Source author record

H. S. Margolis

H. S. Margolis appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

7works
8topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2022arXiv

Measuring the stability of fundamental constants with a network of clocks

The detection of variations of fundamental constants of the Standard Model would provide us with compelling evidence of new physics, and could lift the veil on the nature of dark matter and dark energy. In this work, we discuss how a network of atomic and molecular clocks can be used to look for such variations with unprecedented sensitivity over a wide range of time scales. This is precisely the goal of the recently launched QSNET project: A network of clocks for measuring the stability of fundamental constants. QSNET will include state-of-the-art atomic clocks, but will also develop next-generation molecular and highly charged ion clocks with enhanced sensitivity to variations of fundamental constants. We describe the technological and scientific aims of QSNET and evaluate its expected performance. We show that in the range of parameters probed by QSNET, either we will discover new physics, or we will impose new constraints on violations of fundamental symmetries and a range of theories beyond the Standard Model, including dark matter and dark energy models.

preprint2019arXiv

Direct comparisons of European primary and secondary frequency standards via satellite techniques

We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taking into account correlations and gaps in the measurement data, combined overall uncertainties in the range of $1.8 \times 10^{-16}$ to $3.5 \times 10^{-16}$ for the optical clock comparisons were found. The comparison of the fountain clocks yields results with a maximum relative frequency difference of $6.9 \times 10^{-16}$, and combined overall uncertainties in the range of $4.8 \times 10^{-16}$ to $7.7 \times 10^{-16}$.

preprint2019arXiv

Search for transient variations of the fine structure constant and dark matter using fiber-linked optical atomic clocks

We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation in alpha to <5*10^-17 for transients of duration 10^3 s. This analysis also presents a possibility to search for dark matter, the mysterious substance hypothesised to explain galaxy dynamics and other astrophysical phenomena that is thought to dominate the matter density of the universe. At the current sensitivity level, we find no evidence for dark matter in the form of topological defects (or, more generally, any macroscopic objects), and we thus place constraints on certain potential couplings between the dark matter and standard model particles, substantially improving upon the existing constraints, particularly for large (>~10^4 km) objects.

preprint2015arXiv

Frequency comparison of ${}^{171}$Yb${}^+$ ion optical clocks at PTB and NPL via GPS PPP

We used Precise Point Positioning, a well-established GPS carrier-phase frequency transfer method to perform a direct remote comparison of two optical frequency standards based on single laser-cooled $^{171}$Yb$^+$ ions operated at NPL, UK and PTB, Germany. At both institutes an active hydrogen maser serves as a flywheel oscillator; it is connected to a GPS receiver as an external frequency reference and compared simultaneously to a realization of the unperturbed frequency of the ${{}^2S_{1/2}(F=0)-{}^2D_{3/2}(F=2)}$ electric quadrupole transition in ${}^{171}$Yb${}^+$ via an optical femtosecond frequency comb. To profit from long coherent GPS link measurements we extrapolate over the various data gaps in the optical clock to maser comparisons which introduces maser noise to the frequency comparison but improves the uncertainty from the GPS link. We determined the total statistical uncertainty consisting of the GPS link uncertainty and the extrapolation uncertainties for several extrapolation schemes. Using the extrapolation scheme with the smallest combined uncertainty, we find a fractional frequency difference $y(\mathrm{PTB})-y(\mathrm{NPL})$ of $-1.3(1.2)\times 10^{-15}$ for a total measurement time of 67 h. This result is consistent with an agreement of both optical clocks and with recent absolute frequency measurements against caesium fountain clocks.

preprint2015arXiv

Least-squares analysis of clock frequency comparison data to deduce optimized frequency and frequency ratio values

A method is presented for analysing over-determined sets of clock frequency comparison data involving standards based on a number of different reference transitions. This least-squares adjustment procedure, which is based on the method used by CODATA to derive a self-consistent set of values for the fundamental physical constants, can be used to derive optimized values for the frequency ratios of all possible pairs of reference transitions. It is demonstrated to reproduce the frequency values recommended by the International Committee for Weights and Measures, when using the same input data used to derive those values. The effects of including more recently published data in the evaluation is discussed and the importance of accounting for correlations between the input data is emphasised.

preprint2014arXiv

Evaluating the performance of the NPL femtosecond frequency combs: Agreement at the $10^{-21}$ level

Results are presented from a series of comparisons between two independent femtosecond frequency comb systems at NPL, which were carried out in order to assess their systematic uncertainty. Simultaneous measurements with the two systems demonstrate agreement at the level of 5 x $10^{-18}$ when measuring an optical frequency against a common microwave reference. When simultaneously measuring the ratio of two optical frequencies, agreement at the 3 x $10^{-21}$ level is observed. The results represent the highest reported level of agreement to date between Ti:sapphire and Er-doped femtosecond combs. The limitations of the combs when operating in these two different manners are discussed, including traceability to the SI second, which can be achieved with an uncertainty below 1 x $10^{-16}$. The technical details presented underpin recent absolute frequency measurements of the $^{88}$Sr$^+$ and $^{171}$Yb$^+$ optical clock transitions at NPL, as well as a frequency ratio measurement between the two optical clock transitions in $^{171}$Yb$^+$.

preprint2014arXiv

Frequency ratio of two optical clock transitions in $^{171}$Yb$^+$ and constraints on the time-variation of fundamental constants

Singly-ionized ytterbium, with ultra-narrow optical clock transitions at 467 nm and 436 nm, is a convenient system for the realization of optical atomic clocks and tests of present-day variation of fundamental constants. We present the first direct measurement of the frequency ratio of these two clock transitions, without reference to a cesium primary standard, and using the same single ion of 171Yb+. The absolute frequencies of both transitions are also presented, each with a relative standard uncertainty of $6\times 10^{-16}$. Combining our results with those from other experiments, we report a three-fold improvement in the constraint on the time-variation of the proton-to-electron mass ratio, $\dotμ/μ = 0.2(1.1)\times 10^{-16}$ year$^{-1}$, along with an improved constraint on time-variation of the fine structure constant, $\dotα/α = -0.7(2.1)\times 10^{-17}$ year$^{-1}$.