Source author record

H. Wollnik

H. Wollnik appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

A new study of the $N=32$ and $N=34$ shell gap for Ti and V by the first high-precision MRTOF mass measurements at BigRIPS-SLOWRI

The atomic masses of $^{55}$Sc, $^{56,58}$Ti, and $^{56-59}$V have been determined using the high-precision multi-reflection time-of-flight technique. The radioisotopes have been produced at RIKEN's RIBF facility and delivered to the novel designed gas cell and multi-reflection system (ZD MRTOF), which has been recently commissioned downstream of the ZeroDegree spectrometer following the BigRIPS separator. For $^{56,58}$Ti and $^{56-59}$V the mass uncertainties have been reduced down to the order of $10\,\mathrm{keV}$, shedding new light on the $N=34$ shell effect in Ti and V isotopes by the first high-precision mass measurements of the critical species $^{58}$Ti and $^{59}$V. With the new precision achieved, we reveal the non-existence of the $N=34$ empirical two-neutron shell gaps for Ti and V, and the enhanced energy gap above the occupied $νp_{3/2}$ orbit is identified as a feature unique to Ca. We perform new Monte Carlo shell model calculations including the $νd_{5/2}$ and $νg_{9/2}$ orbits and compare the results with conventional shell model calculations, which exclude the $νg_{9/2}$ and the $νd_{5/2}$ orbits. The comparison indicates that the shell gap reduction in Ti is related to a partial occupation of the higher orbitals for the outer two valence neutrons at $N=34$.

preprint2019arXiv

Development of an "$α$-ToF" detector for correlated measurement of atomic masses and decay properties

We have developed a novel detector, referred to as an "$α$-ToF detector", for correlated measurements of atomic masses and decay properties of low-yield, short-lived radioactive isotopes using a multi-reflection time-of-flight mass spectrograph. By correlating measured time-of-flight signals with decay events, it will be possible to suppress background events and obtain accurate, high-precision mass values even in cases of very low event rates. An offline test of the $α$-ToF detector has shown that the time-of-flight detection efficiency for 5.48~MeV $α$-rays is more than 90\% and yields a time resolution of 251.5(68)~ps and an energy resolution of 141.1(9)~keV. Using a two-dimensional spectrum of the correlated $α$-ray energy and time-of-flight, the $α$-rays from mixed $α$ sources could be fairly well resolved.

preprint2013arXiv

A novel ion cooling trap for multi-reflection time-of-flight mass spectrograph

A radiofrequency quadrupole ion trap system for use with a multi-reflection time-of-flight mass spectrograph (MRTOF) for short-lived nuclei has been developed. The trap system consists of two different parts, an asymmetric taper trap and a flat trap. The ions are cooled to a sufficient small bunch for precise mass measurement with MRTOF in only 2 ms cooling time in the flat trap, then orthogonally ejected to the MRTOF for mass analysis. A trapping efficiency of ~27% for 23Na+ and ~5.1% for 7Li+ has been achieved.

preprint2013arXiv

Single-reference high-precision mass measurement with a multi-reflection time-of-flight mass spectrograph

A multi-reflection time-of-flight mass spectrograph, competitive with Penning trap mass spectrometers, has been built at RIKEN. We have performed a first online mass measurement, using 8Li+ (T1/2 = 838 ms). A new analysis method has been realized, with which, using only 12C+ references, the mass excess of 8Li was accurately determined to be 20947.6(15)(34) keV (dm/m = 6.6 x 10-7). The speed, precision and accuracy of this first online measurement exemplifies the potential for using this new type of mass spectrograph for precision measurements of short-lived nuclei.

preprint2012arXiv

An rf-carpet electrospray ion source to provide isobaric mass calibrants for trans-uranium elements

For trans-uranium elements, stable atomic isobars do not exist. In order to provide isobaric reference ions for the mass measurement of trans-uranium elements, an electrospray ion source (ESI) was combined with an rf-carpet to collect molecular ions efficiently. The rf-carpet allows for simplification of the pumping system to transport ions from the ESI to a precision mass analyzer. Molecular ions appropriate for isobaric references of trans-uranium elements were extracted from the rf-carpet and analyzed by a multi-reflection time-of-flight mass spectrograph (MRTOF-MS) with a resolving power of $\rm{R_m} \gtrsim100,000$.