Source author record

Giorgio Carelli

Giorgio Carelli appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

7works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2020arXiv

An underground Sagnac gyroscope with sub-prad/s rotation rate sensitivity: toward General Relativity tests on Earth

Measuring in a single location on Earth its angular rotation rate with respect to the celestial frame, with a sensitivity enabling access to the tiny Lense-Thirring effect is an extremely challenging task. GINGERINO is a large frame ring laser gyroscope, operating free running and unattended inside the underground laboratory of the Gran Sasso, Italy. The main geodetic signals, i.e., Annual and Chandler wobbles, daily polar motion and Length of the Day, are recovered from GINGERINO data using standard linear regression methods, demonstrating a sensitivity better than 1 prad/s, therefore close to the requirements for an Earth-based Lense-Thirring test.

preprint2019arXiv

Analysis of ring laser gyroscopes including laser dynamics

Inertial sensors stimulate very large interest, not only for their application but also for fundamental physics tests. Ring laser gyros, which measure angular rotation rate, are certainly among the most sensitive inertial sensors, with excellent dynamic range and bandwidth. Large area ring laser gyros are routinely able to measure fractions of prad/s, with high duty cycle and bandwidth, providing fast, direct and local measurement of relevant geodetic and geophysical signals. Improvements of a factor $10-100$ would open the windows for general relativity tests, as the GINGER project, an Earth based experiment aiming at the Lense-Thirring test at $1\%$ level. However, it is well known that the dynamics of the laser induces non-linearities, and those effects are more evident in small scale instruments. Sensitivity and accuracy improvements are always worthwhile, and in general there is demand for high sensitivity environmental study and development of inertial platforms, where small scale transportable instruments should be used. We discuss a novel technique to analyse the data, aiming at studying and removing those non-linearity. The analysis is applied to the two ring laser prototypes GP2 and GINGERINO, and angular rotation rate evaluated with the new and standard methods are compared. The improvement is evident, it shows that the back-scatter problem of the ring laser gyros is negligible with a proper analysis of the data, improving the performances of large scale ring laser gyros, but also indicating that small scale instruments with sensitivity of nrad/s are feasible.

preprint2019arXiv

Identification and correction of Sagnac frequency variations: an implementation for the GINGERINO data analysis

Ring laser gyroscopes are top sensitivity inertial sensors used in the measurement of angular rotation rates. It is well known that the response of such remarkable instruments can in principle access the very low frequency band, but the occurrence of nonlinear effects in the laser dynamics imposes severe limitations in terms of sensitivity and stability. We report here general relationships aimed at evaluating corrections able to effectively account for nonlinear laser dynamics. The so-derived corrections are applied to analyse thirty days of continuous operation of the large area ring laser gyroscope GINGERINO leading to duly reconstruct the Sagnac frequency $ω_S$. The analysis shows that, on the average, the evaluated corrections affect the measurement of the Earth rotation rate $Ω_E$ at the level of 1 part in $1.5\times10^{3}$. Among the identified corrections, the null shift term $ω_{NS}$ is the dominant one. It turns out proportional to the optical losses $μ$ of the ring cavity, which are changing in time at the level of $10\%$ within the considered period of thirty days. The time behaviour is reconstructed based on available signals (interferogram and mono-beam intensities), and the Allan deviation of the estimated $Ω_E$ shows a remarkable long term stability, leading to a sensitivity better than $10^{-10}$rad/s with more than $10$s of integration time, and approaching $(8.5\pm 0.5)\times 10^{-12}$rad/s with $4.5\times10^{5}$s of integration time.

preprint2016arXiv

First deep underground observation of rotational signals from an earthquake at teleseismic distance using a large ring laser gyroscope

Recent advances in large ring laser gyroscopes (RLG) technologies opened the possibility to observe rotations of the ground with sensitivities up to $10^{-11}$ $\frac{rad}{s}$ over the frequency band of seismological interest (0.01-1Hz), thus opening the way to a new geophysical discipline, i.e. rotational seismology. A measure of rotations in seismology is of fundamental interest for (a) the determination of all the six degrees of freedom that characterize a rigid body motion, and (b) the quantitative estimate of the rotational motions contaminating ground translation measurements obtained from standard seismometers. Within this framework, this paper presents and describes GINGERino, a new large observatory-class RLG located in Gran Sasso underground laboratory (LNGS), one national laboratories of the INFN (Istituto Nazionale di Fisica Nucleare). We also report unprecedented observations and analyses of the roto-translational signals from a tele-seismic event observed in such a deep underground environment.

preprint2011arXiv

A 1.82 m^2 ring laser gyroscope for nano-rotational motion sensing

We present a fully active-controlled He-Ne ring laser gyroscope, operating in square cavity 1.35 m in side. The apparatus is designed to provide a very low mechanical and thermal drift of the ring cavity geometry and is conceived to be operative in two different orientations of the laser plane, in order to detect rotations around the vertical or the horizontal direction. Since June 2010 the system is active inside the Virgo interferometer central area with the aim of performing high sensitivity measurements of environmental rotational noise. So far, continuous not attempted operation of the gyroscope has been longer than 30 days. The main characteristics of the laser, the active remote-controlled stabilization systems and the data acquisition techniques are presented. An off-line data processing, supported by a simple model of the sensor, is shown to improve the effective long term stability. A rotational sensitivity at the level of ten nanoradiants per squareroot of Hz below 1 Hz, very close to the required specification for the improvement of the Virgo suspension control system, is demonstrated for the configuration where the laser plane is horizontal.

preprint2011arXiv

Measuring the Virgo area tilt noise with a laser gyroscope

We report on the measurements of tilt noise performed at the Virgo site with a ring laser gyroscope. The apparatus is a He-Ne laser operating in a square cavity mounted on a vertical plane perpendicular to the north-south arm of the inteferometer. We discuss the possibility of using the ring laser signal to improve the performances of the control system of the Virgo seismic suspensions. The comparison between the ring laser signal and the control signals for the longitudinal translations of the inverted pendulum (IP) shows remarkable coherence in the frequency range 20-200 mHz.

preprint2010arXiv

Rotational sensitivity of the "G-Pisa" gyrolaser

G-Pisa is an experiment investigating the possibility to operate a high sensitivity laser gyroscope with area less than $1 \rm m^2$ for improving the performances of the mirrors suspensions of the gravitational wave antenna Virgo. The experimental set-up consists in a He-Ne ring laser with a 4 mirrors square cavity. The laser is pumped by an RF discharge where the RF oscillator includes the laser plasma in order to reach a better stability. The contrast of the Sagnac fringes is typically above 50% and a stable regime has been reached with the laser operating both single mode or multimode. The effect of hydrogen contamination on the laser was also checked. A low-frequency sensitivity, below $1 \rm Hz$, in the range of $10^{-8} \rm {(rad / s)/ \sqrt{Hz}}$ has been measured.