Source author record

Francesco Iacoangeli

Francesco Iacoangeli appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

The CYGNO Experiment

The search for a novel technology able to detect and reconstruct nuclear and electron recoil events with the energy of a few keV has become more and more important now that large regions of high-mass dark matter (DM) candidates have been excluded. Moreover, a detector sensitive to incoming particle direction will be crucial in the case of DM discovery to open the possibility of studying its properties. Gaseous time projection chambers (TPC) with optical readout are very promising detectors combining the detailed event information provided by the TPC technique with the high sensitivity and granularity of latest-generation scientific light sensors. The CYGNO experiment (a CYGNus module with Optical readout) aims to exploit the optical readout approach of multiple-GEM structures in large volume TPCs for the study of rare events as interactions of low-mass DM or solar neutrinos. The combined use of high-granularity sCMOS cameras and fast light sensors allows the reconstruction of the 3D direction of the tracks, offering good energy resolution and very high sensitivity in the few keV energy range, together with a very good particle identification useful for distinguishing nuclear recoils from electronic recoils. This experiment is part of the CYGNUS proto-collaboration, which aims at constructing a network of underground observatories for directional DM search. A one cubic meter demonstrator is expected to be built in 2022/23 aiming at a larger scale apparatus (30 m$^3$--100 m$^3$) at a later stage.

preprint2015arXiv

A low cost network of spectrometer radiation detectors based on the ArduSiPM a compact transportable Software/Hardware Data Acquisition system with Arduino DUE

The necessity to use Photo Multipliers (PM) as light detector limited in the past the use of crystals in radiation handled device preferring the Geiger approach. The Silicon Photomultipliers (SiPMs) are very small and cheap, solid photon detectors with good dynamic range and single photon detection capability, they are usable to supersede in some application cumbersome and difficult to use Photo Multipliers (PM). A SiPM can be coupled with a scintillator crystal to build efficient, small and solid radiation detector. A cost effective and easily replicable Hardware software module for SiPM detector readout is made using the ArduSiPM solution [1]. The ArduSiPM is an easily battery operable handled device using an Arduino DUE (an open Software/Hardware board) as processor board and a piggy-back custom designed board (ArduSiPM Shield), the Shield contains all the blocks features to monitor, set and acquire the SiPM using internet network.

preprint2014arXiv

The ArduSiPM a compact trasportable Software/Hardware Data Acquisition system for SiPM detector

The acquisition of a single Silicon Photomultiplier require multiple and expensive electronics modules as : preamplifier, discriminator, bias voltage power supply, temperature monitor, Scalers, Analog to Digital Converter and Time to Digital Converter . The developed ArduSiPM is a compact cost effective and easily replicable Hardware software module for SiPM detector readout. The ArduSiPM uses an Arduino DUE (an open Software/Hardware board based on an ARM Cortex-M3 microcontroller) as processor board and a piggyback custom designed board (Shield), these are controlled by custom developed software and interface. The Shield contains different electronics features both to monitor, to set and to acquire the SiPM signals using the microcontroller board. The shield embed a controlled bias voltage power supply, a fast voltage preamplifier, a programmable fast discriminator to generate over threshold digital pulse , a peak hold to measure the pulse height, a temperature monitor system, a scaler to monitor over threshold rate and arrival time of the pulses. A TCP/IP Wi-Fi or Ethernet connection is used both to control and to acquire the ArduSiPM remotely with either a PC software or a Tablet APP (depending on the application).