Researcher profile

Gerard van Harten

Gerard van Harten contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2014arXiv

Exact Bound-Bound Gaunt Factor Values for Quantum Levels up to n=2000

Comparison of observations of radio recombination lines in the interstellar medium with theoretical models can be used to constrain electron temperature and density of the gas. An important component of the models is spontaneous transition rates between bound levels. Calculating these rates relies on accurate bound-bound oscillator strengths, which can be cast in terms of the Gaunt factor. The Gaunt factor contains terminating hypergeometric functions that cannot be calculated with sufficient accuracy for high quantum levels ($n \gtrsim 50$) by standard machine-precision methods. Methods to overcome the accuracy problem have been developed, which include asymptotic expansions and recursion relations. These methods, used in astrophysical models to calculate oscillator strengths, can introduce errors, sometimes up to as much as $\sim 8$ per cent. Detections of radio recombination lines with the new Low Frequency Array (LOFAR) has prompted an examination of theoretical models of the interstellar medium. We revisit the calculation of the Gaunt factor, employing modern arbitrary-precision computational methods to tabulate the Gaunt factor for transitions up to quantum level $n=2000$, sufficient to model low frequency Carbon radio recombination lines. The calculations provide a relative error of $\sim3\times 10^{-4}$ when compared to more detailed calculations including relativistic corrections. Our values for the Gaunt factor are provided for download in a tabular format to be used for a wide range of applications.

preprint2014arXiv

UVMag: Space UV and visible spectropolarimetry

UVMag is a project of a space mission equipped with a high-resolution spectropolarimeter working in the UV and visible range. This M-size mission will be proposed to ESA at its M4 call. The main goal of UVMag is to measure the magnetic fields, winds and environment of all types of stars to reach a better understanding of stellar formation and evolution and of the impact of stellar environment on the surrounding planets. The groundbreaking combination of UV and visible spectropolarimetric observations will allow the scientists to study the stellar surface and its environment simultaneously. The instrumental challenge for this mission is to design a high-resolution space spectropolarimeter measuring the full-Stokes vector of the observed star in a huge spectral domain from 117 nm to 870 nm. This spectral range is the main difficulty because of the dispersion of the optical elements and of birefringence issues in the FUV. As the instrument will be launched into space, the polarimetric module has to be robust and therefore use if possible only static elements. This article presents the different design possibilities for the polarimeter at this point of the project.

preprint2012arXiv

Design of a Full-Stokes Polarimeter for VLT/X-shooter

X-shooter is one of the most popular instruments at the VLT, offering instantaneous spectroscopy from 300 to 2500 nm. We present the design of a single polarimetric unit at the polarization-free Cassegrain focus that serves all three spectrograph arms of X-shooter. It consists of a calcite Savart plate as a polarizing beam-splitter and a rotatable crystal retarder stack as a "polychromatic modulator". Since even "superachromatic" wave plates have a wavelength range that is too limited for X-shooter, this novel modulator is designed to offer close-to-optimal polarimetric efficiencies for all Stokes parameters at all wavelengths. We analyze the modulator design in terms of its polarimetric performance, its temperature sensitivity, and its polarized fringes. Furthermore, we present the optical design of the polarimetric unit. The X-shooter polarimeter will furnish a myriad of science cases: from measuring stellar magnetic fields (e.g., Ap stars, white dwarfs, massive stars) to determining asymmetric structures around young stars and in supernova explosions.