Source author record

F. Ulrich-Pur

F. Ulrich-Pur appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2021arXiv

Single particle tracking uncertainties in ion imaging

An extensive comparison of the path uncertainty in single particle tracking systems for ion imaging was carried out based on Monte Carlo simulations. The spatial resolution as function of system parameters such as geometry, detector properties and the energy of proton and helium beams was investigated to serve as a guideline for hardware developments. Primary particle paths were sampled within a water volume and compared to the most likely path estimate obtained from detector measurements, yielding a depth-dependent uncertainty envelope. The maximum uncertainty along this curve was converted to a conservative estimate of the minimal radiographic pixel spacing for a single set of parameter values. Simulations with various parameter settings were analysed to obtain an overview of the reachable pixel spacing as function of system parameters. The results were used to determine intervals of detector material budget and position resolution that yield a pixel spacing small enough for clinical dose calculation. To ensure a pixel spacing below 2 mm, the material budget of a detector should remain below 0.25 % for a position resolution of 200 $\mathrm{μm}$ or below 0.75 % for a resolution of 10 $\mathrm{μm}$. Using protons, a sub-millimetre pixel size could not be achieved for a phantom size of 300 mm or at a large clearance. With helium ions, a sub-millimetre pixel spacing could be achieved even for a large phantom size and clearance, provided the position resolution was less than 100 $\mathrm{μm}$ and material budget was below 0.75 %.

preprint2020arXiv

Imaging with protons at MedAustron

Ion beam therapy has become a frequently applied form of cancer therapy over the last years. The advantage of ion beam therapy over conventional radiotherapy using photons is the strongly localized dose deposition, leading to a reduction of dose applied to surrounding healthy tissue. Currently, treatment planning for proton therapy is based on X-ray computed tomography, which entails certain sources of inaccuracy in alculation of the stopping power (SP). A more precise method to acquire the SP is to directly use high energy protons (or other ions such as carbon) and perform proton computed tomography (pCT). With this method, the ions are tracked prior to entering and after leaving the patient and finally their residual energy is measured at the very end. Therefore, an ion imaging demonstrator, comprising a tracking telescope made from double-sided silicon strip detectors and a range telescope as a residual energy detector, was set up. First measurements with this setup were performed at beam tests at MedAustron, a center for ion therapy and research in \mbox{Wiener Neustadt}, \mbox{Austria}. The facility provides three rooms for cancer treatment with proton beams as well as one which is dedicated to non-clinical research. This contribution describes the principle of ion imaging with proton beams in general as well as the design of the experimental setup. Moreover, first results from simulations and recent beam tests as well as ideas for future developments will be presented.