Researcher profile

Evgeny Hahamovich

Evgeny Hahamovich contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2020arXiv

Increased SNR in acousto-optic imaging via coded ultrasound transmission

Acousto-optic imaging (AOI) is a non-invasive method that uses acoustic modulation to map the light fluence inside biological tissue. In many AOI implementations, ultrasound pulses are used in a time-gated measurement to perform depth-resolved imaging without the need for mechanical scanning. However, to achieve high axial resolution, it is required that ultrasound pulses with few cycles are used, limiting the modulation strength. In this Letter, we developed a new approach to pulse-based AOI in which a coded ultrasound transmission is used. In coded-transmission AOI (CT-AOI), one may achieve an axial resolution that corresponds to a single cycle, but with a signal-to-noise ratio (SNR) that scales as the square root of the number of cycles. Using CT-AOI with 79 cycles, we experimentally demonstrate over 4-fold increase in SNR in comparison to a single-cycle AOI scheme.

preprint2020arXiv

Ultrasound Detection Arrays Via Coded Hadamard Apertures

In the medical fields, ultrasound detection is often performed with piezoelectric arrays that enable one to simultaneously map the acoustic fields at several positions. In this work, we develop a novel method for transforming a single-element ultrasound detector into an effective detection array by spatially filtering the incoming acoustic fields using a binary acoustic mask coded with cyclic Hadamard patterns. By scanning the mask in front of the detector, we obtain a multiplexed measurement dataset from which a map of the acoustic field is analytically constructed. We experimentally demonstrate our method by transforming a single-element ultrasound detector into 1D arrays with up to 59 elements.