Researcher profile

Dietmar Drung

Dietmar Drung contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2014arXiv

Traceable precision pA direct current measurements with the ULCA

A standard method for picoammeter calibrations is the capacitor charging technique, which allows generating traceable currents in the sub-nA range. However, its accuracy is limited by the ac-dc differences of the capacitances involved. The Ultrastable Low-noise Current Amplifier (ULCA) is a novel high-precision amperemeter for direct current measurements in the pA range, developed at PTB. Its amplifier stages, based on resistor networks and op-amps, can be calibrated traceably with a cryogenic current comparator (CCC) system. We compare the results from both independent calibration routes for two different ULCA prototypes. We find agreement between both methods at an uncertainty level below 10 microA/A, limited by the uncertainty of the currents generated with the capacitor charging method. The investigations confirm the superior performance of the new ULCA picoammeter.

preprint2014arXiv

Ultrastable low-noise current amplifier

An ultrastable low-noise current amplifier (ULCA) is presented. The ULCA is a non-cryogenic instrument based on specially designed operational amplifiers and resistor networks. It involves two stages, the first providing a 1000-fold current gain and the second performing a current-to-voltage conversion via an internal 1 MOhm reference resistor or, optionally, an external standard resistor. The ULCA's transfer coefficient is extremely stable versus time, temperature and current amplitude within the full dynamic range of +/-5 nA. A low noise level of 2.4 fA/sqrt(Hz) helps to keep averaging times low at small input currents. A cryogenic current comparator is used to calibrate both input current gain and output transresistance, providing traceability to the quantum Hall effect. Typically, within one day after calibration, the uncertainty contribution from short-term fluctuations of the transresistance is below one part in 10^7. The long-term stability is expected to be better than one part in 10^5 over a year. A high-precision variant is available that shows a substantially improved stability at the expense of a higher noise level of 7.5 fA/sqrt(Hz). The ULCA also allows the traceable generation of small electrical currents or the calibration of high-ohmic resistors.

preprint2013arXiv

Current Sensing Noise Thermometry: A fast practical solution to low temperature measurement

We describe the design and performance of a series of fast, precise current sensing noise thermometers. The thermometers have been fabricated with a range of resistances from 1.290 $Ω$ down to 0.2 m$\mathrmΩ$. This results in either a thermometer that has been optimised for speed, taking advantage of the improvements in superconducting quantum interference device (SQUID) noise and bandwidth, or a thermometer optimised for ultra-low temperature measurement, minimising the system noise temperature. By using a single temperature calibration point, we show that noise thermometers can be used for accurate measurements over a wide range of temperatures below 4 K. Comparisons with a melting curve thermometer, a calibrated germanium thermometer and a pulsed platinum nuclear magnetic resonance thermometer are presented. For the 1.290 $\mathrmΩ$ resistance we measure a 1 % precision in just 100 ms, and have shown this to be independent of temperature.

preprint2013arXiv

Micro-coil detection of Nuclear Magnetic Resonance for nanofluidic samples

We have developed a novel dc SQUID system with a micro-coil input circuit to act as a local probe of quantum matter and nanosystems. The planar niobium micro-coil pickup loop is located remotely from the SQUID, coupled through a superconducting twisted pair, enabling the sample to be at microkelvin temperatures. A high degree of coupling between the coil and the region of interest of similar dimensions (up to ~ 100 microns) can be achieved. We report nuclear magnetic resonance (NMR) measurements to characterise the sensitivity of these coils to 3He in the gas phase at 4.2 K in a 30 mT magnetic field.

preprint2013arXiv

Study of superfluid $^3$He under nanoscale confinement. A new approach to the investigation of superfluid $^3$He films

We review recent experiments in which superfluid $^3$He has been studied under highly controlled confinement in nanofluidic sample chambers. We discuss the experimental challenges and their resolution. These methods open the way to a systematic investigation of the superfluidity of $^3$He films, and the surface and edge excitations of topological superfluids.