Source author record

Gerald Hechenblaikner

Gerald Hechenblaikner appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

16works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

16 published item(s)

preprint2022arXiv

Impact of spectral noise shape and correlations of laser beam jitter on acquiring optical links in space

We investigate how the probability of acquiring an optical link between a scanning and a target spacecraft depends on the spectral shape, power and dimensionality of the beam jitter, as well as on the choice of detector integration time, beam detection radius and scan speed. For slow scans and long integration times, the probability of failure (Pfail) is determined by the integrated jitter power up to a critical frequency, which we verify by comparing the results of an analytical model to those of Monte Carlo simulations. Jitter above the critical frequency leads to a loss of correlation between integration windows and decreases Pfail for both, 1d (radial) and 2d (radial and tangential) jitter, as long as the RMS jitter amplitude does not exceed the beam diameter. In the opposite limit of fast scans and short integration times, emergent correlations between jitter fluctuations on two adjacent scanning tracks also decrease Pfail. The analytical model is additionally used to assess the effect of multiple overlapping tracks and the impact of target drifts in the uncertainty plane.

preprint2022arXiv

LISA Point-Ahead Angle Control for Optimal Tilt-to-Length Noise Estimation

The Laser Interferometer Space Antenna (LISA) mission features a three-spacecraft long-arm constellation intended to detect gravitational wave sources in the low-frequency band up to 1 Hz via laser interferometry. The paper presents an open-loop control strategy for point-ahead angle (PAA) correction required to maintain the optical links of the moving constellation. The control strategy maximizes periods between adjustments at the constellation level and is shown to be optimal from the perspective of estimating and correcting tilt-to-length (TTL) coupling. TTL is a noise source that couples angular spacecraft jitter and jitter of optical subassemblies with longitudinal interferometer measurements. Without precise TTL noise estimation and correction, TTL coupling fundamentally limits the detector's sensitivity.

preprint2022arXiv

MAQRO -- BPS 2023 Research Campaign Whitepaper

The objective of the proposed MAQRO mission is to harness space for achieving long free-fall times, extreme vacuum, nano-gravity, and cryogenic temperatures to test the foundations of physics in macroscopic quantum experiments. This will result in the development of novel quantum sensors and a means to probe the foundations of quantum physics at the interface with gravity. Earlier studies showed that the proposal is feasible but that several critical challenges remain, and key technologies need to be developed. These new technologies will open up the potential for achieving additional science objectives. The proposed research campaign aims to advance the state of the art and to perform the first macroscopic quantum experiments in space. Experiments on the ground, in micro-gravity, and in space will drive the proposed research campaign during the current decade to enable the implementation of MAQRO within the subsequent decade.

preprint2015arXiv

Macroscopic quantum resonators (MAQRO): 2015 Update

Do the laws of quantum physics still hold for macroscopic objects - this is at the heart of Schrödinger's cat paradox - or do gravitation or yet unknown effects set a limit for massive particles? What is the fundamental relation between quantum physics and gravity? Ground-based experiments addressing these questions may soon face limitations due to limited free-fall times and the quality of vacuum and microgravity. The proposed mission MAQRO may overcome these limitations and allow addressing those fundamental questions. MAQRO harnesses recent developments in quantum optomechanics, high-mass matter-wave interferometry as well as state-of-the-art space technology to push macroscopic quantum experiments towards their ultimate performance limits and to open new horizons for applying quantum technology in space. The main scientific goal of MAQRO is to probe the vastly unexplored "quantum-classical" transition for increasingly massive objects, testing the predictions of quantum theory for truly macroscopic objects in a size and mass regime unachievable in ground-based experiments. The hardware for the mission will largely be based on available space technology. Here, we present the MAQRO proposal submitted in response to the (M4) Cosmic Vision call of the European Space Agency for a medium-size mission opportunity with a possible launch in 2025.

preprint2015arXiv

Performance of a radiatively cooled system for quantum optomechanical experiments in space

The performance of a radiatively cooled instrument is investigated in the context of optomechanical quantum experiments, where the environment of a macroscopic particle in a quantum-superposition has to be cooled to less than 20\,K in deep space. A heat-transfer analysis between the components of the instrument as well as a transfer-function analysis on thermal oscillations induced by the spacecraft interior and by dissipative sources is performed. The thermal behaviour of the instrument in an orbit around a Lagrangian point and in a highly elliptical Earth orbit is discussed. Finally, we investigate further possible design improvements aiming at lower temperatures of the environment of the macroscopic particle. These include a mirror-based design of the imaging system on the optical bench and the extension of the heat shields.

preprint2014arXiv

STE-QUEST Mission and System Design - Overview after completion of Phase-A

STE-QUEST is a fundamental science mission which is considered for launch within the Cosmic Vision programme of the European Space Agency (ESA). Its main scientific objectives relate to probing various aspects of Einstein's theory of general relativity by measuring the gravitational red-shift of the earth, the moon and the sun as well as testing the weak equivalence principle to unprecedented accuracy. In order to perform the measurements, the system features a spacecraft equipped with two complex instruments, an atomic clock and an atom interferometer, a ground-segment encompassing several ground-terminals collocated with the best available ground atomic clocks, and clock comparison between space and ground via microwave and optical links. The baseline orbit is highly eccentric and exhibits strong variations of incident solar flux, which poses challenges for thermal and power subsystems in addition to the difficulties encountered by precise-orbit-determination at high altitudes. The mission assessment and definition phase (Phase-A) has recently been completed and this paper gives a concise overview over some system level results.

preprint2014arXiv

The vectorial photoelectric effect under solar irradiance and its application to sun sensing

Sun sensors are an integral part of the attitude and orbit control system onboard almost any spacecraft. While the majority of standard analogue sun sensors is based on photo-detectors which produce photo-currents proportional to the cosine of the incidence angle (cosine detectors), we propose an alternative scheme where the vectorial photoelectric effect is exploited to achieve a higher sensitivity of the sensed photo-current to the incidence angle. The vectorial photo-effect is investigated in detail for metal cathode detectors in a space environment. Besides long operational lifetimes without significant degradation, metal cathode detectors are insensitive to earth albedo, which may significantly reduce the errors affecting attitude measurements in low earth orbits. Sensitivity curves are calculated and trade-offs performed with the aim of optimizing the sensitivity whilst also providing currents sufficient for detection. Simple applications and detector configurations are also discussed and compared to existing designs.

preprint2013arXiv

Common mode noise rejection properties of amplitude and phase noise in a heterodyne interferometer

High precision metrology systems based on heterodyne interferometry can measure position and attitude of objects to accuracies of picometer and nanorad, respectively. A frequently found feature of the general system design is the subtraction of a reference phase from the phase of the position interferometer, which suppresses low frequency common mode amplitude and phase fluctuations occurring in volatile optical path sections shared by both, the position and reference interferometer. Spectral components of the noise at frequencies around or higher than the heterodyne frequency, however, are generally transmitted into the measurement band and may limit the measurement accuracy. Detailed analytical calculations complemented with Monte Carlo simulations show that high frequency noise components may also be entirely suppressed, depending on the relative difference of measurement and reference phase, which may be exploited by corresponding design provisions. Whilst these results are applicable to any heterodyne interferometer with certain design characteristics, specific calculations and related discussions are given for the example of the optical metrology system of the LISA Pathfinder mission to space.

preprint2013arXiv

Fundamental Performance Determining Factors of the Ultrahigh-Precision Space-Borne Optical Metrology System for the LISA Pathfinder mission

The LISA Pathfinder mission to space employs an optical metrology system (OMS) at its core to measure the distance and attitude between two freely floating test-masses to picometer and nanorad accuracy, respectively, within the measurement band of [1 mHz, 30 mHz]. The OMS is based upon an ultra-stable optical bench with 4 heterodyne interferometers from which interference signals are read-out and processed by a digital phase-meter. Laser frequency noise, power fluctuations and optical path-length variations are suppressed to uncritical levels by dedicated control loops so that the measurement performance approaches the sensor limit imposed by the phase-meter. The system design is such that low frequency common mode noise which affects the read-out phase of all four interferometers is generally well suppressed by subtraction of a reference phase from the other interferometer signals. However, high frequency noise directly affects measurement performance and its common mode rejection depends strongly on the relative signal phases. We discuss how the data from recent test campaigns point towards high frequency phase noise as a likely performance limiting factor which explains some important performance features.

preprint2013arXiv

How cold can you get in space? Quantum Physics at cryogenic temperatures in space

Although it is often believed that the coldness of space is ideally suited for performing measurements at cryogenic temperatures, this must be regarded with caution for two reasons: Firstly, the sensitive instrument must be completely shielded from the strong solar radiation and therefore, e.g. either be placed inside a satellite or externally on the satellite's shaded side. Secondly, any platform hosting such an experiment in space generally provides an environment close to room temperature for the accommodated equipment. To obtain cryogenic temperatures without active cooling, one must isolate the instrument from radiative and conductive heat exchange with the platform as well as possible. We investigate the limits of this passive cooling method in the context of a recently proposed experiment to observe the decoherence of quantum superpositions of massive objects. The analyses and conclusions are applicable to a host of similar experimental designs requiring a cryogenic environment in space.

preprint2012arXiv

Digital laser frequency control and phase stabilization loops for a high precision space-borne metrology system

We report on the design, implementation and characterization of fully digital control loops for laser frequency stabilization, differential phase-locking and performance optimization of the optical metrology system on-board the LISA Pathfinder space mission. The optical metrology system consists of a laser with modulator, four Mach-Zehnder interferometers, a phase-meter and a digital processing unit for data analysis. The digital loop design has the advantage of easy and flexible controller implementation and loop calibration, automated and flexible locking and resetting, and improved performance over analogue circuitry. Using the practical ability of our system to modulate the laser frequency allows us to accurately determine the open loop transfer function and other system properties. Various noise sources and their impact on system performance are investigated in detail.

preprint2012arXiv

Energy distribution and quantum yield for photoemission from air-contaminated gold surfaces under UV illumination close to the threshold

The kinetic energy distributions of photo-electrons emitted from gold surfaces under illumination by UV-light close to the threshold are measured and analyzed. Samples are prepared as chemically clean through Ar-Ion sputtering and then exposed to atmosphere for variable durations before Quantum Yield measurements are performed after evacuation. During measurements the bias voltage applied to the sample is varied and the resulting emission current measured. Taking the derivative of the current-voltage curve yields the energy distribution which is found to closely resemble the distribution of total energies derived by DuBridge for emission from a free electron gas. We investigate the dependence of distribution shape and width on electrode geometry and contaminant substances adsorbed from the atmosphere, in particular to water and hydro-carbons. Emission efficiency increases initially during air exposure before diminishing to zero on a timescale of several hours, whilst subsequent annealing of the sample restores emissivity. A model fit function, in good quantitative agreement with the measured data, is introduced which accounts for the experiment-specific electrode geometry and an energy dependent transmission coefficient. The impact of large patch potential fields from contact potential drops between sample and sample holder is investigated. The total quantum yield is split into bulk and surface contributions which are tested for their sensitivity to light incidence angle and polarization. Our results are directly applicable to model parameters for the contact-free discharge system onboard the LISA Pathfinder spacecraft.

preprint2012arXiv

Macroscopic quantum resonators (MAQRO)

Quantum physics challenges our understanding of the nature of physical reality and of space-time and suggests the necessity of radical revisions of their underlying concepts. Experimental tests of quantum phenomena involving massive macroscopic objects would provide novel insights into these fundamental questions. Making use of the unique environment provided by space, MAQRO aims at investigating this largely unexplored realm of macroscopic quantum physics. MAQRO has originally been proposed as a medium-sized fundamental-science space mission for the 2010 call of Cosmic Vision. MAQRO unites two experiments: DECIDE (DECoherence In Double-Slit Experiments) and CASE (Comparative Acceleration Sensing Experiment). The main scientific objective of MAQRO, which is addressed by the experiment DECIDE, is to test the predictions of quantum theory for quantum superpositions of macroscopic objects containing more than 10e8 atoms. Under these conditions, deviations due to various suggested alternative models to quantum theory would become visible. These models have been suggested to harmonize the paradoxical quantum phenomena both with the classical macroscopic world and with our notion of Minkowski space-time. The second scientific objective of MAQRO, which is addressed by the experiment CASE, is to demonstrate the performance of a novel type of inertial sensor based on optically trapped microspheres. CASE is a technology demonstrator that shows how the modular design of DECIDE allows to easily incorporate it with other missions that have compatible requirements in terms of spacecraft and orbit. CASE can, at the same time, serve as a test bench for the weak equivalence principle, i.e., the universality of free fall with test-masses differing in their mass by 7 orders of magnitude.

preprint2012arXiv

Modeling and Performance of Contact-Free Discharge Systems for Space Inertial Sensors

This article presents a detailed overview and assessment of contact-free UV light discharge systems (UVDS) needed to control the variable electric charge level of free-flying test masses which are part of high precision inertial sensors in space. A comprehensive numerical analysis approach on the basis of experimental data is detailed. This includes UV light ray tracing, the computation of time variant electric fields inside the complex inertial sensor geometry, and the simulation of individual photo-electron trajectories. Subsequent data analysis allows to determine key parameters to set up an analytical discharge model. Such a model is an essential system engineering tool needed for requirement breakdown and subsystem specification, performance budgeting, on-board charge control software development, and instrument modeling within spacecraft end-to-end performance simulators. Different types of UVDS design concepts are presented and assessed regarding their robustness and performance. Critical hardware aspects like electron emission from air-contaminated surfaces, interfaces with other subsystems, and spacecraft operations are considered. The focus is on the modeling and performance evaluation of the existing UVDS on board LISA Pathfinder, an ESA technology demonstrator spacecraft to be launched in 2014. The results have motivated the design of a more robust discharge system concept for cubical test mass inertial sensors for future space missions. The developed analysis tools have been used for design optimization and performance assessment of the proposed design. A significant improvement of relevant robustness and performance figures has been achieved.

preprint2012arXiv

Probing the Flyby Anomaly with the future STE-QUEST mission

In this study, we demonstrate that the flyby anomaly, an unexpected acceleration detected in some of the gravitational assists of the Galileo, NEAR, Cassini and Rosetta spacecraft, could be probed by accurate orbital tracking available in the proposed Space-Time Explorer and Quantum Equivalence Principle Space Test (STE- QUEST); following a recent work, we focus on the similarity between an hyperbolic flyby and the perigee passage in a highly elliptic orbit of the latter, as well as its Global Navigation Satellite System precise orbital determination capabilities.

preprint2010arXiv

Measurement of the absolute wavefront curvature radius in a heterodyne interferometer

We present an analytical derivation of the coupling parameter relating the angle between two interfering beams in a heterodyne interferometer to the differential phase-signals detected by a quadrant photo-diode. This technique, also referred to as Differential Wavefront Sensing (DWS), is commonly used in space-based gravitational wave detectors to determine the attitude of a test-mass in one of the interferometer arms from the quadrant diode signals. Successive approximations to the analytical expression are made to simplify the investigation of parameter dependencies. Motivated by our findings, we propose a new measurement method to accurately determine the absolute wave-front curvature of a single measurement beam. We also investigate the change in coupling parameter when the interferometer "test-mirror" is moved from its nominal position, an effect which mediates the coupling of mirror displacement noise into differential phase-measurements.