Researcher profile

Hansjörg Scherer

Hansjörg Scherer contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2016arXiv

Improved Calibration of Instruments for Small Direct Currents

We report on new calibration methods for picoammeters and low-current sources. The "Ultrastable Low-noise Current Amplifier" (ULCA) was used for the exemplary calibration of commercial state-of-the-art ammeter and current source instruments in the current range between 1 femtoampere and 1 microampere. The uncertainties achieved are compared with results obtained from two other calibration methods for small direct currents. It is shown that using the ULCA as calibrator allows achieving lower uncertainties together with the benefit of easier handling compared to alternative techniques. Also, the ULCA allows performing current meter and source calibrations between 1 femtoampere and 1 microampere with a single method.

preprint2015arXiv

Validation of a quantized-current source with 0.2 ppm uncertainty

We report on high-accuracy measurements of quantized current, sourced by a tunable-barrier single-electron pump at frequencies $f$ up to $1$ GHz. The measurements were performed with a new picoammeter instrument, traceable to the Josephson and quantum Hall effects. Current quantization according to $I=ef$ with $e$ the elementary charge was confirmed at $f=545$ MHz with a total relative uncertainty of 0.2 ppm, improving the state of the art by about a factor of 5. For the first time, the accuracy of a possible future quantum current standard based on single-electron transport was experimentally validated to be better than the best realization of the ampere within the present SI.

preprint2015arXiv

Validation of the ultrastable low-noise current amplifier as travelling standard for small direct currents

An interlaboratory comparison of small-current generation and measurement capability is presented with the ultrastable low-noise current amplifier (ULCA) acting as travelling standard. Various measurements at direct currents between 0.16 nA and 13 nA were performed to verify the degree of agreement between the three national metrology institutes involved in the study. Consistency well within one part per million (ppm) was found. Due to harsh environmental conditions during shipment, the ULCA's transfer accuracy had been limited to about +/-0.4 ppm. Supplemental measurements performed at PTB indicate that further improvements in accuracy are possible. Relative uncertainties of 0.1 ppm are achieved by applying on-site calibration of the ULCA with a suitable cryogenic current comparator.

preprint2014arXiv

Traceable precision pA direct current measurements with the ULCA

A standard method for picoammeter calibrations is the capacitor charging technique, which allows generating traceable currents in the sub-nA range. However, its accuracy is limited by the ac-dc differences of the capacitances involved. The Ultrastable Low-noise Current Amplifier (ULCA) is a novel high-precision amperemeter for direct current measurements in the pA range, developed at PTB. Its amplifier stages, based on resistor networks and op-amps, can be calibrated traceably with a cryogenic current comparator (CCC) system. We compare the results from both independent calibration routes for two different ULCA prototypes. We find agreement between both methods at an uncertainty level below 10 microA/A, limited by the uncertainty of the currents generated with the capacitor charging method. The investigations confirm the superior performance of the new ULCA picoammeter.

preprint2014arXiv

Ultrastable low-noise current amplifier

An ultrastable low-noise current amplifier (ULCA) is presented. The ULCA is a non-cryogenic instrument based on specially designed operational amplifiers and resistor networks. It involves two stages, the first providing a 1000-fold current gain and the second performing a current-to-voltage conversion via an internal 1 MOhm reference resistor or, optionally, an external standard resistor. The ULCA's transfer coefficient is extremely stable versus time, temperature and current amplitude within the full dynamic range of +/-5 nA. A low noise level of 2.4 fA/sqrt(Hz) helps to keep averaging times low at small input currents. A cryogenic current comparator is used to calibrate both input current gain and output transresistance, providing traceability to the quantum Hall effect. Typically, within one day after calibration, the uncertainty contribution from short-term fluctuations of the transresistance is below one part in 10^7. The long-term stability is expected to be better than one part in 10^5 over a year. A high-precision variant is available that shows a substantially improved stability at the expense of a higher noise level of 7.5 fA/sqrt(Hz). The ULCA also allows the traceable generation of small electrical currents or the calibration of high-ohmic resistors.

preprint2012arXiv

Quantum Metrology Triangle Experiments: A Status Review

Quantum Metrology Triangle experiments combine three quantum electrical effects (the Josephson effect, the quantum Hall effect and the single-electron transport effect) used in metrology. These experiments allow important fundamental consistency tests on the validity of commonly assumed relations between fundamental constants of nature and the quantum electrical effects. This paper reviews the history, results and the present status and perspectives of Quantum Metrology Triangle experiments. It also reflects on the possible implications of results for the knowledge on fundamental constants and the quantum electrical effects.