Source author record

F. Volmer

F. Volmer appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

7works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2022arXiv

Charge-induced artifacts in non-local spin transport measurements: How to prevent spurious voltage signals

To conduct spin-sensitive transport measurements, a non-local device geometry is often used to avoid spurious voltages that are caused by the flow of charges. However, in the vast majority of reported non-local spin valve, Hanle spin precession, or spin Hall measurements background signals have been observed that are not related to spins. We discuss seven different types of these charge-induced signals and explain how these artifacts can result in erroneous or misleading conclusions when falsely attributed to spin transport. The charge-driven signals can be divided into two groups: Signals that are inherent to the device structure and/or the measurement setup and signals that depend on a common-mode voltage. We designed and built a voltage-controlled current source that significantly diminishes all spurious voltage signals of the latter group in both DC and AC measurements by creating a virtual ground within the non-local detection circuit. This is especially important for lock-in-based measurement techniques, where a common-mode voltage can create a phase-shifted, frequency-dependent signal with an amplitude several orders of magnitude larger than the actual spin signal. Measurements performed on graphene-based non-local spin valve devices demonstrate how all spurious voltage signals that are caused by a common-mode voltage can be completely suppressed by such a current source.

preprint2022arXiv

CVD bilayer graphene spin valves with 26 $μ$m spin diffusion length at room temperature

We present inverted spin-valves fabricated from CVD-grown bilayer graphene (BLG) that show more than a doubling in device performance at room temperature compared to state-of-the art bilayer graphene spin-valves. This is made possible by a PDMS droplet-assisted full-dry transfer technique that compensates for previous process drawbacks in device fabrication. Gate-dependent Hanle measurements show spin lifetimes of up to 5.8 ns and a spin diffusion length of up to 26 $μ$m at room temperature combined with a charge carrier mobility of $\approx$ 24 000 cm$^{2}$(Vs)$^{-1}$ for the best device. Our results demonstrate that CVD-grown BLG shows equally good room temperature spin transport properties as both CVD-graphene and even exfoliated single-layer graphene.

preprint2020arXiv

How the dynamic of photo-induced gate screening complicates the investigation of valley physics in 2D materials

An in-depth analysis of valley physics in 2D materials like transition metal dichalcogenides requires the measurement of many material properties as a function of Fermi level position within the electronic band structure. This is normally done by changing the charge carrier density of the 2D material via the gate electric field effect. Here, we show that a comparison of gate-dependent measurements, which were acquired under different measurement conditions can encounter significant problems due to the temporal evolution of the charging of trap states inside the dielectric layer or at its interfaces. The impact of, e.g., the gate sweep direction and the sweep rate on the overall gate dependence gets especially prominent in optical measurements due to photo-excitation of donor and acceptor states. Under such conditions the same nominal gate-voltage may lead to different gate-induced charge carrier densities and, hence, Fermi level positions. We demonstrate that a current flow from or even through the dielectric layer via leakage currents can significantly diminish the gate tunability in optical measurements of 2D materials.

preprint2015arXiv

Spin and charge transport in graphene-based spin transport devices with Co/MgO spin injection and spin detection electrodes

In this review we discuss spin and charge transport properties in graphene-based single-layer and few-layer spin-valve devices. We give an overview of challenges and recent advances in the field of device fabrication and discuss two of our fabrication methods in more detail which result in distinctly different device performances. In the first class of devices, Co/MgO electrodes are directly deposited onto graphene which results in rough MgO-to-Co interfaces and favor the formation of conducting pinholes throughout the MgO layer. We show that the contact resistance area product (R$_c$A) is a benchmark for spin transport properties as it scales with the measured spin lifetime in these devices indicating that contact-induced spin dephasing is the bottleneck for spin transport even in devices with large R$_c$A values. In a second class of devices, Co/MgO electrodes are first patterned onto a silicon substrate. Subsequently, a graphene-hBN heterostructure is directly transferred onto these prepatterned electrodes which provides improved interface properties. This is seen by a strong enhancement of both charge and spin transport properties yielding charge carrier mobilities exceeding 20000 cm$^2$/(Vs) and spin lifetimes up to 3.7 ns at room temperature. We discuss several shortcomings in the determination of both quantities which complicates the analysis of both extrinsic and intrinsic spin scattering mechanisms. Furthermore, we show that contacts can be the origin of a second charge neutrality point in gate dependent resistance measurements which is influenced by the quantum capacitance of the underlying graphene layer.

preprint2014arXiv

Contact-induced charge contributions to non-local spin transport measurements in Co/MgO/graphene devices

Recently, it has been shown that oxide barriers in graphene-based non-local spin-valve structures can be the bottleneck for spin transport. The barriers may cause spin dephasing during or right after electrical spin injection which limit spin transport parameters such as the spin lifetime of the whole device. An important task is to evaluate the quality of the oxide barriers of both spin injection and detection contacts in a fabricated device. To address this issue, we discuss the influence of spatially inhomogeneous oxide barriers and especially conducting pinholes within the barrier on the background signal in non-local measurements of graphene/MgO/Co spin-valve devices. By both simulations and reference measurements on devices with non-ferromagnetic electrodes, we demonstrate that the background signal can be caused by inhomogeneous current flow through the oxide barriers. As a main result, we demonstrate the existence of charge accumulation next to the actual spin accumulation signal in non-local voltage measurements, which can be explained by a redistribution of charge carriers by a perpendicular magnetic field similar to the classical Hall effect. Furthermore, we present systematic studies on the phase of the low frequency non-local ac voltage signal which is measured in non-local spin measurements when applying ac lock-in techniques. This phase has so far widely been neglected in the analysis of non-local spin transport. We demonstrate that this phase is another hallmark of the homogeneity of the MgO spin injection and detection barriers. We link backgate dependent changes of the phase to the interplay between the capacitance of the oxide barrier to the quantum capacitance of graphene.

preprint2014arXiv

Suppression of contact-induced spin dephasing in graphene/MgO/Co spin-valve devices by successive oxygen treatments

By successive oxygen treatments of graphene non-local spin-valve devices we achieve a gradual increase of the contact resistance area products ($R_cA$) of Co/MgO spin injection and detection electrodes and a transition from linear to non-linear characteristics in the respective differential dV-dI-curves. With this manipulation of the contacts both spin lifetime and amplitude of the spin signal can significantly be increased by a factor of seven in the same device. This demonstrates that contact-induced spin dephasing is the bottleneck for spin transport in graphene devices with small $R_cA$ values. With increasing $R_cA$ values, we furthermore observe the appearance of a second charge neutrality point (CNP) in gate dependent resistance measurements. Simultaneously, we observe a decrease of the gate voltage separation between the two CNPs. The strong enhancement of the spin transport properties as well as the changes in charge transport are explained by a gradual suppression of a Co/graphene interaction by improving the oxide barrier during oxygen treatment.

preprint2013arXiv

Role of MgO barriers for spin and charge transport in Co/MgO/graphene non-local spin-valve devices

We investigate spin and charge transport in both single and bilayer graphene non-local spin-valve devices. Similar to previous studies on bilayer graphene, we observe an inverse dependence of the spin lifetime on the carrier mobility in our single layer devices. This general trend is only observed in devices with large contact resistances. Furthermore, we observe a second Dirac peak in devices with long spin lifetimes. This results from charge transport underneath the contacts. In contrast, all devices with low ohmic contact resistances only exhibit a single Dirac peak. Additionally, the spin lifetime is significantly reduced indicating that an additional spin dephasing occurs underneath the electrodes.