Source author record

Juan Estrada

Juan Estrada appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

20works
9topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

20 published item(s)

preprint2022arXiv

Photon counting from the vacuum ultraviolet to the short wavelength infrared using semiconductor and superconducting technologies

In the last decade, several photon counting technologies have been developed opening a new window for experiments in the low photon number regime. Several ongoing and future projects in HEP benefit from these developments, which will also have a large impact outside HEP. During the next decade there is a clear technological opportunity to fully develop these sensors and produce a large impact in HEP. In this white paper we discuss the need for photon counting technologies in future projects, and present some technological opportunities to address those needs.

preprint2022arXiv

Search for coherent elastic neutrino-nucleus scattering at a nuclear reactor with CONNIE 2019 data

The Coherent Neutrino-Nucleus Interaction Experiment (CONNIE) is taking data at the Angra 2 nuclear reactor with the aim of detecting the coherent elastic scattering of reactor antineutrinos with silicon nuclei using charge-coupled devices (CCDs). In 2019 the experiment operated with a hardware binning applied to the readout stage, leading to lower levels of readout noise and improving the detection threshold down to 50 eV. The results of the analysis of 2019 data are reported here, corresponding to the detector array of 8 CCDs with a fiducial mass of 36.2 g and a total exposure of 2.2 kg-days. The difference between the reactor-on and reactor-off spectra shows no excess at low energies and yields upper limits at 95% confidence level for the neutrino interaction rates. In the lowest-energy range, 50-180 eV, the expected limit stands at 34 (39) times the standard model prediction, while the observed limit is 66 (75) times the standard model prediction with Sarkis (Chavarria) quenching factors.

preprint2022arXiv

SENSEI: Characterization of Single-Electron Events Using a Skipper-CCD

We use a science-grade Skipper Charge Coupled Device (Skipper-CCD) operating in a low-radiation background environment to develop a semi-empirical model that characterizes the origin of single-electron events in CCDs. We identify, separate, and quantify three independent contributions to the single-electron events, which were previously bundled together and classified as "dark counts": dark current, amplifier light, and spurious charge. We measure a dark current, which depends on exposure, of (5.89+-0.77)x10^-4 e-/pix/day, and an unprecedentedly low spurious charge contribution of (1.52+-0.07)x10^-4 e-/pix, which is exposure-independent. In addition, we provide a technique to study events produced by light emitted from the amplifier, which allows the detector's operation to be optimized to minimize this effect to a level below the dark-current contribution. Our accurate characterization of the single-electron events allows one to greatly extend the sensitivity of experiments searching for dark matter or coherent neutrino scattering. Moreover, an accurate understanding of the origin of single-electron events is critical to further progress in ongoing R&D efforts of Skipper and conventional CCDs.

preprint2022arXiv

The Oscura Experiment

The Oscura experiment will lead the search for low-mass dark matter particles using a very large array of novel silicon Charge Coupled Devices (CCDs) with a threshold of two electrons and with a total exposure of 30 kg-yr. The R&D effort, which began in FY20, is currently entering the design phase with the goal of being ready to start construction in late 2024. Oscura will have unprecedented sensitivity to sub-GeV dark matter particles that interact with electrons, probing dark matter-electron scattering for masses down to 500 keV and dark matter being absorbed by electrons for masses down to 1 eV. The Oscura R&D effort has made some significant progress on the main technical challenges of the experiment, of which the most significant are engaging new foundries for the fabrication of the CCD sensors, developing a cold readout solution, and understanding the experimental backgrounds.

preprint2020arXiv

Dark Energy Survey Year 1 Results: Cosmological Constraints from Cluster Abundances and Weak Lensing

We perform a joint analysis of the counts and weak lensing signal of redMaPPer clusters selected from the Dark Energy Survey (DES) Year 1 dataset. Our analysis uses the same shear and source photometric redshifts estimates as were used in the DES combined probes analysis. Our analysis results in surprisingly low values for $S_8 =σ_8(Ω_{\rm m}/0.3)^{0.5}= 0.65\pm 0.04$, driven by a low matter density parameter, $Ω_{\rm m}=0.179^{+0.031}_{-0.038}$, with $σ_8-Ω_{\rm m}$ posteriors in $2.4σ$ tension with the DES Y1 3x2pt results, and in $5.6σ$ with the Planck CMB analysis. These results include the impact of post-unblinding changes to the analysis, which did not improve the level of consistency with other data sets compared to the results obtained at the unblinding. The fact that multiple cosmological probes (supernovae, baryon acoustic oscillations, cosmic shear, galaxy clustering and CMB anisotropies), and other galaxy cluster analyses all favor significantly higher matter densities suggests the presence of systematic errors in the data or an incomplete modeling of the relevant physics. Cross checks with X-ray and microwave data, as well as independent constraints on the observable--mass relation from SZ selected clusters, suggest that the discrepancy resides in our modeling of the weak lensing signal rather than the cluster abundance. Repeating our analysis using a higher richness threshold ($λ\ge 30$) significantly reduces the tension with other probes, and points to one or more richness-dependent effects not captured by our model.

preprint2020arXiv

Interplay between phonon downconversion efficiency, density of states at Fermi energy, and intrinsic energy resolution for microwave kinectic inductance detectors

Microwave Kinetic Inductance detectors (MKIDs) have been recognized as a powerful new tool for single photon detection. These highly multiplexed superconducting devices give timing and energy measurement for every detected photon. However, the full potential of MKID single photon spectroscopy has not been reached , the achieved energy resolution is lower than expected from first principles. Here, we study the efficiency in the phonon downconversion process following the absorption of energetic photons in MKIDs. Assuming previously published material properties, we measure an average downconversion efficiency for three TiN resonators is $η$=0.14. We discuss how this efficiency can impact the intrinsic energy resolution of MKID, and how any uncertainty in the unknown density of electron states at the Fermi energy directly affects the efficiency estimations.

preprint2020arXiv

Low Threshold Acquisition controller for Skipper CCDs

The development of the Skipper Charge Coupled Devices (Skipper-CCDs) has been a major technological breakthrough for sensing very weak ionizing particles. The sensor allows to reach the ultimate sensitivity of silicon material as a charge signal sensor by unambiguous determination of the charge signal collected by each cell or pixel, even for single electron-hole pair ionization. Extensive use of the technology was limited by the lack of specific equipment to operate the sensor at the ultimate performance. In this work a simple, single-board Skipper-CCD controller is presented, aimed for the operation of the detector in high sensitivity scientific applications. The article describes the main components and functionality of the Low Threshold Acquisition (LTA) together with experimental results when connected to a Skipper-CCD sensor. Measurements show unprecedented deep sub-electron noise of 0.039 e$^-_{rms}$/pix for 5000 pixel measurements.

preprint2020arXiv

Search for light mediators in the low-energy data of the CONNIE reactor neutrino experiment

The CONNIE experiment is located at a distance of 30 m from the core of a commercial nuclear reactor, and has collected a 3.7 kg-day exposure using a CCD detector array sensitive to an $\sim$1 keV threshold for the study of coherent neutrino-nucleus elastic scattering. Here we demonstrate the potential of this low-energy neutrino experiment as a probe for physics Beyond the Standard Model, by using the recently published results to constrain two simplified extensions of the Standard Model with light mediators. We compare the new limits with those obtained for the same models using neutrinos from the Spallation Neutron Source. Our new constraints represent the best limits for these simplified models among the experiments searching for CE$ν$NS for a light vector mediator with mass $M_{Z^{\prime}}<$ 10 MeV, and for a light scalar mediator with mass $M_ϕ<$ 30 MeV. These results constitute the first use of the CONNIE data as a probe for physics Beyond the Standard Model.

preprint2015arXiv

Discovery of two gravitationally lensed quasars in the Dark Energy Survey

We present spectroscopic confirmation of two new lensed quasars via data obtained at the 6.5m Magellan/Baade Telescope. The lens candidates have been selected from the Dark Energy Survey (DES) and WISE based on their multi-band photometry and extended morphology in DES images. Images of DES J0115-5244 show two blue point sources at either side of a red galaxy. Our long-slit data confirm that both point sources are images of the same quasar at $z_{s}=1.64.$ The Einstein Radius estimated from the DES images is $0.51$". DES J2200+0110 is in the area of overlap between DES and the Sloan Digital Sky Survey (SDSS). Two blue components are visible in the DES and SDSS images. The SDSS fiber spectrum shows a quasar component at $z_{s}=2.38$ and absorption compatible with Mg II and Fe II at $z_{l}=0.799$, which we tentatively associate with the foreground lens galaxy. The long-slit Magellan spectra show that the blue components are resolved images of the same quasar. The Einstein Radius is $0.68$" corresponding to an enclosed mass of $1.6\times10^{11}\,M_{\odot}.$ Three other candidates were observed and rejected, two being low-redshift pairs of starburst galaxies, and one being a quasar behind a blue star. These first confirmation results provide an important empirical validation of the data-mining and model-based selection that is being applied to the entire DES dataset.

preprint2014arXiv

Charge Coupled Devices for detection of coherent neutrino-nucleus scattering

This article details the potential for using Charge Coupled Devices (CCD) to detect low-energy neutrinos through their coherent scattering with nuclei. The detection of neutrinos through this standard model process has not been accessible because of the small energy deposited in such interactions with the detector nuclei. Typical particle detectors have thresholds of a few keV, and most of the energy deposition expected from coherent scattering is well below this level. The devices we discuss can be operated at a threshold of approximately 30 eV, making them ideal for observing this signal. For example, the number of coherent scattering events expected on a 52 gram CCD array located next to a power nuclear reactor is estimated as approximately 626 events/year. The results of our study show that detection at a confidence level of 99% can be reached within three months for this kind of detector array.

preprint2014arXiv

DAMIC at SNOLAB

We introduce the fully-depleted charge-coupled device (CCD) as a particle detector. We demonstrate its low energy threshold operation, capable of detecting ionizing energy depositions in a single pixel down to 50 eVee. We present results of energy calibrations from 0.3 keVee to 60 keVee, showing that the CCD is a fully active detector with uniform energy response throughout the silicon target, good resolution (Fano ~0.16), and remarkable linear response to electron energy depositions. We show the capability of the CCD to localize the depth of particle interactions within the silicon target. We discuss the mode of operation and unique imaging capabilities of the CCD, and how they may be exploited to characterize and suppress backgrounds. We present the first results from the deployment of 250 um thick CCDs in SNOLAB, a prototype for the upcoming DAMIC100. DAMIC100 will have a target mass of 0.1 kg and should be able to directly test the CDMS-Si signal within a year of operation.

preprint2014arXiv

Development of a novel neutron detection technique by using a boron layer coating a Charge Coupled Device

This article describes the design features and the first test measurements obtained during the installation of a novel high resolution 2D neutron detection technique. The technique proposed in this work consists of a boron layer (enriched in ${^{10}}$B) placed on a scientific Charge Coupled Device (CCD). After the nuclear reaction ${^{10}}$B(n,$α$)${^{7}}$Li, the CCD detects the emitted charge particles thus obtaining information on the neutron absorption position. The above mentioned ionizing particles, with energies in the range 0.5-5.5 MeV, produce a plasma effect in the CCD which is recorded as a circular spot. This characteristic circular shape, as well as the relationship observed between the spot diameter and the charge collected, is used for the event recognition, allowing the discrimination of undesirable gamma events. We present the first results recently obtained with this technique, which has the potential to perform neutron tomography investigations with a spatial resolution better than that previously achieved. Numerical simulations indicate that the spatial resolution of this technique will be about 15 $μ$m, and the intrinsic detection efficiency for thermal neutrons will be about 3 %. We compare the proposed technique with other neutron detection techniques and analyze its advantages and disadvantages.

preprint2013arXiv

The SOAR Gravitational Arc Survey - I: Survey overview and photometric catalogs

We present the first results of the SOAR (Southern Astrophysical Research) Gravitational Arc Survey (SOGRAS). The survey imaged 47 clusters in two redshift intervals centered at $z=0.27$ and $z=0.55$, targeting the richest clusters in each interval. Images were obtained in the $g'$, $r'$ and $i'$ bands using the SOAR Optical Imager (SOI), with a median seeing of 0.83, 0.76 and 0.71 arcsec, respectively, in these filters. Most of the survey clusters are located within the Sloan Digital Sky Survey (SDSS) Stripe 82 region and all of them are in the SDSS footprint. Photometric calibration was therefore performed using SDSS stars located in our SOI fields. We reached for galaxies in all fields the detection limits of $g \sim 23.5$, $r \sim 23$ and $i \sim 22.5$ for a signal-to-noise ratio (S/N) = 3. As a by-product of the image processing, we generated a source catalogue with 19760 entries, the vast majority of which are galaxies, where we list their positions, magnitudes and shape parameters. We compared our galaxy shape measurements to those of local galaxies and concluded that they were not strongly affected by seeing. From the catalogue data, we are able to identify a red sequence of galaxies in most clusters in the lower $z$ range. We found 16 gravitational arc candidates around 8 clusters in our sample. They tend to be bluer than the central galaxies in the lensing cluster. A preliminary analysis indicates that $\sim 10%$ of the clusters have arcs around them, with a possible indication of a larger efficiency associated to the high-$z$ systems when compared to the low-$z$ ones. Deeper follow-up images with Gemini strengthen the case for the strong lensing nature of the candidates found in this survey.

preprint2011arXiv

Achieving sub-electron readout noise in Skipper CCDs

The readout noise for Charge-Coupled Devices (CCDs) has been the main limitation when using these detectors for measuring small amplitude signals. A readout system for a new scientific, low noise CCD is presented in this paper. The Skipper CCD architecture, and its advantages for low noise applications are discussed. A technique for obtaining sub-electron readout noise levels is presented, and its noise and signal characteristics are derived. We demonstrate a very low readout noise of $0.2e^{-}$ RMS. Also, we show the results using the detector in a low-energy X-ray detection experiment.

preprint2011arXiv

Deep sub electron noise readout in CCD systems using digital filtering techniques

Scientific CCDs designed in thick high resistivity silicon (Si) are excellent detectors for astronomy, high energy and nuclear physics, and instrumentation. Many applications can benefit from CCDs ultra low noise readout systems. The present work shows how sub electron noise CCD images can be achieved using digital signal processing techniques. These techniques allow readout bandwidths of up to 10 K pixels per second and keep the full CCD spatial resolution and signal dynamic range.

preprint2011arXiv

Plasma effect in Silicon Charge Coupled Devices (CCDs)

Plasma effect is observed in CCDs exposed to heavy ionizing alpha-particles with energies in the range 0.5 - 5.5 MeV. The results obtained for the size of the charge clusters reconstructed on the CCD pixels agrees with previous measurements in the high energy region (>3.5 MeV). The measurements were extended to lower energies using alpha-particles produced by (n,alpha) reactions of neutrons in a Boron-10 target. The effective linear charge density for the plasma column is measured as a function of energy. The results demonstrate the potential for high position resolution in the reconstruction of alpha particles, which opens an interesting possibility for using these detectors in neutron imaging applications.

preprint2009arXiv

Direct Dark Matter Search using CCDs

There is currently vast evidence for Dark Matter (DM) from astronomical observations. However, in spite of tremendous efforts by large experimental groups, there is no confirmed direct detection of the dark matter in our galaxy. Recent experimental results and theoretical developments suggest the possibility of a DM particle with mass below 10 GeV, such a particle would escape most of the direct searches due to the large thresholds for the detection of nuclear recoils typically used. In this work we study the possibility of a new Dark Matter search with an unprecedented low threshold for the detection of nuclear recoils using high-resistivity CCD detectors (hr-CCD). Due to their extremely low readout noise and the relatively large active mass, these detectors present a unique opportunity in this field.

preprint2008arXiv

The Correlation Function of Optically Selected Galaxy Clusters in the Sloan Digital Sky Survey

We measure the two-point spatial correlation function for clusters selected from the photometric MaxBCG galaxy cluster catalog for the Sloan Digital Sky Survey (SDSS). We evaluate the correlation function for several cluster samples using different cuts in cluster richness. Fitting the results to power-laws, $ξ_{cc}(r) = (r/R_0)^{-γ}$, the estimated correlation length $R_0$ as a function of richness is broadly consistent with previous cluster observations and with expectations from N-body simulations. We study how the linear bias parameter scales with richness and compare our results to theoretical predictions. Since these measurements extend to very large scales, we also compare them to models that include the baryon acoustic oscillation feature and that account for the smoothing effects induced by errors in the cluster photometric redshift estimates. For the largest cluster sample, corresponding to a richness threshold of $\Ng\ge 10$, we find only weak evidence, of about $1.4-1.7σ$ significance, for the baryonic acoustic oscillation signature in the cluster correlation function.

preprint1997arXiv

Dynamical Cosmological Constant and Relations Among Pseudo Goldstone Bosons

The present apparent cosmological constant is interpreted as the potential of the lightest pseudo Goldstone boson. Some numerical relations among cosmological parameters and particle masses are shown to arise from the mixture of this very light particle, whose interaction is of the gravitational order, with other pseudo Goldstone bosons like the pion and the axion which feel the strong interaction.