Researcher profile

Hajime Inaba

Hajime Inaba contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
10works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

10 published item(s)

preprint2022arXiv

Ultra-precise determination of thicknesses and refractive indices of optically thick dispersive materials by dual-comb spectroscopy

Precise measurements of the geometrical thickness of a sample and its refractive index are important for materials science, engineering, and medical diagnosis. Among the possible non-contact evaluation methods, optical interferometric techniques possess the potential of providing superior resolution. However, in the optical frequency region, the ambiguity in the absolute phase-shift makes it difficult to measure these parameters of optically thick dispersive materials with sufficient resolution. Here, we demonstrate that dual frequency-comb spectroscopy can be used to precisely determine the absolute sample-induced phase-shift by analyzing the data smoothness. This method enables simultaneous determination of the geometrical thickness and the refractive index of a planar sample with a precision of five and a half digits and an ultra-wide dynamic range. The thickness and the refractive index at 193.414 THz of a silicon wafer determined by this method are 0.52047(3) mm and 3.4756(3), respectively, without any prior knowledge of the refractive index.

preprint2016arXiv

Absolute frequency measurements and hyperfine structures of the molecular iodine transitions at 578 nm

We report absolute frequency measurements of 81 hyperfine components of the rovibrational transitions of molecular iodine at 578 nm using the second harmonic generation of an 1156-nm external-cavity diode laser and a fiber-based optical frequency comb. The relative uncertainties of the measured absolute frequencies are typically $1.4\times10^{-11}$. Accurate hyperfine constants of four rovibrational transitions are obtained by fitting the measured hyperfine splittings to a four-term effective Hamiltonian including the electric quadrupole, spin-rotation, tensor spin-spin, and scalar spin-spin interactions. The observed transitions can be good frequency references at 578 nm, and are especially useful for research using atomic ytterbium since the transitions are close to the $^{1}S_{0}-^{3}P_{0}$ clock transition of ytterbium.

preprint2015arXiv

A compact iodine-laser operating at 531 nm with stability at the 10$^{-12}$ level and using a coin-sized laser module

We demonstrate a compact iodine-stabilized laser operating at 531 nm using a coin-sized light source consisting of a 1062-nm distributed-feedback diode laser and a frequency-doubling element. A hyperfine transition of molecular iodine is observed using the light source with saturated absorption spectroscopy. The light source is frequency stabilized to the observed iodine transition and achieves frequency stability at the 10$^{-12}$ level. The absolute frequency of the compact laser stabilized to the $a_{1}$ hyperfine component of the $R(36)32-0$ transition is determined as $564\,074\,632\,419(8)$ kHz with a relative uncertainty of $1.4\times10^{-11}$. The iodine-stabilized laser can be used for various applications including interferometric measurements.

preprint2015arXiv

Real-time absolute frequency measurement of continuous-wave terahertz wave based on dual terahertz combs of photocarriers with different frequency spacings

Real-time measurement of the absolute frequency of continuous-wave terahertz (CW-THz) waves is required for characterization and frequency calibration of practical CW-THz sources. We proposed a method for real-time monitoring of the absolute frequency of CW-THz waves involving temporally parallel, i.e., simultaneous, measurement of two pairs of beat frequencies and laser repetition frequencies based on dual THz combs of photocarriers (PC-THz combs) with different frequency spacings. To demonstrate the method, THz-comb-referenced spectrum analyzers were constructed with a dual configuration based on dual femtosecond lasers. Regardless of the presence or absence of frequency control in the PC-THz combs, a frequency precision of 10-11 was achieved at a measurement rate of 100 Hz. Furthermore, large fluctuation of the CW-THz frequencies, crossing several modes of the PC-THz combs, was correctly monitored in real time. The proposed method will be a powerful tool for the research and development of practical CW-THz sources, and other applications.

preprint2015arXiv

Ultra-broadband dual-comb spectroscopy across 1.0-1.9 μm

We have carried out dual-comb spectroscopy and observed in a simultaneous acquisition a 140-THz-wide spectrum from 1.0 to 1.9 μm using two fiber-based frequency combs phase-locked to each other. This ultra-broad wavelength bandwidth is realized by setting the difference between the repetition rates of the two combs to 7.6 Hz using the sub-Hz-linewidth fiber combs. The recorded spectrum contains five vibration-rotation bands of C${_2}$H${_2}$, CH${_4}$, and H${_2}$O at different wavelengths across the whole spectrum. The determined transition frequencies of C${_2}$H${_2}$ agree with those from the previous sub-Doppler resolution measurement of individual lines using CW lasers within 2 MHz.

preprint2014arXiv

Adaptive sampling dual terahertz comb spectroscopy using free-running dual femtosecond lasers

Dual terahertz (THz) comb spectroscopy is a promising methods for high accuracy, high resolution, and broadband THz spectroscopy because the mode-resolved THz comb spectrum possesses both characteristics of broadband THz radiation and narrow-linewidth continuous-wave THz radiation and all frequency mode of THz comb can be phase-locked to a microwave frequency standard. However, requirement of stabilized dual femtosecond lasers has often hindered wide use of this method. In this article, we demonstrated the adaptive sampling, dual THz comb spectroscopy, enabling use of free-running dual femtosecond lasers. To correct the non-linearity of time and frequency scale caused by the laser timing jitter, an adaptive sampling clock is generated by dual THz-comb-referenced spectrum analysers and is used for a timing signal in a data acquisition board. The demonstrated results did not only indicate the implementation of dual THz comb spectroscopy with free-running dual lasers but also implied the superiority of its spectroscopic performance over the dual THz comb spectroscopy with stabilized dual lasers.

preprint2014arXiv

Frequency ratio measurement of 171Yb and 87Sr optical lattice clocks

The frequency ratio of the 1S0(F=1/2)-3P0(F=1/2) clock transition in 171Yb and the 1S0(F=9/2)-3P0(F=9/2) clock transition in 87Sr is measured by an optical-optical direct frequency link between two optical lattice clocks. We determined the ratio (ν_{Yb}/ν_{Sr}) to be 1.207 507 039 343 340 4(18) with a fractional uncertainty of 1.5x10^{-15}. The measurement uncertainty of the frequency ratio is smaller than that obtained from absolute frequency measurements using the International Atomic Time (TAI) link. The measured ratio agrees well with that derived from the absolute frequency measurement results obtained at NIST and JILA, Boulder, CO using their Cs-fountain clock. Our measurement enables the first international comparison of the frequency ratios of optical clocks, and we obtained a good agreement between the two measured ratios with an uncertainty smaller than the TAI link. The measured frequency ratio will be reported to the International Committee for Weights and Measures for a discussion related to the redefinition of the second.

preprint2014arXiv

Spectroscopy and frequency measurement of the $^{87}$Sr clock transition by laser linewidth transfer using an optical frequency comb

We perform spectroscopic observations of the 698-nm clock transition in $^{87}$Sr confined in an optical lattice using a laser linewidth transfer technique. A narrow-linewidth laser interrogating the clock transition is prepared by transferring the linewidth of a master laser (1064 nm) to that of a slave laser (698 nm) with a high-speed controllable fiber-based frequency comb. The Fourier-limited spectrum is observed for an 80-ms interrogating pulse. We determine that the absolute frequency of the 5s$^{2}$ $^{1}$S$_{0}$ - 5s5p $^{3}$P$_{0}$ clock transition in $^{87}$Sr is 429 228 004 229 872.0 (1.6) Hz referenced to the SI second.

preprint2013arXiv

Gapless dual-comb spectroscopy in terahertz region

We demonstrated combination of gapless terahertz (THz) comb with dual-comb spectroscopy, namely gapless dual-THz-comb spectroscopy, to achieve the spectral resolution equal to width of the THz comb tooth. The gapless THz comb was realized by interpolating frequency gaps between the comb teeth with sweeping of a laser mode-locked frequency. The demonstration of low-pressure gas spectroscopy with gapless dual-THz-comb spectroscopy clearly indicated that the spectral resolution was decreased down to 2.5-MHz width of the comb tooth and the spectral accuracy was enhanced to 10-6 within the spectral range of 1THz. The proposed method will be a powerful tool to simultaneously achieve high resolution, high accuracy, and broad spectral coverage in THz spectroscopy.

preprint2010arXiv

Fiber-comb-stabilized light source at 556 nm for magneto-optical trapping of ytterbium

A frequency-stabilized light source emitting at 556 nm is realized by frequency-doubling a 1112-nm laser, which is phase-locked to a fiber-based optical frequency comb. The 1112-nm laser is either an ytterbium (Yb)-doped distributed feedback fiber laser or a master-slave laser system that uses an external cavity diode laser as a master laser. We have achieved the continuous frequency stabilization of the light source over a five-day period. With the light source, we have completed the second-stage magneto-optical trapping (MOT) of Yb atoms using the 1S0 - 3P1 intercombination transition. The temperature of the ultracold atoms in the MOT was 40 uK when measured using the time-of-flight method, and this is sufficient for loading the atoms into an optical lattice. The fiber-based frequency comb is shown to be a useful tool for controlling the laser frequency in cold-atom experiments.