Source author record

Gustavo Cancelo

Gustavo Cancelo appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

17works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

17 published item(s)

preprint2026arXiv

PhotonIDs: ML-Powered Photon Identification System for Dark Count Elimination

Reliable single photon detection is the foundation for practical quantum communication and networking. However, today's superconducting nanowire single photon detector(SNSPD) inherently fails to distinguish between genuine photon events and dark counts, leading to degraded fidelity in long-distance quantum communication. In this work, we introduce PhotonIDs, a machine learning-powered photon identification system that is the first end-to-end solution for real-time discrimination between photons and dark count based on full SNSPD readout signal waveform analysis. PhotonIDs ~demonstrates: 1) an FPGA-based high-speed data acquisition platform that selectively captures the full waveform of signal only while filtering out the background data in real time; 2) an efficient signal preprocessing pipeline, and a novel pseudo-position metric that is derived from the physical temporal-spatial features of each detected event; 3) a hybrid machine learning model with near 98% accuracy achieved on photon/dark count classification. Additionally, proposed PhotonIDs ~ is evaluated on the dark count elimination performance with two real-world case studies: (1) 20 km quantum link, and (2) Erbium ion-based photon emission system. Our result demonstrates that PhotonIDs ~could improve more than 31.2 times of signal-noise-ratio~(SNR) on dark count elimination. PhotonIDs ~ marks a step forward in noise-resilient quantum communication infrastructure.

preprint2026arXiv

SQuaD: Smart Quantum Detection for Photon Recognition and Dark Count Elimination

Quantum detectors of single photons are an essential component for quantum information processing across computing, communication and networking. Today's quantum detection system, which consists of single photon detectors, timing electronics, control and data processing software, is primarily used for counting the number of single photon detection events. However, it is largely incapable of extracting other rich physical characteristics of the detected photons, such as their wavelengths, polarization states, photon numbers, or temporal waveforms. This work, for the first time, demonstrates a smart quantum detection system, SQuaD, which integrates a field programmable gate array (FPGA) with a neural network model, and is designed to recognize the features of photons and to eliminate detector dark-count. The SQuaD is a fully integrated quantum system with high timing-resolution data acquisition, onboard multi-scale data analysis, intelligent feature recognition and extraction, and feedback-driven system control. Our \name experimentally demonstrates 1) reliable photon counting on par with the state-of-the art commercial systems; 2) high-throughput data processing for each individual detection events; 3) efficient dark count recognition and elimination; 4) up to 100\% accurate feature recognition of photon wavelength and polarization. Additionally, we deploy the SQuaD to an atomic (erbium ion) photon emitter source to realize noise-free control and readout of a spin qubit in the telecom band, enabling critical advances in quantum networks and distributed quantum information processing.

preprint2022arXiv

Quantum computing hardware for HEP algorithms and sensing

Quantum information science harnesses the principles of quantum mechanics to realize computational algorithms with complexities vastly intractable by current computer platforms. Typical applications range from quantum chemistry to optimization problems and also include simulations for high energy physics. The recent maturing of quantum hardware has triggered preliminary explorations by several institutions (including Fermilab) of quantum hardware capable of demonstrating quantum advantage in multiple domains, from quantum computing to communications, to sensing. The Superconducting Quantum Materials and Systems (SQMS) Center, led by Fermilab, is dedicated to providing breakthroughs in quantum computing and sensing, mediating quantum engineering and HEP based material science. The main goal of the Center is to deploy quantum systems with superior performance tailored to the algorithms used in high energy physics. In this Snowmass paper, we discuss the two most promising superconducting quantum architectures for HEP algorithms, i.e. three-level systems (qutrits) supported by transmon devices coupled to planar devices and multi-level systems (qudits with arbitrary N energy levels) supported by superconducting 3D cavities. For each architecture, we demonstrate exemplary HEP algorithms and identify the current challenges, ongoing work and future opportunities. Furthermore, we discuss the prospects and complexities of interconnecting the different architectures and individual computational nodes. Finally, we review several different strategies of error protection and correction and discuss their potential to improve the performance of the two architectures. This whitepaper seeks to reach out to the HEP community and drive progress in both HEP research and QIS hardware.

preprint2022arXiv

Search for coherent elastic neutrino-nucleus scattering at a nuclear reactor with CONNIE 2019 data

The Coherent Neutrino-Nucleus Interaction Experiment (CONNIE) is taking data at the Angra 2 nuclear reactor with the aim of detecting the coherent elastic scattering of reactor antineutrinos with silicon nuclei using charge-coupled devices (CCDs). In 2019 the experiment operated with a hardware binning applied to the readout stage, leading to lower levels of readout noise and improving the detection threshold down to 50 eV. The results of the analysis of 2019 data are reported here, corresponding to the detector array of 8 CCDs with a fiducial mass of 36.2 g and a total exposure of 2.2 kg-days. The difference between the reactor-on and reactor-off spectra shows no excess at low energies and yields upper limits at 95% confidence level for the neutrino interaction rates. In the lowest-energy range, 50-180 eV, the expected limit stands at 34 (39) times the standard model prediction, while the observed limit is 66 (75) times the standard model prediction with Sarkis (Chavarria) quenching factors.

preprint2022arXiv

SENSEI: Characterization of Single-Electron Events Using a Skipper-CCD

We use a science-grade Skipper Charge Coupled Device (Skipper-CCD) operating in a low-radiation background environment to develop a semi-empirical model that characterizes the origin of single-electron events in CCDs. We identify, separate, and quantify three independent contributions to the single-electron events, which were previously bundled together and classified as "dark counts": dark current, amplifier light, and spurious charge. We measure a dark current, which depends on exposure, of (5.89+-0.77)x10^-4 e-/pix/day, and an unprecedentedly low spurious charge contribution of (1.52+-0.07)x10^-4 e-/pix, which is exposure-independent. In addition, we provide a technique to study events produced by light emitted from the amplifier, which allows the detector's operation to be optimized to minimize this effect to a level below the dark-current contribution. Our accurate characterization of the single-electron events allows one to greatly extend the sensitivity of experiments searching for dark matter or coherent neutrino scattering. Moreover, an accurate understanding of the origin of single-electron events is critical to further progress in ongoing R&D efforts of Skipper and conventional CCDs.

preprint2022arXiv

The Oscura Experiment

The Oscura experiment will lead the search for low-mass dark matter particles using a very large array of novel silicon Charge Coupled Devices (CCDs) with a threshold of two electrons and with a total exposure of 30 kg-yr. The R&D effort, which began in FY20, is currently entering the design phase with the goal of being ready to start construction in late 2024. Oscura will have unprecedented sensitivity to sub-GeV dark matter particles that interact with electrons, probing dark matter-electron scattering for masses down to 500 keV and dark matter being absorbed by electrons for masses down to 1 eV. The Oscura R&D effort has made some significant progress on the main technical challenges of the experiment, of which the most significant are engaging new foundries for the fabrication of the CCD sensors, developing a cold readout solution, and understanding the experimental backgrounds.

preprint2020arXiv

A measurement of absolute efficiency of the ARAPUCA photon detector in Liquid Argon

In the Fall of 2017, two photon detector designs for the Deep Underground Neutrino Experiment (DUNE) Far Detector were installed and tested in the TallBo liquid argon (LAr) cryostat at the Proton Assembly (PAB) facility, Fermilab. The designs include two light bars developed at Indiana University and a photon detector based on the ARAPUCA light trap engineered by Colorado State University and Fermilab. The performance of these devices is determined by analyzing 8 weeks of cosmic ray data. The current paper focuses solely on the ARAPUCA device as the performance of the light bars will be reported separately. The paper briefly describes the ARAPUCA concept, the TallBo setup, and focuses on data analysis and results.

preprint2020arXiv

Interplay between phonon downconversion efficiency, density of states at Fermi energy, and intrinsic energy resolution for microwave kinectic inductance detectors

Microwave Kinetic Inductance detectors (MKIDs) have been recognized as a powerful new tool for single photon detection. These highly multiplexed superconducting devices give timing and energy measurement for every detected photon. However, the full potential of MKID single photon spectroscopy has not been reached , the achieved energy resolution is lower than expected from first principles. Here, we study the efficiency in the phonon downconversion process following the absorption of energetic photons in MKIDs. Assuming previously published material properties, we measure an average downconversion efficiency for three TiN resonators is $η$=0.14. We discuss how this efficiency can impact the intrinsic energy resolution of MKID, and how any uncertainty in the unknown density of electron states at the Fermi energy directly affects the efficiency estimations.

preprint2020arXiv

Low Threshold Acquisition controller for Skipper CCDs

The development of the Skipper Charge Coupled Devices (Skipper-CCDs) has been a major technological breakthrough for sensing very weak ionizing particles. The sensor allows to reach the ultimate sensitivity of silicon material as a charge signal sensor by unambiguous determination of the charge signal collected by each cell or pixel, even for single electron-hole pair ionization. Extensive use of the technology was limited by the lack of specific equipment to operate the sensor at the ultimate performance. In this work a simple, single-board Skipper-CCD controller is presented, aimed for the operation of the detector in high sensitivity scientific applications. The article describes the main components and functionality of the Low Threshold Acquisition (LTA) together with experimental results when connected to a Skipper-CCD sensor. Measurements show unprecedented deep sub-electron noise of 0.039 e$^-_{rms}$/pix for 5000 pixel measurements.

preprint2020arXiv

Search for light mediators in the low-energy data of the CONNIE reactor neutrino experiment

The CONNIE experiment is located at a distance of 30 m from the core of a commercial nuclear reactor, and has collected a 3.7 kg-day exposure using a CCD detector array sensitive to an $\sim$1 keV threshold for the study of coherent neutrino-nucleus elastic scattering. Here we demonstrate the potential of this low-energy neutrino experiment as a probe for physics Beyond the Standard Model, by using the recently published results to constrain two simplified extensions of the Standard Model with light mediators. We compare the new limits with those obtained for the same models using neutrinos from the Spallation Neutron Source. Our new constraints represent the best limits for these simplified models among the experiments searching for CE$ν$NS for a light vector mediator with mass $M_{Z^{\prime}}<$ 10 MeV, and for a light scalar mediator with mass $M_ϕ<$ 30 MeV. These results constitute the first use of the CONNIE data as a probe for physics Beyond the Standard Model.

preprint2016arXiv

Using the Automata Processor for Fast Pattern Recognition in High Energy Physics Experiments - A Proof of Concept

We explore the Micron Automata Processor (AP) as a suitable commodity technology that can address the growing computational needs of pattern recognition in High Energy Physics (HEP) experiments. A toy detector model is developed for which an electron track confirmation trigger based on the Micron AP serves as a test case. Although primarily meant for high speed text-based searches, we demonstrate a proof of concept for the use of the Micron AP in a HEP trigger application.

preprint2014arXiv

Charge Coupled Devices for detection of coherent neutrino-nucleus scattering

This article details the potential for using Charge Coupled Devices (CCD) to detect low-energy neutrinos through their coherent scattering with nuclei. The detection of neutrinos through this standard model process has not been accessible because of the small energy deposited in such interactions with the detector nuclei. Typical particle detectors have thresholds of a few keV, and most of the energy deposition expected from coherent scattering is well below this level. The devices we discuss can be operated at a threshold of approximately 30 eV, making them ideal for observing this signal. For example, the number of coherent scattering events expected on a 52 gram CCD array located next to a power nuclear reactor is estimated as approximately 626 events/year. The results of our study show that detection at a confidence level of 99% can be reached within three months for this kind of detector array.

preprint2014arXiv

DAMIC at SNOLAB

We introduce the fully-depleted charge-coupled device (CCD) as a particle detector. We demonstrate its low energy threshold operation, capable of detecting ionizing energy depositions in a single pixel down to 50 eVee. We present results of energy calibrations from 0.3 keVee to 60 keVee, showing that the CCD is a fully active detector with uniform energy response throughout the silicon target, good resolution (Fano ~0.16), and remarkable linear response to electron energy depositions. We show the capability of the CCD to localize the depth of particle interactions within the silicon target. We discuss the mode of operation and unique imaging capabilities of the CCD, and how they may be exploited to characterize and suppress backgrounds. We present the first results from the deployment of 250 um thick CCDs in SNOLAB, a prototype for the upcoming DAMIC100. DAMIC100 will have a target mass of 0.1 kg and should be able to directly test the CDMS-Si signal within a year of operation.

preprint2014arXiv

Development of a novel neutron detection technique by using a boron layer coating a Charge Coupled Device

This article describes the design features and the first test measurements obtained during the installation of a novel high resolution 2D neutron detection technique. The technique proposed in this work consists of a boron layer (enriched in ${^{10}}$B) placed on a scientific Charge Coupled Device (CCD). After the nuclear reaction ${^{10}}$B(n,$α$)${^{7}}$Li, the CCD detects the emitted charge particles thus obtaining information on the neutron absorption position. The above mentioned ionizing particles, with energies in the range 0.5-5.5 MeV, produce a plasma effect in the CCD which is recorded as a circular spot. This characteristic circular shape, as well as the relationship observed between the spot diameter and the charge collected, is used for the event recognition, allowing the discrimination of undesirable gamma events. We present the first results recently obtained with this technique, which has the potential to perform neutron tomography investigations with a spatial resolution better than that previously achieved. Numerical simulations indicate that the spatial resolution of this technique will be about 15 $μ$m, and the intrinsic detection efficiency for thermal neutrons will be about 3 %. We compare the proposed technique with other neutron detection techniques and analyze its advantages and disadvantages.

preprint2013arXiv

DAMIC: a novel dark matter experiment

DAMIC (Dark Matter in CCDs) is a novel dark matter experiment that has unique sensitivity to dark matter particles with masses below 10 GeV. Due to its low electronic readout noise (R.M.S. ~3 e-) this instrument is able to reach a detection threshold below 0.5 keV nuclear recoil energy, making the search for dark matter particles with low masses possible. We report on early results and experience gained from a detector that has been running at SNOLAB from Dec 2012. We also discuss the measured and expected backgrounds and present the plan for future detectors to be installed in 2014.

preprint2011arXiv

Achieving sub-electron readout noise in Skipper CCDs

The readout noise for Charge-Coupled Devices (CCDs) has been the main limitation when using these detectors for measuring small amplitude signals. A readout system for a new scientific, low noise CCD is presented in this paper. The Skipper CCD architecture, and its advantages for low noise applications are discussed. A technique for obtaining sub-electron readout noise levels is presented, and its noise and signal characteristics are derived. We demonstrate a very low readout noise of $0.2e^{-}$ RMS. Also, we show the results using the detector in a low-energy X-ray detection experiment.

preprint2011arXiv

Deep sub electron noise readout in CCD systems using digital filtering techniques

Scientific CCDs designed in thick high resistivity silicon (Si) are excellent detectors for astronomy, high energy and nuclear physics, and instrumentation. Many applications can benefit from CCDs ultra low noise readout systems. The present work shows how sub electron noise CCD images can be achieved using digital signal processing techniques. These techniques allow readout bandwidths of up to 10 K pixels per second and keep the full CCD spatial resolution and signal dynamic range.