Source author record

Giacomo Traini

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

2works
2topics
4close collaborators

Published work

2 publications

preprint2016arXiv

Design of a new tracking device for on-line dose monitor in ion therapy

Charged Particle Therapy is a technique for cancer treatment that exploits hadron beams, mostly protons and carbons. A critical issue is the monitoring of the dose released by the beam to the tumor and to the surrounding tissues. We present the design of a new tracking device for monitoring on-line the dose in ion therapy through the detection of secondary charged particles produced by the beam interactions in the patient tissues. In fact, the charged particle emission shape can be correlated with the spatial dose release and the Bragg peak position. The detector uses the information provided by 12 layers of scintillating fibers followed by a plastic scintillator and a small calorimeter made of a pixelated Lutetium Fine Silicate crystal. Simulations have been performed to evaluate the achievable spatial resolution and a possible application of the device for the monitoring of the dose profile in a real treatment is presented.

preprint2016arXiv

Feasibility of the β−β^- Radio-Guided Surgery with a Variety of Radio-Nuclides of Interest to Nuclear Medicine

The β−β^- based radio-guided surgery overcomes the corresponding γγ technique in case the background from healthy tissues is relevant. It can be used only in case a radio-tracer marked with 90^{90}Y is available since the current probe prototype was optimized for the emission spectrum of this radio-nuclide. Here we study, with a set of laboratory tests and simulations, the prototype capability in case a different radio-nuclide is chosen among those used in nuclear medicine. As a result we estimate the probe efficiency on electrons and photons as a function of energy and we evaluate the feasibility of a radio-guided surgery exploiting the selected radio-nuclides. We conclude that requiring a 0.1~ml residue to be detected within 1~s by administering 3~MBq/Kg of radio-isotope, the current probe prototype would yield a significant signal in a vast range of values of SUV and TNR in case 31^{31}Si,32^{32}P, 97^{97}Zr, and 188^{188}Re are used. Conversely, a tuning of the detector would be needed to efficiency use 83^{83}Br, 133^{133}I, and 153^{153}Sm, although they could already be used in case of high SUV or TNR values. Finally, 18^{18}F,67^{67}Cu, 131^{131}I, and 177^{177}Lu are not useable for radio-guided surgery with the current probe design.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.