Source author record

E. N. Alexeyev

E. N. Alexeyev appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2015arXiv

Results of a search for daily and annual variations of the Po-214 half-life at the two year observation period

The brief description of installation TAU-2 intended for long-term monitoring of the half-life value $τ$ ($τ_{1/2}$) of the $^{214}$Po is presented. The methods of measurement and processing of collected data are reported. The results of analysis of time series values $τ$ with different time step are presented. Total of measurement time was equal to 590 days. Averaged value of the $^{214}$Po half-life was obtained $τ=163.46\pm0.04$ $μ$s. The annual variation with an amplitude $A=(8.9\pm2.3)\cdot10^{-4}$, solar-daily variation with an amplitude $A_{So}=(7.5\pm1.2)\cdot10^{-4}$, lunar-daily variation with an amplitude $A_L=(6.9\pm2.0)\cdot10^{-4}$ and sidereal-daily variation with an amplitude $A_S=(7.2\pm1.2)\cdot10^{-4}$ were found in a series of $τ$ values. The maximal values of amplitude are observed at the moments when the projections of the installation Earth location velocity vectors toward the source of possible variation achieve its maximal magnitudes.

preprint2014arXiv

Sources of the systematic errors in measurements of Po-214 decay half-life time variations at the Baksan deep underground experiments

The design changes of the Baksan low-background TAU-1 and TAU-2 set-ups allowed to improve a sensitivity of Po-214 half-life (τ) measurements up to the 2.5 x 10^{-4} are described. Different possible sources of systematic errors influencing on the $τ$-value are studed. An annual variation of Po-214 half-life time measurements with an amplitude of A=(6.9 \pm 3) x 10^{-4} and a phase of (ϕ=93 \pm 10) days was found in a sequence of the week-collected τ-values obtained from the TAU-2 data sample with total duration of 480 days. 24 hours' variation of the τ-value measurements with an amplitude of A=(10.0 \pm 2.6) x 10^{-4} and phase of (ϕ=1 \pm 0.5) hours was found in a solar day 1 hour step τ-value sequence formed from the same data sample. It was found that the Po-214 half-life averaged at 480 days is equal to (163.45 \pm 0.04) mks.

preprint2011arXiv

Experimental test of the time stability of the half-life of alpha-decay Po-214 nuclei

A method and results of an experimental test of the time stability of the half-life of alpha-decay Po-214 nuclei are presented. Two underground installations aimed at monitoring the time stability have been constructed. Time of measurement exceeds 1038 days for one set up and 562 days for the other. It was found that amplitude of possible annual variation of Po-214 half-life does not exceed 0.2% of the mean value. The limit on the deviation of the decay curve from exponent at 0.034\times T_{1/2}<t< 0.1\times T_{1/2} range has been found.