Source author record

Aner Lev

Aner Lev appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Homodyne Time-Domain Acousto-Optic Imaging for Low-Gain Photodetectors

Acousto-optics imaging (AOI) is a hybrid imaging modality that is capable of mapping the light fluence rate in deep tissue by local ultrasound modulation of the diffused photons. Since the intensity of the modulated photons is relatively low, AOI systems often rely on high-gain photodetectors, e.g. photomultiplier tubes (PMTs), which limit scalability due to size and cost and may significantly increase the relative shot-noise in the detected signal due to low quantum yields or gain noise. In this Letter, we have developed a homodyne AOI scheme in which the modulated photons are amplified by interference with a reference beam, enabling their detection with low-gain photodetectors. We experimentally demonstrate our approach with a silicon photodiode, achieving over a 4-fold improvement in SNR in comparison to a PMT-based setup.

preprint2020arXiv

Increased SNR in acousto-optic imaging via coded ultrasound transmission

Acousto-optic imaging (AOI) is a non-invasive method that uses acoustic modulation to map the light fluence inside biological tissue. In many AOI implementations, ultrasound pulses are used in a time-gated measurement to perform depth-resolved imaging without the need for mechanical scanning. However, to achieve high axial resolution, it is required that ultrasound pulses with few cycles are used, limiting the modulation strength. In this Letter, we developed a new approach to pulse-based AOI in which a coded ultrasound transmission is used. In coded-transmission AOI (CT-AOI), one may achieve an axial resolution that corresponds to a single cycle, but with a signal-to-noise ratio (SNR) that scales as the square root of the number of cycles. Using CT-AOI with 79 cycles, we experimentally demonstrate over 4-fold increase in SNR in comparison to a single-cycle AOI scheme.