Source author record

Dorota Sobczynska

Dorota Sobczynska appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
2topics
2close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2016arXiv

Influence of the proton initiated at most two electromagnetic sub-cascades events on IACT observations

The efficiency of the $γ$/hadron separation worsens significantly at low energies for Imaging Air Cherenkov Telescopes (IACT). This observed effect was partially explained by the occurrence of a hardly reducible hadronic background (i.e. detected images that are formed mainly by the light from a single electromagnetic or a single $π^0$ sub-cascade in the proton induced shower) [1,2]. IACTs also record events containing Cherenkov light from at most two electromagnetic sub-cascades, which don't have to be products of single $π^0$ decay in the hadron initiated showers. In this paper, the impact of at most two electromagnetic sub-cascades events on the primary $γ$-ray selection was studied using the Monte Carlo simulations. We investigate how the total fraction of at most two sub-cascades events in the expected total protonic background depends on the hadron interaction models (GHEISHA and FLUKA), trigger threshold, reflector area and altitude of the observatory. We show that the efficiency of the $γ$/hadron separation is anti-correlated with the contribution of at most two electromagnetic sub-cascades events in the proton initiated showers below 200 GeV. The influence of at most two electromagnetic sub-cascades events on the $γ$-ray selection is similar to the effect of the single electromagnetic sub-cascade and singe $π^0$ events in IACT observations. The occurrence of all these images in the data collected by IACTs reduces the efficiency of the $γ$/hadron separation at low energies.

preprint2015arXiv

The role of the hadron initiated single electromagnetic subcascades in IACT observations

The sensitivity of Imaging Air Cherenkov Telescopes (IACTs) worsens significantly at low energies because the gamma/hadron separation becomes much more complex. In this paper we study the impact of the single electromagnetic subcascade events on the efficiency of the gamma/hadron separation for a system of four IACTs using Monte Carlo simulations. The studies are done for: two different altitudes of the observatory, three different telescope sizes and two hadron interaction models (GHEISHA and FLUKA). More than 90% of the single electromagnetic proton-induced subcascade events are showers with primary energy below 200 GeV, regardless on the trigger threshold. The estimated efficiency of the gamma/hadron separation using the FLUKA model is similar to results obtained using the GHEISHA model. Nevertheless, for at least one triggered telescope only, a higher fraction of single electromagnetic subcascade events was obtained from the FLUKA model. Finally, the calculated quality factors are anti-correlated with the contributions of the false gamma-ray events in the proton initiated showers. Therefore, the occurrence of single electromagnetic subcascade events is one of the main reasons of the worsening of the primary gamma-ray selection efficiency at low energies.

preprint2014arXiv

Influence of clouds on the parameters of images measured by IACT at very high energies

Observations with the Cherenkov telescopes are in principle limited to the clear sky conditions due to significant absorption of Cherenkov light by clouds. If the cloud level is high enough or the atmospheric transmission of the cloud is high, then high energy showers (with TeV energies) can still produce enough Cherenkov photons allowing detection by telescopes with large sizes and cameras with large field of view (FOV). In this paper we study the possibility of observations of showers, induced by high energy particles in the atmosphere, in the presence of clouds which are completely or partially opaque for Cherenkov radiation. We show how the image parameters of the Cherenkov light distribution on the telescope camera are influenced for different opacity and altitude of the cloud. By applying the Monte Carlo simulations, we calculate the scaled LENGTH and WIDTH parameters with the purpose to separate gamma-ray and proton initiated showers in real data. We show, that the high level of the night sky background effects the selection efficiency of the gamma-ray initiated showers. However, application of the higher image cleaning level significantly improves expected quality factors. The estimated gamma-ray selection efficiency for the detector with the camera FOV limited to 8 deg. is slightly better than for the camera with unlimited FOV, although the number of identified gamma-ray events is lower. We conclude that large Cherenkov telescopes with large FOV cameras can be used for observations of very high energy gamma-rays in the presence of clouds. Consequently, the amount of useful data can be significantly enlarged.

preprint2009arXiv

Limits to the energy resolution of a single Air Cherenkov Telescope at low energies

The photon density on the ground is a fundamental quantity in all experiments based on Cherenkov light measurements, e.g. in the Imaging Air Cherenkov Telescopes (IACT). IACT's are commonly and successfully used in order to search and study Very High Energy (VHE) gamma-ray sources. Difficulties with separating primary photons from primary hadrons (mostly protons) in Cherenkov experiments become larger at lower energies. I have calculated longitudinal and lateral density distributions and their fluctuations at low energies basing on Monte Carlo simulations (for vertical gamma cascades and protonic showers) to check the influence of the detector parameters on the possible measurement. Relative density fluctuations are significantly higher in proton than in photon induced showers. Taking into account the limited detector field of view (FOV) implies the changes of these calculated distributions for both types of primary particles and causes an enlargement in relative fluctuations. Absorption due to Rayleigh and Mie scattering has an impact on mean values but does not change relative fluctuations. The total number of Cherenkov photons is more sensitive to the observation height in gamma cascades than in proton showers at low primary energies. The relative fluctuations of the density do not depend on the reflector size in the investigated size range (from 240 m^2 up to 960 m^2). This implies that a single telescope with a mirror area larger than that of the MAGIC telescope cannot achieve better energy resolution than estimated and presented in this paper. The correlations between longitudinal and lateral distributions are much more pronounced for primary gamma-ray than for primary proton showers.

preprint2009arXiv

The background from single electromagnetic subcascades for a stereo system of air Cherenkov telescopes

The MAGIC experiment, a very large Imaging Air Cherenkov Telescope (IACT) with sensitivity to low energy (E < 100 GeV) VHE gamma rays, has been operated since 2004. It has been found that the gamma/hadron separation in IACTs becomes much more difficult below 100 GeV [Albert et al 2008] A system of two large telescopes may eventually be triggered by hadronic events containing Cherenkov light from only one electromagnetic subcascade or two gamma subcascades, which are products of the single pi^0 decay. This is a possible reason for the deterioration of the experiment's sensitivity below 100 GeV. In this paper a system of two MAGIC telescopes working in stereoscopic mode is studied using Monte Carlo simulations. The detected images have similar shapes to that of primary gamma-rays and they have small sizes (mainly below 400 photoelectrons (p.e.)) which correspond to an energy of primary gamma-rays below 100 GeV. The background from single or two electromagnetic subcascdes is concentrated at energies below 200 GeV. Finally the number of background events is compared to the number of VHE gamma-ray excess events from the Crab Nebula. The investigated background survives simple cuts for sizes below 250 p.e. and thus the experiment's sensitivity deteriorates at lower energies.