Source author record

Eduardo Cotilla-Sanchez

Eduardo Cotilla-Sanchez appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

14works
10topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

14 published item(s)

preprint2021arXiv

A Coupled Karhunen--Loève and Anisotropic Sparse Grid Interpolation Method for the Probabilistic Load Flow Problem

In the traditional load flow analysis, a key assumption is that the input variables, i.e., generator output and customer demand, are fixed in time and the associated response has no variability. This assumption, however, is no longer valid as the adoption of renewable energy resources add more variability and uncertainty to the modern electrical system. Addressing these concerns is the definition of the Probabilistic Load Flow (PLF) problem. The challenge of the PLF problem lies in handling high-dimensional input uncertainties and the non-linearity of the load flow equations. The most straightforward way to address these problems, but at the cost of computational time, is to perform a Monte Carlo method. This work, however, solves these problems -- accuracy, high-dimensionality, and computational time -- with a coupled Karhunen-Loève (KL) expansion and Anisotropic Sparse Grid algorithm. The proposed method is implemented and tested on the IEEE 118-bus test system and a modernized version of the IEEE Reliability Test System - 1996, the Reliability Test System - Grid Modernization Lab Consortium (RTS-GMLC). Results for the 194-dimensional case show a decrease in computational time when compared to the 10,000 sample Monte Carlo method given a bound on mean and standard deviation error.

preprint2021arXiv

On PMU Data Integrity under GPS Spoofing Attacks: A Sparse Error Correction Framework

Consider the problem of mitigating the impact on data integrity of phasor measurement units (PMUs) given a GPS spoofing attack. We present a sparse error correction framework to treat PMU measurements that are potentially corrupted due to a GPS spoofing attack. We exploit the sparse nature of a GPS spoofing attack, which is that only a small fraction of PMUs are affected by the attack. We first present attack identifiability conditions (in terms of network topology, PMU locations, and the number of spoofed PMUs) under which data manipulation by the spoofing attack is identifiable. The identifiability conditions have important implications on how the locations of PMUs affect their resilience to GPS spoofing attacks. To effectively correct spoofed PMU data, we present a sparse error correction approach wherein computation tasks are decomposed into smaller zones to ensure scalability. We present experimental results obtained from numerical simulations with the IEEE RTS-96 and IEEE 300 test networks to demonstrate the effectiveness of the proposed approach.

preprint2021arXiv

Rapid Method for Generation Prioritization during System Restoration with Renewable Resources

Quick and reliable power system restoration is critically important after natural disasters or other sudden threats, such as cyber-attacks. Leveraging renewable resources in system restoration shortens recovery times, resulting in prevented life-loss and avoided economic-loss, and improves the resilience of the entire grid. However, it is not a common practice today; the inherent variability of these resources represents a challenge for a streamlined restoration process. This paper presents a prioritized method - starting with renewable generator units then lowering priority to conventional units - to plan the operational schedule of a power system during the restoration process. The goal is to achieve a well balanced system in the presence of significant renewable penetration. Validation and benchmarking experiments were performed on a customized version of the RTS-GMLC test system using six months out of year-long data, tested through hourly simulations. After evaluating the performance and computational costs, this method proved faster than common approaches: a MILP Unit Commitment algorithm, widely used today, and an "enable-and-try" algorithm. In summary, herein a more convenient method is provided to be utilized during time-sensitive restoration, as an online operation-planning aid.

preprint2021arXiv

Relaxation Based Modeling of GMD Induced Cascading Failures in PowerModelsGMD.jl

A major risk of geomagnetic disturbances (GMDs) is cascading failure of electrical grids. The modeling of GMD events and cascading outages in power systems is difficult, both independently and jointly, because of the many different mechanisms and physics involved. This paper introduces a relaxation based modeling of GMD-induced cascading failures:~the dc approximation-based DCSIMSEP solver was adapted to simulate cascading as a result of GMDs, the full set of ac power flow equations were relaxed to guarantee optimality, and the reactive power losses were modeled while keeping the problem convex. The developed algorithm was implemented in PowerModelsGMD.jl - an open-source software specifically designed to model and analyze geomagnetic hazards - and demonstrated to work on the RTS-GMLC-GIC-EAST synthetic test network.

preprint2020arXiv

Defending Against Adversarial Attacks in Transmission- and Distribution-level PMU Data

Phasor measurement units (PMUs) provide high-fidelity data that improve situation awareness of electric power grid operations. PMU datastreams inform wide-area state estimation, monitor area control error, and facilitate event detection in real time. As PMU data become more available and increasingly reliable, these devices are found in new roles within control systems, such as remedial action schemes and early warning detection systems. As with other cyber physical systems, maintaining data integrity and security pose a significant challenge for power system operators. In this paper, we present a comprehensive analysis of multiple machine learning techniques to detect malicious data injection within PMU data streams. The two datasets used in this study come from two PMU networks: an inter-university, research-grade distribution network spanning three institutions in the U.S. Pacific Northwest, and a utility transmission network from the Bonneville Power Administration. We implement the detection algorithms with TensorFlow, an open-source software library for machine learning, and the results demonstrate potential for distributing the training workload and achieving higher performance, while maintaining effectiveness in the detection of spoofed data.

preprint2016arXiv

A Backend Framework for the Efficient Management of Power System Measurements

Increased adoption and deployment of phasor measurement units (PMU) has provided valuable fine-grained data over the grid. Analysis over these data can provide insight into the health of the grid, thereby improving control over operations. Realizing this data-driven control, however, requires validating, processing and storing massive amounts of PMU data. This paper describes a PMU data management system that supports input from multiple PMU data streams, features an event-detection algorithm, and provides an efficient method for retrieving archival data. The event-detection algorithm rapidly correlates multiple PMU data streams, providing details on events occurring within the power system. The event-detection algorithm feeds into a visualization component, allowing operators to recognize events as they occur. The indexing and data retrieval mechanism facilitates fast access to archived PMU data. Using this method, we achieved over 30x speedup for queries with high selectivity. With the development of these two components, we have developed a system that allows efficient analysis of multiple time-aligned PMU data streams.

preprint2015arXiv

A Network-of-Networks Model for Electrical Infrastructure Networks

Modeling power transmission networks is an important area of research with applications such as vulnerability analysis, study of cascading failures, and location of measurement devices. Graph-theoretic approaches have been widely used to solve these problems, but are subject to several limitations. One of the limitations is the ability to model a heterogeneous system in a consistent manner using the standard graph-theoretic formulation. In this paper, we propose a {\em network-of-networks} approach for modeling power transmission networks in order to explicitly incorporate heterogeneity in the model. This model distinguishes between different components of the network that operate at different voltage ratings, and also captures the intra and inter-network connectivity patterns. By building the graph in this fashion we present a novel, and fundamentally different, perspective of power transmission networks. Consequently, this novel approach will have a significant impact on the graph-theoretic modeling of power grids that we believe will lead to a better understanding of transmission networks.

preprint2015arXiv

Dynamic Modeling of Cascading Failure in Power Systems

The modeling of cascading failure in power systems is difficult because of the many different mechanisms involved; no single model captures all of these mechanisms. Understanding the relative importance of these different mechanisms is an important step in choosing which mechanisms need to be modeled for particular types of cascading failure analysis. This work presents a dynamic simulation model of both power networks and protection systems, which can simulate a wider variety of cascading outage mechanisms, relative to existing quasi-steady state (QSS) models. The model allows one to test the impact of different load models and protections on cascading outage sizes. This paper describes each module of the developed dynamic model and demonstrates how different mechanisms interact. In order to test the model we simulated a batch of randomly selected $N-2$ contingencies for several different static load configurations, and found that the distribution of blackout sizes and event lengths from the proposed dynamic simulator correlates well with historical trends. The results also show that load models have significant impacts on the cascading risks. This dynamic model was also compared against a QSS model based on the dc power flow approximations; we find that the two models largely agree, but produce substantially different results for later stages of cascading.

preprint2015arXiv

Fast Sequence Component Analysis for Attack Detection in Synchrophasor Networks

Modern power systems have begun integrating synchrophasor technologies into part of daily operations. Given the amount of solutions offered and the maturity rate of application development it is not a matter of "if" but a matter of "when" in regards to these technologies becoming ubiquitous in control centers around the world. While the benefits are numerous, the functionality of operator-level applications can easily be nullified by injection of deceptive data signals disguised as genuine measurements. Such deceptive action is a common precursor to nefarious, often malicious activity. A correlation coefficient characterization and machine learning methodology are proposed to detect and identify injection of spoofed data signals. The proposed method utilizes statistical relationships intrinsic to power system parameters, which are quantified and presented. Several spoofing schemes have been developed to qualitatively and quantitatively demonstrate detection capabilities.

preprint2014arXiv

A Policy Switching Approach to Consolidating Load Shedding and Islanding Protection Schemes

In recent years there have been many improvements in the reliability of critical infrastructure systems. Despite these improvements, the power systems industry has seen relatively small advances in this regard. For instance, power quality deficiencies, a high number of localized contingencies, and large cascading outages are still too widespread. Though progress has been made in improving generation, transmission, and distribution infrastructure, remedial action schemes (RAS) remain non-standardized and are often not uniformly implemented across different utilities, ISOs, and RTOs. Traditionally, load shedding and islanding have been successful protection measures in restraining propagation of contingencies and large cascading outages. This paper proposes a novel, algorithmic approach to selecting RAS policies to optimize the operation of the power network during and after a contingency. Specifically, we use policy-switching to consolidate traditional load shedding and islanding schemes. In order to model and simulate the functionality of the proposed power systems protection algorithm, we conduct Monte-Carlo, time-domain simulations using Siemens PSS/E. The algorithm is tested via experiments on the IEEE-39 topology to demonstrate that the proposed approach achieves optimal power system performance during emergency situations, given a specific set of RAS policies.

preprint2013arXiv

Calculation of the Autocorrelation Function of the Stochastic Single Machine Infinite Bus System

Critical slowing down (CSD) is the phenomenon in which a system recovers more slowly from small perturbations. CSD, as evidenced by increasing signal variance and autocorrelation, has been observed in many dynamical systems approaching a critical transition, and thus can be a useful signal of proximity to transition. In this paper, we derive autocorrelation functions for the state variables of a stochastic single machine infinite bus system (SMIB). The results show that both autocorrelation and variance increase as this system approaches a saddle-node bifurcation. The autocorrelation functions help to explain why CSD can be used as an indicator of proximity to criticality in power systems revealing, for example, how nonlinearity in the SMIB system causes these signs to appear.

preprint2013arXiv

Understanding early indicators of critical transitions in power systems from autocorrelation functions

Many dynamical systems, including power systems, recover from perturbations more slowly as they approach critical transitions---a phenomenon known as critical slowing down. If the system is stochastically forced, autocorrelation and variance in time-series data from the system often increase before the transition, potentially providing an early warning of coming danger. In some cases, these statistical patterns are sufficiently strong, and occur sufficiently far from the transition, that they can be used to predict the distance between the current operating state and the critical point. In other cases CSD comes too late to be a good indicator. In order to better understand the extent to which CSD can be used as an indicator of proximity to bifurcation in power systems, this paper derives autocorrelation functions for three small power system models, using the stochastic differential algebraic equations (SDAE) associated with each. The analytical results, along with numerical results from a larger system, show that, although CSD does occur in power systems, its signs sometimes appear only when the system is very close to transition. On the other hand, the variance in voltage magnitudes consistently shows up as a good early warning of voltage collapse. Finally, analytical results illustrate the importance of nonlinearity to the occurrence of CSD.

preprint2011arXiv

Comparing the Topological and Electrical Structure of the North American Electric Power Infrastructure

The topological (graph) structure of complex networks often provides valuable information about the performance and vulnerability of the network. However, there are multiple ways to represent a given network as a graph. Electric power transmission and distribution networks have a topological structure that is straightforward to represent and analyze as a graph. However, simple graph models neglect the comprehensive connections between components that result from Ohm's and Kirchhoff's laws. This paper describes the structure of the three North American electric power interconnections, from the perspective of both topological and electrical connectivity. We compare the simple topology of these networks with that of random (Erdos and Renyi, 1959), preferential-attachment (Barabasi and Albert, 1999) and small-world (Watts and Strogatz, 1998) networks of equivalent sizes and find that power grids differ substantially from these abstract models in degree distribution, clustering, diameter and assortativity, and thus conclude that these topological forms may be misleading as models of power systems. To study the electrical connectivity of power systems, we propose a new method for representing electrical structure using electrical distances rather than geographic connections. Comparisons of these two representations of the North American power networks reveal notable differences between the electrical and topological structure of electric power networks.

preprint2010arXiv

Do topological models provide good information about vulnerability in electric power networks?

In order to identify the extent to which results from topological graph models are useful for modeling vulnerability in electricity infrastructure, we measure the susceptibility of power networks to random failures and directed attacks using three measures of vulnerability: characteristic path lengths, connectivity loss and blackout sizes. The first two are purely topological metrics. The blackout size calculation results from a model of cascading failure in power networks. Testing the response of 40 areas within the Eastern US power grid and a standard IEEE test case to a variety of attack/failure vectors indicates that directed attacks result in larger failures using all three vulnerability measures, but the attack vectors that appear to cause the most damage depend on the measure chosen. While our topological and power grid model results show some trends that are similar, there is only a mild correlation between the vulnerability measures for individual simulations. We conclude that evaluating vulnerability in power networks using purely topological metrics can be misleading.