backscattered light from the squeezed light source. The expertise gained from this work carried out at GEO 600 provides insight towards the implementation of 10 dB of squeezing envisioned for third-generation gravitational wave detectors.

preprint2020arXiv

Frequency-Dependent Squeezed Vacuum Source for Broadband Quantum Noise Reduction in Advanced Gravitational-Wave Detectors

The astrophysical reach of current and future ground-based gravitational-wave detectors is mostly limited by quantum noise, induced by vacuum fluctuations entering the detector output port. The replacement of this ordinary vacuum field with a squeezed vacuum field has proven to be an effective strategy to mitigate such quantum noise and it is currently used in advanced detectors. However, current squeezing cannot improve the noise across the whole spectrum because of the Heisenberg uncertainty principle: when shot noise at high frequencies is reduced, radiation pressure at low frequencies is increased. A broadband quantum noise reduction is possible by using a more complex squeezing source, obtained by reflecting the squeezed vacuum off a Fabry-Perot cavity, known as filter cavity. Here we report the first demonstration of a frequency-dependent squeezed vacuum source able to reduce quantum noise of advanced gravitational-wave detectors in their whole observation bandwidth. The experiment uses a suspended 300-m-long filter cavity, similar to the one planned for KAGRA, Advanced Virgo and Advanced LIGO, and capable of inducing a rotation of the squeezing ellipse below 100 Hz.

preprint2015arXiv

Birefringence Measurements on Crystalline Silicon

Crystalline silicon has been proposed as a new test mass material in third generation gravitational wave detectors such as the Einstein Telescope (ET). Birefringence can reduce the interferometric contrast and can produce dynamical disturbances in interferometers. In this work we use the method of polarisation-dependent resonance frequency analysis of Fabry-Perot-cavities containing silicon as a birefringent medium. Our measurements show a birefringence of silicon along the (111) axis of the order of $Δ\, n \approx 10^{-7}$ at a laser wavelength of 1550nm and room temperature. A model is presented that explains the results of different settings of our measurements as a superposition of elastic strains caused by external stresses in the sample and plastic strains possibly generated during the production process. An application of our theory on the proposed ET test mass geometry suggests no critical effect on birefringence due to elastic strains.

preprint2013arXiv

Thermal Correction of Astigmatism in the Gravitational Wave Observatory GEO 600

The output port of GEO 600 is dominated by unwanted high order modes (HOMs). The current thermal actuation system, a ring heater behind one of the folding mirrors, causes a significant amount of astigmatism, which produces HOMs. We have built and installed an astigmatism correction system, based on heating this folding mirror at the sides (laterally). With these side heaters and the ring heater behind the mirror, it is possible to tune its radius of curvature in the horizontal and the vertical degree of freedom. We use this system to match the mirrors in the two arms of GEO 600 to each other, thereby reducing the contrast defect. The use of the side heaters reduces the power of the HOMs at the output of GEO 600 by approximately 37%.

preprint2011arXiv

Optical layout for a 10m Fabry-Pérot Michelson interferometer with tunable stability

The sensitivity of high-precision interferometric measurements can be limited by Brownian noise within dielectric mirror coatings. This occurs, for instance, in the optical resonators of gravitational wave detectors where the noise can be reduced by increasing the laser beam size. However, the stability of the resonator and its optical performance often impose a limit on the maximally feasible beam size. In this article we describe the optical design of a 10\,m Fabry-Pérot Michelson interferometer with tunable stability. Our design will allow us to carry out initial commissioning with arm cavities of high stability, while afterwards the arm cavity length can be increased stepwise towards the final, marginally stable configuration. Requiring only minimal hardware changes, with respect to a comparable "static" layout, the proposed technique will not only enable us to explore the stability limits of an optical resonator with realistic mirrors exhibiting inevitable surface imperfections, but also the opportunity to measure coating Brownian noise at frequencies as low as a few hundred Hertz. A detailed optical design of the tunable interferometer is presented and requirements for the optical elements are derived from robustness evaluations.