Researcher profile

Gaëtan Hagel

Gaëtan Hagel contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - Baseline
3works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2009arXiv

Some aspects of simulation and realization of an optical reference cavity

The interrogation of an ultra-narrow clock transition of a single trapped ion for optical frequency metrology requires a laser stabilized to a couple of Hz per second with a linewidth of the same order of magnitude. Today, lasers in the visible have reached the Hz-range in frequency stability, if locked onto a high-finesse, ultra-stable reference cavity. Vertical mounting of the reference cavity can reduce its sensitivity to vibrations as described in \cite{notcutt05}. We have designed a comparable vertical cavity with an overall length of 150 mm resulting in a Free Spectral Range of 1GHz. Optimisation of the cavity design has been carried out with a Finite-Elements Method, leading to expected relative length variations below 10$^{-14}$ under the influence of gravity acceleration (1 $g$). The variation of different geometric parameters has been studied. The analysis of the different noise sources shows that, for a regime superior to a tenth of a hertz, the fast linewidth of the laser will not be limited by the cavity characteristics.

preprint2005arXiv

Comment on "Prospect of optical frequency standard based on a 43Ca+ ion"

A recent evaluation of the frequency uncertainty expected for an optical frequency standard based on a single trapped $^{43}$Ca$^+$ ion was published in Phys. Rev. A {\bf 72} (2005) 043404. The paper contains some interesting information like systematic frequency shifts but fails to depict their uncertainty, leading to confuse accuracy and precision. The conclusions about the major contribution to the frequency shift are not consistent with the presented calculations and omit comparisons with data published previously.

preprint2005arXiv

Long-term stabilization of the length of an optical reference cavity

To obtain a high degree of long-term length stabilisation of an optical reference cavity, its free-spectral range is locked by means of an accurate and stable frequency synthesizer. The locking scheme is twofold: a laser is locked on the N$^{th}$ mode of a reference Fabry-Perot cavity and part of the laser light is shifted in frequency to be in resonance with the (N+1)$^{th}$ mode of the cavity. This shift is generated by an acousto-optical modulator (AOM) mounted in a double-pass scheme, matching half of the free spectral range of the reference cavity. The resulting absolute stabilization of the length of the cavity reaches the 10$^{-11}$ level per second, limited by the lock transfer properties and the frequency stability of the AOM control synthesizer.