Improved Calibration of Instruments for Small Direct Currents

We report on new calibration methods for picoammeters and low-current sources. The "Ultrastable Low-noise Current Amplifier" (ULCA) was used for the exemplary calibration of commercial state-of-the-art ammeter and current source instruments in the current range between 1 femtoampere and 1 microampere. The uncertainties achieved are compared with results obtained from two other calibration methods for small direct currents. It is shown that using the ULCA as calibrator allows achieving lower uncertainties together with the benefit of easier handling compared to alternative techniques. Also, the ULCA allows performing current meter and source calibrations between 1 femtoampere and 1 microampere with a single method.

preprint2015arXiv

Validation of a quantized-current source with 0.2 ppm uncertainty

We report on high-accuracy measurements of quantized current, sourced by a tunable-barrier single-electron pump at frequencies $f$ up to $1$ GHz. The measurements were performed with a new picoammeter instrument, traceable to the Josephson and quantum Hall effects. Current quantization according to $I=ef$ with $e$ the elementary charge was confirmed at $f=545$ MHz with a total relative uncertainty of 0.2 ppm, improving the state of the art by about a factor of 5. For the first time, the accuracy of a possible future quantum current standard based on single-electron transport was experimentally validated to be better than the best realization of the ampere within the present SI.

preprint2015arXiv

Validation of the ultrastable low-noise current amplifier as travelling standard for small direct currents

An interlaboratory comparison of small-current generation and measurement capability is presented with the ultrastable low-noise current amplifier (ULCA) acting as travelling standard. Various measurements at direct currents between 0.16 nA and 13 nA were performed to verify the degree of agreement between the three national metrology institutes involved in the study. Consistency well within one part per million (ppm) was found. Due to harsh environmental conditions during shipment, the ULCA's transfer accuracy had been limited to about +/-0.4 ppm. Supplemental measurements performed at PTB indicate that further improvements in accuracy are possible. Relative uncertainties of 0.1 ppm are achieved by applying on-site calibration of the ULCA with a suitable cryogenic current comparator.

preprint2014arXiv

Traceable precision generation and measurement of pA direct currents

We present the comparison of results from the generation and the measurement of direct currents in the pA range, performed with traceable state-of-the-art methods at highest accuracy. The currents were generated with the capacitor charging method, and measured with the first prototype of a novel picoammeter developed at PTB. The results confirm the agreement between both methods and the linearity of the new picoammeter at an uncertainty level of few microA/A. Also, they shed light on the ac-dc difference of capacitors, crucial for current generation with the capacitor charging method.

preprint2014arXiv

Traceable precision pA direct current measurements with the ULCA

A standard method for picoammeter calibrations is the capacitor charging technique, which allows generating traceable currents in the sub-nA range. However, its accuracy is limited by the ac-dc differences of the capacitances involved. The Ultrastable Low-noise Current Amplifier (ULCA) is a novel high-precision amperemeter for direct current measurements in the pA range, developed at PTB. Its amplifier stages, based on resistor networks and op-amps, can be calibrated traceably with a cryogenic current comparator (CCC) system. We compare the results from both independent calibration routes for two different ULCA prototypes. We find agreement between both methods at an uncertainty level below 10 microA/A, limited by the uncertainty of the currents generated with the capacitor charging method. The investigations confirm the superior performance of the new ULCA picoammeter.

preprint2014arXiv

Ultrastable low-noise current amplifier

An ultrastable low-noise current amplifier (ULCA) is presented. The ULCA is a non-cryogenic instrument based on specially designed operational amplifiers and resistor networks. It involves two stages, the first providing a 1000-fold current gain and the second performing a current-to-voltage conversion via an internal 1 MOhm reference resistor or, optionally, an external standard resistor. The ULCA's transfer coefficient is extremely stable versus time, temperature and current amplitude within the full dynamic range of +/-5 nA. A low noise level of 2.4 fA/sqrt(Hz) helps to keep averaging times low at small input currents. A cryogenic current comparator is used to calibrate both input current gain and output transresistance, providing traceability to the quantum Hall effect. Typically, within one day after calibration, the uncertainty contribution from short-term fluctuations of the transresistance is below one part in 10^7. The long-term stability is expected to be better than one part in 10^5 over a year. A high-precision variant is available that shows a substantially improved stability at the expense of a higher noise level of 7.5 fA/sqrt(Hz). The ULCA also allows the traceable generation of small electrical currents or the calibration of high-ohmic resistors.

preprint2013arXiv

Current Sensing Noise Thermometry: A fast practical solution to low temperature measurement

We describe the design and performance of a series of fast, precise current sensing noise thermometers. The thermometers have been fabricated with a range of resistances from 1.290 $Ω$ down to 0.2 m$\mathrmΩ$. This results in either a thermometer that has been optimised for speed, taking advantage of the improvements in superconducting quantum interference device (SQUID) noise and bandwidth, or a thermometer optimised for ultra-low temperature measurement, minimising the system noise temperature. By using a single temperature calibration point, we show that noise thermometers can be used for accurate measurements over a wide range of temperatures below 4 K. Comparisons with a melting curve thermometer, a calibrated germanium thermometer and a pulsed platinum nuclear magnetic resonance thermometer are presented. For the 1.290 $\mathrmΩ$ resistance we measure a 1 % precision in just 100 ms, and have shown this to be independent of temperature.

preprint2013arXiv

Micro-coil detection of Nuclear Magnetic Resonance for nanofluidic samples

We have developed a novel dc SQUID system with a micro-coil input circuit to act as a local probe of quantum matter and nanosystems. The planar niobium micro-coil pickup loop is located remotely from the SQUID, coupled through a superconducting twisted pair, enabling the sample to be at microkelvin temperatures. A high degree of coupling between the coil and the region of interest of similar dimensions (up to ~ 100 microns) can be achieved. We report nuclear magnetic resonance (NMR) measurements to characterise the sensitivity of these coils to 3He in the gas phase at 4.2 K in a 30 mT magnetic field.

preprint2013arXiv

Study of superfluid $^3$He under nanoscale confinement. A new approach to the investigation of superfluid $^3$He films

We review recent experiments in which superfluid $^3$He has been studied under highly controlled confinement in nanofluidic sample chambers. We discuss the experimental challenges and their resolution. These methods open the way to a systematic investigation of the superfluidity of $^3$He films, and the surface and edge excitations of topological superfluids.