Researcher profile

Florian Mueller

Florian Mueller contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2023arXiv

Near-field coded-mask technique and its potential for proton therapy monitoring

Objective. Prompt-gamma imaging encompasses several approaches for online monitoring of beam range or deposited dose distribution in proton therapy. We test one of the imaging techniques - a coded mask approach - both experimentally and via simulations. Approach. Two imaging setups have been investigated experimentally. Each of them comprised a structured tungsten collimator in a form of a MURA mask and a LYSO:Ce scintillation detector of fine granularity. The setups differed in the detector dimensions and the operation mode (1D or 2D imaging). A series of measurements with radioactive sources have been conducted, testing the setups' performance of near-field gamma imaging. Additionally, Monte Carlo simulations of a larger setup of the same type were conducted, investigating its performance with a realistic gamma source distribution occurring during proton therapy. Main results. The images of point-like sources reconstructed from two smallscale prototypes' data using the MLEM algorithm constitute the experimental proof of principle for the near-field coded-mask imaging modality, both in the 1D and the 2D mode. Their precision allowed us to calibrate out certain systematic offsets appearing due to the misalignment of setup elements. The simulation of the full-scale setup yielded a mean distal falloff retrieval precision of 0.72 mm in the studies for beam energy range 89.5-107.9 MeV and with 1x10^8 protons (typical number for single distal spots). The implemented algorithm of image reconstruction is relatively fast - a typical procedure needs several seconds. Significance. Coded-mask imaging appears a valid option for proton therapy monitoring. The results of simulations let us conclude that the proposed fullscale setup is competitive to the knife-edge-shaped and the multiparalell slit cameras investigated by other groups.

preprint2022arXiv

Evaluation of semi-monolithic scintillators with integrated RF shielding material for a higher integration of PET/MRI systems

The integration of PET into MRI to form a hybrid system requires often compromises for both subsystems. For example, the integration might come at the cost of a reduced PET detector height or a reduced MRI examination volume diameter. Here, we propose a so-called shared-volume concept to use the volume required for both subsystems more efficiently, in which the MR transparency of the scintillator is exploited by integrating the RF shielding into the scintillator of the PET detector. Semi-monolithic scintillator prototypes (PVC slabs) of 7 mm and 12 mm height with integrated copper foil between every and every other slab, respectively, were investigated to evaluate the shielding effectiveness (SE). The SE was measured with probes on a test bench system. In addition, the PET detector performance was evaluated by determining the positioning using gradient tree boosting, energy and timing resolution using digital SiPM arrays (DPC3200, PDPC) in three LYSO scintillator configurations: ESR separation (Slab$\mathrm{_{ESR}}$), ESR with copper foil in between (Slab$\mathrm{_{ESR+Cu}}$), and purely copper foil separation (Slab$\mathrm{_{Cu}}$). The prototype with shielding between each slab and 12 mm height showed the highest SE with 31 dB (mean) in combination with a supporting frame. While Slab$\mathrm{_{Cu}}$ was best for positioning, followed by Slab$\mathrm{_{ESR}}$ and Slab$\mathrm{_{ESR+Cu}}$, the Slab$\mathrm{_{ESR}}$ had the best energy resolution (10.6 %), followed by Slab$\mathrm{_{ESR+Cu}}$ (11.2 %) and Slab$\mathrm{_{Cu}}$ (12.6 %). For the timing resolution, Slab$\mathrm{_{ESR}}$ and Slab$\mathrm{_{Cu}}$ achieved 279 ps and 288 ps, respectively. Slab$\mathrm{_{ESR+Cu}}$ performed worst (293 ps). The scintillator-based RF shielding shows good RF shielding with similar PET performance, demonstrating the potential for more effective integration of PET detectors into MRI systems.