Source author record

Ettore Vittone

Ettore Vittone appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2014arXiv

Modeling of ion beam induced charge sharing experiments for the design of high resolution position sensitive detectors

In a multi-electrode device, the motion of free charge carriers generated by ionizing radiation induces currents on all the electrodes surrounding the active region [1]. The amount of charge induced in each sensitive electrode is a function of the device geometry, the transport parameters and the generation profile. Hence this charge sharing effect allows the signal from each sensitive electrode to provide information about the electrical characteristics of the device, as well as information on the location and the profile of each ionization track. The effectiveness of such approach was recently demonstrated in Ion Beam Induced Charge (IBIC) experiments carried out using a 2 MeV He microbeam scanning over a sub-100 lm scale silicon device, where the ion strike location point was evaluated through a comparative analysis of the charge induced in two independent surface electrodes coupled to independent data acquisition systems [2]. In this report, we show that the Monte Carlo method [3] can be efficiently exploited to simulate this IBIC experiment and to model the experimental data, shedding light on the role played by carrier diffusion, electronic noise and ion beam spot size on the induction of charge in the sensitive electrodes. Moreover, the Monte Carlo method shows that information on the ion strike position can be obtained from the charge signals from the sensitive electrodes.

preprint2013arXiv

A new diamond biosensor with integrated graphitic microchannels for detecting quantal exocytic events from chromaffin cells

The quantal release of catecholamines from neuroendocrine cells is a key mechanism which has been investigated with a broad range of materials and devices, among which carbon-based materials such as carbon fibers, diamond-like carbon, carbon nanotubes and nanocrystalline diamond. In the present work we demonstrate that a MeV-ion-microbeam lithographic technique can be successfully employed for the fabrication of an all-carbon miniaturized cellular bio-sensor based on graphitic micro-channels embedded in a single-crystal diamond matrix. The device was functionally characterized for the in vitro recording of quantal exocytic events from single chromaffin cells, with high sensitivity and signal-to-noise ratio, opening promising perspectives for the realization of monolithic all-carbon cellular biosensors.

preprint2012arXiv

Laser-induced etching of few-layer graphene synthesized by Rapid-Chemical Vapour Deposition on Cu thin films

The outstanding electrical and mechanical properties of graphene make it very attractive for several applications, Nanoelectronics above all. However a reproducible and non destructive way to produce high quality, large-scale area, single layer graphene sheets is still lacking. Chemical Vapour Deposition of graphene on Cu catalytic thin films represents a promising method to reach this goal, because of the low temperatures (T < 900 Celsius degrees) involved during the process and of the theoretically expected monolayer self-limiting growth. On the contrary such self-limiting growth is not commonly observed in experiments, thus making the development of techniques allowing for a better control of graphene growth highly desirable. Here we report about the local ablation effect, arising in Raman analysis, due to the heat transfer induced by the laser incident beam onto the graphene sample.

preprint2012arXiv

Spectroscopic measurement of the refractive index of ion-implanted diamond

We present the results of variable-angle spectroscopic ellipsometry and transmittance measurements to determine the variation of the complex refractive index of ion implanted single-crystal diamond. An increase is found in both real and imaginary parts at increasing damage densities. The index depth variation is determined in the whole wavelength range between 250 and 1690 nm. The dependence from the vacancy density is evaluated, highlighting a deviation from linearity in the high-damage-density regime. A considerable increase (up to 5%) in the real part of the index is observed, attributed to an increase in polarizability, thus offering new microfabrication possibilities for waveguides and other photonic structures in diamond.