Researcher profile

Francisco Gonzalez

Francisco Gonzalez contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2026arXiv

A gaseous-helium cooling system for silicon detectors in the Nab experiment

The Nab experiment aims to extract the neutron beta decay correlation coefficients 'a' and 'b'. This will be accomplished using a 7 m tall electromagnetic spectrometer which measures electron energies and proton momenta. Detection of electrons and protons resulting from neutron beta decay will be carried out using large-area, thick, highly-segmented, single-crystal silicon detectors. These detectors and accompanying electronics will be cooled by a recirculating, gaseous helium cooling system to below 150 K with +/- 0.5 K stability. We will motivate the need for detector cooling in the Nab experiment and discuss design and performance of this cooling system.

preprint2020arXiv

Atom scattering off a vibrating surface: An example of chaotic scattering with three degrees of freedom

In this article, we study the classical chaotic scattering of a He atom off a harmonically vibrating Cu surface. The three degrees of freedom (3- dof) model is studied by first considering the non-vibrating 2-dof model for different values of the energy. We calculate the set of singularities of the scattering functions and study its connection with the tangle between the stable and unstable manifolds of the fixed point at an infinite distance to the Cu surface in the Poincaré map for different values of the initial energy. With these manifolds, it is possible to construct the stable and unstable manifolds for the 3-dof coupled model considering the extra closed degree of freedom and the deformation of a stack of maps of the 2-dof system calculated at different values of the energy. Also, for the 3-dof system, the resulting invariant manifolds have the correct dimension to divide the constant total energy manifold. By this construction, it is possible to understand the chaotic scattering phenomena for the 3-dof system from a geometric point of view. We explain the connection between the set of singularities of the scattering function, the Jacobian determinant of the scattering function, the relevant invariant manifolds in the scattering problem, and the cross-section, as well as their behavior when the coupling due to the surface vibration is switched on. In particular, we present in detail the connection between the changes in the structure of the caustics in the cross-section and the changes in the zero level set of the Jacobian determinant of the scattering function.

preprint2013arXiv

Demonstration of Low Emittance in the Cornell Energy Recovery Linac Injector Prototype

We present a detailed study of the six-dimensional phase space of the electron beam produced by the Cornell Energy Recovery Linac Photoinjector, a high-brightness, high repetition rate (1.3 GHz) DC photoemission source designed to drive a hard x-ray energy recovery linac (ERL). A complete simulation model of the injector has been constructed, verified by measurement, and optimized. Both the horizontal and vertical 2D transverse phase spaces, as well as the time-resolved (sliced) horizontal phase space, were simulated and directly measured at the end of the injector for 19 pC and 77 pC bunches at roughly 8 MeV. These bunch charges were chosen because they correspond to 25 mA and 100 mA average current if operating at the full 1.3 GHz repetition rate. The resulting 90% normalized transverse emittances for 19 (77) pC/bunch were 0.23 +/- 0.02 (0.51 +/- 0.04) microns in the horizontal plane, and 0.14 +/- 0.01 (0.29 +/- 0.02) microns in the vertical plane, respectively. These emittances were measured with a corresponding bunch length of 2.1 +/- 0.1 (3.0 +/- 0.2) ps, respectively. In each case the rms momentum spread was determined to be on the order of 1e-3. Excellent overall agreement between measurement and simulation has been demonstrated. Using the emittances and bunch length measured at 19 pC/bunch, we estimate the electron beam quality in a 1.3 GHz, 5 GeV hard x-ray ERL to be at least a factor of 20 times better than that of existing storage rings when the rms energy spread of each device is considered. These results represent a milestone for the field of high-brightness, high-current photoinjectors.