Researcher profile

Luigi Recchia

Luigi Recchia contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - Baseline
5works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2015arXiv

A low cost network of spectrometer radiation detectors based on the ArduSiPM a compact transportable Software/Hardware Data Acquisition system with Arduino DUE

The necessity to use Photo Multipliers (PM) as light detector limited in the past the use of crystals in radiation handled device preferring the Geiger approach. The Silicon Photomultipliers (SiPMs) are very small and cheap, solid photon detectors with good dynamic range and single photon detection capability, they are usable to supersede in some application cumbersome and difficult to use Photo Multipliers (PM). A SiPM can be coupled with a scintillator crystal to build efficient, small and solid radiation detector. A cost effective and easily replicable Hardware software module for SiPM detector readout is made using the ArduSiPM solution [1]. The ArduSiPM is an easily battery operable handled device using an Arduino DUE (an open Software/Hardware board) as processor board and a piggy-back custom designed board (ArduSiPM Shield), the Shield contains all the blocks features to monitor, set and acquire the SiPM using internet network.

preprint2015arXiv

An Intraoperative $β^-$ Detecting Probe For Radio-Guided Surgery in Tumour Resection

The development of the $β^-$ based radio-guided surgery aims to extend the technique to those tumours where surgery is the only possible treatment and the assessment of the resection would most profit from the low background around the lesion, as for brain tumours. Feasibility studies on meningioma, glioma, and neuroendocrine tumors already estimated the potentiality of this new treatment. To validate the technique, prototypes of the intraoperative probe required by the technique to detect $β^-$ radiation have been developed. This paper discusses the design details of the device and the tests performed in laboratory. In such tests particular care has to be taken to reproduce the surgical field conditions. The innovative technique to produce specific phantoms and the dedicated testing protocols is described in detail.

preprint2015arXiv

Polycrystalline para-terphenyl scintillator adopted in a $β^-$ detecting probe for radio-guided surgery

A radio-guided surgery technique exploiting $β^-$ emitters is under development. It aims at a higher target-to-background activity ratio implying both a smaller radiopharmaceutical activity and the possibility of extending the technique to cases with a large uptake of surrounding healthy organs. Such technique requires a dedicated intraoperative probe detecting $β^-$ radiation. A first prototype has been developed relying on the low density and high light yield of the diphenylbutadiene doped para-therphenyl organic scintillator. The scintillation light produced in a cylindrical crystal, 5 mm in diameter and 3 mm in height, is guided to a photo-multiplier tube by optical fibres. The custom readout electronics is designed to optimize its usage in terms of feedback to the surgeon, portability and remote monitoring of the signal. Tests show that with a radiotracer activity comparable to those administered for diagnostic purposes the developed probe can detect a 0.1 ml cancerous residual of meningioma in a few seconds.

preprint2014arXiv

The ArduSiPM a compact trasportable Software/Hardware Data Acquisition system for SiPM detector

The acquisition of a single Silicon Photomultiplier require multiple and expensive electronics modules as : preamplifier, discriminator, bias voltage power supply, temperature monitor, Scalers, Analog to Digital Converter and Time to Digital Converter . The developed ArduSiPM is a compact cost effective and easily replicable Hardware software module for SiPM detector readout. The ArduSiPM uses an Arduino DUE (an open Software/Hardware board based on an ARM Cortex-M3 microcontroller) as processor board and a piggyback custom designed board (Shield), these are controlled by custom developed software and interface. The Shield contains different electronics features both to monitor, to set and to acquire the SiPM signals using the microcontroller board. The shield embed a controlled bias voltage power supply, a fast voltage preamplifier, a programmable fast discriminator to generate over threshold digital pulse , a peak hold to measure the pulse height, a temperature monitor system, a scaler to monitor over threshold rate and arrival time of the pulses. A TCP/IP Wi-Fi or Ethernet connection is used both to control and to acquire the ArduSiPM remotely with either a PC software or a Tablet APP (depending on the application).

preprint2014arXiv

Towards a Radio-guided Surgery with $β^{-}$ Decays: Uptake of a somatostatin analogue (DOTATOC) in Meningioma and High Grade Glioma

A novel radio guided surgery (RGS) technique for cerebral tumors using $β^{-}$ radiation is being developed. Checking the availability of a radio-tracer that can deliver a $β^{-}$ emitter to the tumor is a fundamental step in the deployment of such technique. This paper reports a study of the uptake of 90Y labeled (DOTATOC) in the meningioma and the high grade glioma (HGG) and a feasibility study of the RGS technique in these cases.