Source author record

Eric Prieto

Eric Prieto appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2012arXiv

A spectrograph instrument concept for the Prime Focus Spectrograph (PFS) on Subaru Telescope

We describe the conceptual design of the spectrograph opto-mechanical concept for the SuMIRe Prime Focus Spectrograph (PFS) being developed for the SUBARU telescope. The SuMIRe PFS will consist of four identical spectrographs, each receiving 600 fibers from a 2400 fiber robotic positioner at the prime focus. Each spectrograph will have three channels covering in total, a wavelength range from 380 nm to 1300 nm. The requirements for the instrument are summarized in Section 1. We present the optical design and the optical performance and analysis in Section 2. Section 3 introduces the mechanical design, its requirements and the proposed concepts. Finally, the AIT phases for the Spectrograph System are described in Section 5.

preprint2012arXiv

Detectors and cryostat design for the SuMIRe Prime Focus Spectrograph (PFS)

We describe the conceptual design of the camera cryostats, detectors, and detector readout electronics for the SuMIRe Prime Focus Spectrograph (PFS) being developed for the Subaru telescope. The SuMIRe PFS will consist of four identical spectrographs, each receiving 600 fibers from a 2400 fiber robotic positioner at the prime focus. Each spectrograph will have three channels covering wavelength ranges 3800 Å - 6700 Å, 6500 Å - 10000 Å, and 9700 Å - 13000 Å, with the dispersed light being imaged in each channel by a f/1.10 vacuum Schmidt camera. In the blue and red channels a pair of Hamamatsu 2K x 4K edge-buttable CCDs with 15 um pixels are used to form a 4K x 4K array. For the IR channel, the new Teledyne 4K x 4K, 15 um pixel, mercury-cadmium-telluride sensor with substrate removed for short-wavelength response and a 1.7 um cutoff will be used. Identical detector geometry and a nearly identical optical design allow for a common cryostat design with the only notable difference being the need for a cold radiation shield in the IR camera to mitigate thermal background. This paper describes the details of the cryostat design and cooling scheme, relevant thermal considerations and analysis, and discusses the detectors and detector readout electronics.

preprint2012arXiv

Prime Focus Spectrograph - Subaru's future -

The Prime Focus Spectrograph (PFS) of the Subaru Measurement of Images and Redshifts (SuMIRe) project has been endorsed by Japanese community as one of the main future instruments of the Subaru 8.2-meter telescope at Mauna Kea, Hawaii. This optical/near-infrared multi-fiber spectrograph targets cosmology with galaxy surveys, Galactic archaeology, and studies of galaxy/AGN evolution. Taking advantage of Subaru's wide field of view, which is further extended with the recently completed Wide Field Corrector, PFS will enable us to carry out multi-fiber spectroscopy of 2400 targets within 1.3 degree diameter. A microlens is attached at each fiber entrance for F-ratio transformation into a larger one so that difficulties of spectrograph design are eased. Fibers are accurately placed onto target positions by positioners, each of which consists of two stages of piezo-electric rotary motors, through iterations by using back-illuminated fiber position measurements with a wide-field metrology camera. Fibers then carry light to a set of four identical fast-Schmidt spectrographs with three color arms each: the wavelength ranges from 0.38 μm to 1.3 μm will be simultaneously observed with an average resolving power of 3000. Before and during the era of extremely large telescopes, PFS will provide the unique capability of obtaining spectra of 2400 cosmological/astrophysical targets simultaneously with an 8-10 meter class telescope. The PFS collaboration, led by IPMU, consists of USP/LNA in Brazil, Caltech/JPL, Princeton, & JHU in USA, LAM in France, ASIAA in Taiwan, and NAOJ/Subaru.

preprint2005arXiv

An original image slicer designed for Integral Field Spectroscopy with NIRSpec/JSWT

Integral Field Spectroscopy (IFS) provides a spectrum simultaneously for each spatial sample of an extended, two-dimensional field. It consists of an Integral Field Unit (IFU) which slices and re-arranges the initial field along the entrance slit of a spectrograph. This article presents an original design of IFU based on the advanced image slicer concept. To reduce optical aberrations, pupil and slit mirrors are disposed in a fan-shaped configuration that means that angles between incident and reflected beams on each elements are minimized. The fan-shaped image slicer improves image quality in terms of wavefront error by a factor 2 comparing with classical image slicer and, furthermore it guaranties a negligible level of differential aberration in the field. As an exemple, we are presenting the design LAM used for its proposal at the NIRSPEC/IFU invitation of tender.

preprint2005arXiv

Modeling a Slicer Mirror Using Zemax User-Defined Surface

A slicer mirror is a complex surface composed by many tilted and decentered mirrors sub-surfaces. The major difficulty to model such a complex surface is the large number of parameters used to define it. The Zemax's multi-configuration mode is usually used to specify each parameters (tilts, curvatures, decenters) for each mirror sub-surface which are then considered independently. Otherwise making use of the User-Defined Surface (UDS-DLL) Zemax capability, we are able to consider the set of sub-surfaces as a whole surface. In this paper, we present such a UDS-DLL tool comparing its performance with those of the classical multi-configuration mode. In particular, we explore the use of UDS-DLL to investigate the cross-talk due to the diffraction on the slicer array mirrors which has been a burden task when using multi-configuration mode.