Source author record

G. S. Harutyunyan

G. S. Harutyunyan appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2026arXiv

Monitoring of structural changes in materials under the exposure of ionization radiation using a vibrating wire

Ionizing radiation (X-rays, proton beams) causes structural changes in materials. If a vibrating metallic wire is subjected to such radiation, the natural frequency of the wire is affected as a result of changes in the elastic characteristics of the material. This paper presents the results of experiments on the impact of X-ray radiation in the range of 100-165 keV and a proton beam with energy 18 MeV on the structure of stainless steel wire. In case of proton irradiation an irreversible change in the wire frequency was observed, which indicated residual changes in the structure of the wire material. X-ray diffractometry methods were used to analyze the structural changes.

preprint2015arXiv

Multiwavelength studies of X-ray selected extragalactic sample

The joint catalogue of Active Galactic Nuclei selected from optical identifications of X-ray sources was created as a combination of two samples: Hamburg-ROSAT Catalogue (HRC) and Byurakan-Hamburg-ROSAT Catalogue (BHRC). Both are based on optical identifications of X-ray sources from ROSAT catalogues using low-dispersion spectra of Hamburg Quasar Survey (HQS). However, HRC and BHRC contain a number of misidentifications and using the recent optical and multiwavelength (MW) catalogues we have revised both samples excluding false AGN and adding new genuine ones. Thus a new large homogeneous complete sample of 4253 X-ray selected AGN was created. 3352 of them are listed in the Catalogue of QSOs and Active Galaxies and 387 also are in Roma Multifrequency Catalogue of Blazars. 901 candidate AGN are subject for further study. We classified 173 of these objects using their SDSS DR12 spectra. Following activity types were revealed: 61 AGN, 21 HII galaxies, 12 emission-line galaxies without definite type, 71 absorption-line galaxies, 2 stars, and 6 were classified as "Unknown". A special emphasis is made on narrow-line Sy1.0-Sy1.5 galaxies and QSOs, as many of them have soft X-ray, strong FeII lines, and relatively narrow lines coming from BLR ("narrow broad lines"). As a result, the sample of genuine AGN was enlarged to 3413 objects. We have retrieved MW data from recent catalogues and carried out statistical investigations for the whole AGN sample. An attempt to find connections between fluxes in different bands for different types of sources, and identify their characteristics thus confirming candidate AGNs have been carried out. We have analyzed X-ray properties of these sources to find a limit between normal galaxies and X-ray AGN.

preprint2015arXiv

Proposal of thermal neutron flux monitors based on vibrating wire

Two types of neutron monitors with fine spatial resolution are proposed based on vibrating wire. In the first type, neutrons interact with the vibrating wire, heat it, and lead to the change of natural frequency, which can be precisely measured. To increase the heat deposition during the neutron scattering, use of gadolinium layer which has the highest thermal neutron capture cross section among all elements is proposed. The second type of the monitor uses vibrating wire as a resonant target. Besides the measurement of beam profile according to the average signal, the differential signal synchronized with the wire oscillations defines the gradient of beam profile. Spatial resolution of the monitor is defined by the diameter of the wire.